Literature DB >> 30230096

Diffusion Tensor Imaging of the Calf Muscles in Subjects With and Without Diabetes Mellitus.

Masoud Edalati1, Mary K Hastings2, Christopher J Sorensen2, Mohamed Zayed3, Michael J Mueller2, Charles F Hildebolt1, Jie Zheng1.   

Abstract

BACKGROUND: Diffusion tensor imaging (DTI) has been used to characterize calf skeletal muscle architecture.
PURPOSE: To assess the diffusional properties of the calf muscles of subjects with and without diabetes, at rest and during isometric plantarflexion exercise. STUDY TYPE: Prospective.
SUBJECTS: Twenty-six subjects in two groups: 13 healthy and 13 subjects with type 2 diabetes (DM); each group consisted of seven females and six males. FIELD STRENGTH/SEQUENCE: 3T/2D single-shot spin echo planar imaging. ASSESSMENT: Fractional anisotropy (FA), mean diffusivity (MD), diffusion eigenvalues, and fiber tracking indices were obtained from the medial gastrocnemius (MG), lateral gastrocnemius (LG), and soleus (SOL) muscles of the calf at rest and during isometric plantarflexion exercise. STATISTICAL TESTS: We used a combination of nonparametric (Wilcoxon) and parametric (t-test) statistical assessments.
RESULTS: The medial gastrocnemius muscle had more indices with significant differences between the two groups (six indices with P < 0.05) than did the lateral gastrocnemius (three indices with P < 0.05) and soleus muscles (only one index with P < 0.05). While the healthy group showed elevated MD values from rest to exercise (MG = 5.83%, LG = 13.45%, and SOL = 11.68%), the diabetic MD showed higher increases (MG = 19.74%, LG = 29.31%, and SOL = 20.84%) that were different between groups (MG: P = 0.009, LG: P = 0.037, and SOL: P = 0.049). DATA
CONCLUSION: Our results indicate considerable diffusional changes between healthy subjects and subjects with diabetes at rest and during isometric plantarflexion exercise in the calf muscles. The medial gastrocnemius muscle displayed the most diffusion sensitivity to diabetes-related microstructural changes. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1285-1295.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Year:  2018        PMID: 30230096      PMCID: PMC6424658          DOI: 10.1002/jmri.26286

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  1 in total

1.  Normal values and test-retest variability of stimulated-echo diffusion tensor imaging and fat fraction measurements in the muscle.

Authors:  Matthew Farrow; Andrew J Grainger; Ai Lyn Tan; Maya H Buch; Paul Emery; John P Ridgway; Thorsten Feiweier; Steven F Tanner; John Biglands
Journal:  Br J Radiol       Date:  2019-07-12       Impact factor: 3.039

  1 in total