Literature DB >> 30229255

Remarkable difference in Al3+ and Zn2+ sensing properties of quinoline based isomers.

Ananta Hazra1, Ankita Roy, Abhishek Mukherjee, Guru Prasad Maiti, Partha Roy.   

Abstract

Two positional isomers, 4-methyl-2-((quinolin-6-ylimino)methyl)phenol (6-QMP) and 4-methyl-2-((quinolin-2-ylimino)methyl)phenol (2-QMP), have been synthesized to compare their fluorescence sensing properties. 6-QMP and 2-QMP have been synthesized by Schiff-base condensation between 2-hydroxy-5-methylbenzaldehyde and the respective amine (6-aminoquinoline for 6-QMP and 2-aminoquinoline for 2-QMP) under mild conditions. These compounds have been characterized by standard methods. 6-QMP and 2-QMP have been found to be dual fluorescence chemosensors for Al3+ and Zn2+ ions but the increment of fluorescence intensity varies. 6-QMP can detect Al3+ (emission at 543 nm) and Zn2+ (emission at 525 nm) by the enhancement of emission intensity by 97 and 79 fold, respectively, with the same excitation wavelength at 415 nm. However, 2-QMP shows two different excitation and emission wavelengths for the detection of Al3+ (emission at 376 nm; λex = 330 nm) and Zn2+ (emission at 550 nm; λex = 435 nm). The increase in emission intensity is low (4.5 fold for Al3+ and 35 fold for Zn2+) compared to that with 6-QMP. The enhancement of intensity may be explained by the PET mechanism. Both the probes form a 1 : 1 complex with both the metal ions as indicated by the elemental and different spectral analysis. 6-QMP shows better sensitivity towards both the metal ions than 2-QMP. Both the probes are able to detect Al3+ and Zn2+ ions by producing distinct color changes that can be observed by the naked eye. Some theoretical calculations have been performed to investigate spectral transitions of the probes along with their aluminum and zinc compounds. These compounds have been used for living cell imaging studies. A comparison with the recently published studies has been made.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30229255     DOI: 10.1039/c8dt02856g

Source DB:  PubMed          Journal:  Dalton Trans        ISSN: 1477-9226            Impact factor:   4.390


  6 in total

1.  An antipyrine based fluorescent probe for distinct detection of Al3+ and Zn2+ and its AIEE behaviour.

Authors:  Samir Maity; Milan Shyamal; Rakesh Maity; Naren Mudi; Paresh Hazra; Prabhat Kr Giri; Shashanka Shekhar Samanta; Santanu Pyne; Ajay Misra
Journal:  Photochem Photobiol Sci       Date:  2020-05-20       Impact factor: 3.982

2.  Designed Synthesis of Fluorescence 'Turn-on' Dual Sensor for Selective Detection of Al3+ and Zn2+ in Water.

Authors:  Naren Mudi; Paresh Hazra; Milan Shyamal; Samir Maity; Prabhat Kumar Giri; Shashanka Shekhar Samanta; Debkumar Mandal; Ajay Misra
Journal:  J Fluoresc       Date:  2021-01-06       Impact factor: 2.217

3.  Aggregation-Induced Emission-Active Hydrazide-Based Probe: Selective Sensing of Al3+, HF2 -, and Nitro Explosives.

Authors:  Sunanda Dey; Rakesh Purkait; Kunal Pal; Kuladip Jana; Chittaranjan Sinha
Journal:  ACS Omega       Date:  2019-05-14

4.  Photophysical, photostability, and ROS generation properties of new trifluoromethylated quinoline-phenol Schiff bases.

Authors:  Inaiá O Rocha; Yuri G Kappenberg; Wilian C Rosa; Clarissa P Frizzo; Nilo Zanatta; Marcos A P Martins; Isadora Tisoco; Bernardo A Iglesias; Helio G Bonacorso
Journal:  Beilstein J Org Chem       Date:  2021-12-01       Impact factor: 2.883

5.  Pyridine-pyrazole based Al(iii) 'turn on' sensor for MCF7 cancer cell imaging and detection of picric acid.

Authors:  Sayan Saha; Avik De; Arijit Ghosh; Avik Ghosh; Kaushik Bera; Krishna Sundar Das; Sohel Akhtar; Nakul C Maiti; Abhijit Kumar Das; Benu Brata Das; Raju Mondal
Journal:  RSC Adv       Date:  2021-03-09       Impact factor: 3.361

6.  a Versatile Schiff Base Chemosensor for the Determination of Trace Co2+, Ni2+, Cu2+, and Zn2+ in the Water and Its Bioimaging Applications.

Authors:  Hongmei Liu; Shangli Ding; Quan Lu; Yue Jian; Gang Wei; Zeli Yuan
Journal:  ACS Omega       Date:  2022-02-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.