Literature DB >> 30226124

Effectiveness of ultraviolet disinfection in reducing hospital-acquired Clostridium difficile and vancomycin-resistant Enterococcus on a bone marrow transplant unit.

Jennifer Brite1, Tracy McMillen1, Elizabeth Robilotti1, Janet Sun1, Hoi Yan Chow1, Frederic Stell2, Susan K Seo3, Donna McKenna4, Janet Eagan1, Marisa Montecalvo5, Donald Chen5, Kent Sepkowitz3, Mini Kamboj1.   

Abstract

OBJECTIVE: To determine the effectiveness of ultraviolet (UV) environmental disinfection system on rates of hospital-acquired vancomycin-resistant enterococcus (VRE) and Clostridium difficile.
DESIGN: Using active surveillance and an interrupted time-series design, hospital-acquired acquisition of VRE and C. difficile on a bone marrow transplant (BMT) unit were examined before and after implementation of terminal disinfection with UV on all rooms regardless of isolation status of patients. The main outcomes were hospital-based acquisition measured through (1) active surveillance: admission, weekly, and discharge screening for VRE and toxigenic C. difficile (TCD) and (2) clinical surveillance: incidence of VRE and CDI on the unit.
SETTING: Bone marrow transplant unit at a tertiary-care cancer center.ParticipantsStem cell transplant (SCT) recipients.InterventionTerminal disinfection of all rooms with UV regardless of isolation status of patients.
RESULTS: During the 20-month study period, 579 patients had 704 admissions to the BMT unit, and 2,160 surveillance tests were performed. No change in level or trend in the incidence of VRE (trend incidence rate ratio [IRR], 0.96; 95% confidence interval [CI], 0.81-1.14; level IRR, 1.34; 95% CI, 0.37-1.18) or C. difficile (trend IRR, 1.08; 95% CI, 0.89-1.31; level IRR, 0.51; 95% CI, 0.13-2.11) was observed after the intervention.
CONCLUSIONS: Utilization of UV disinfection to supplement routine terminal cleaning of rooms was not effective in reducing hospital-acquired VRE and C. difficile among SCT recipients.

Entities:  

Mesh:

Year:  2018        PMID: 30226124     DOI: 10.1017/ice.2018.215

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  4 in total

Review 1.  Hospital surface disinfection using ultraviolet germicidal irradiation technology: A review.

Authors:  Robert Scott; Lovleen Tina Joshi; Conor McGinn
Journal:  Healthc Technol Lett       Date:  2022-05-28

Review 2.  Systematic review on use, cost and clinical efficacy of automated decontamination devices.

Authors:  Stephanie J Dancer; Marco-Felipe King
Journal:  Antimicrob Resist Infect Control       Date:  2021-02-12       Impact factor: 4.887

Review 3.  Impact of environmental hygiene interventions on healthcare-associated infections and patient colonization: a systematic review.

Authors:  Alexandra Peters; Marie N Schmid; Pierre Parneix; Dan Lebowitz; Marlieke de Kraker; Julien Sauser; Walter Zingg; Didier Pittet
Journal:  Antimicrob Resist Infect Control       Date:  2022-02-19       Impact factor: 4.887

4.  Ultraviolet-C Light Evaluation as Adjunct Disinfection to Remove Multidrug-Resistant Organisms.

Authors:  Clare Rock; Yea Jen Hsu; Melanie S Curless; Karen C Carroll; Tracy Ross Howard; Kathryn A Carson; Stephanie Cummings; Michael Anderson; Aaron M Milstone; Lisa L Maragakis
Journal:  Clin Infect Dis       Date:  2022-08-24       Impact factor: 20.999

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.