Literature DB >> 30221932

Multiplex On-Bead Isotope Dimethyl Labeling Coupled with Liquid Chromatography-High-Resolution Mass Spectrometry for Quantitative Analysis of Sulfonamides in Estuarine Ice.

Minghuo Wu1, Lin Fu1, Yufeng Hu1, Jingyun Su1, Siyuan Jing1, Hao Zhou1, Jingjing Zhan1.   

Abstract

A multiplex-on-bead-isotope-dimethyl-labeling method was developed for the quantitative analysis of sulfonamides (SAs) in environmental water samples by liquid chromatography-high-resolution mass spectrometry (LC-HRMS). In this method, five samples could be labeled in parallel with different isotope reagents and quantified in a single LC-HRMS analysis. Magnetic solid-phase extraction (MSPE) was employed in the sample preparation to concentrate the trace-level analytes by using lab-synthesized magnetic carbon nanospheres (MCNSs). After the analytes were captured on the MCNSs, the isotope labeling was performed directly by dispersing the MCNSs in the reaction buffer (on-bead labeling). The experimental conditions for MSPE and labeling were systematically investigated. For the tested 12 SAs, a labeling efficiency of over 99% could be achieved within 20 min. The LC-HRMS separation, including equilibration, could be achieved in 6 min. By combining MSPE (enriched 200-fold), multiplex on-bead dimethyl labeling, and LC-HRMS, all the tested SAs could be reliably quantified with limits of detection (LODs) of 0.1-5 ng/L. This method was verified using fortified pond water spiked with 12 SAs (0.01-5 μg/L), and accuracies of 81-106% were achieved with good reproducibility (RSD < 10%, n = 3), which confirmed its applicability in real-sample analysis. With this method, ice samples collected at the estuary of the Daliao River in northeast China were analyzed; nine SAs (sulfanilamide, sulfapyridine, sulfamethazine, sulfamethizole, sulfachloropyridazine, sulfamethoxypyridazine, sulfameter, sulfathiazole, and sulfisoxazole) were detected at concentrations of 0-85 ng/L, and the total concentrations were in the range of 185-402 ng/L with a median value of 274 ng/L.

Entities:  

Year:  2018        PMID: 30221932     DOI: 10.1021/acs.analchem.8b03220

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  1 in total

1.  Net-like mesoporous carbon nanocomposites for magnetic solid-phase extraction of sulfonamides prior to their quantitation by UPLC-HRMS.

Authors:  Siyuan Di; Jing Yu; Pin Chen; Gangtian Zhu; Shukui Zhu
Journal:  Mikrochim Acta       Date:  2020-01-09       Impact factor: 5.833