Literature DB >> 30220068

Allergy to Surgical Implants.

Karin A Pacheco1,2.   

Abstract

Surgical implants are essential elements of repair procedures to correct worn out joints, damaged spinal components, heart and vascular disease, and chronic pain. However, many of the materials that provide stability, flexibility, and durability to the implants are also immunogenic. Fortunately, allergic responses to surgical implants are infrequent. When they do occur, however, the associated pain, swelling, inflammation, and decreased range of motion can significantly impair the implant function. Given the high numbers of joint replacements performed in the developed world, allergic reactions to orthopedic implants form the largest category of allergic responses. The most important allergens in this category include nickel, cobalt, chromium, and bone cement. These allergens are also the most important in reactions to spinal surgeries. Multiple cardiac and neurostimulatory devices are constructed of metals and adhesives that can be sensitizing in some individuals. Implantable pulse generators, important in cardiac pacemakers, gastric stimulators, and neurostimulators, may include components made of stainless steel, titanium alloy, platinum and iridium, epoxy resins, poly methyl methacrylates, and isocyanates, all of which are immunogenic in some patients. Cardiac stents and patches are often made of Nitinol, a composite of nickel and titanium. More surgical procedures are closed using skin glues, which are also capable of triggering a blistering contact dermatitis. Patch testing is the gold standard to determine sensitization, and this review provides a list of standard allergens to test for different implants. The patients most appropriate for testing include (1) pre-operative joint replacement patients with a prior history of skin reactions to metal jewelry, jean snaps, watch bands, metal glass frames, artificial nails, or skin glue; (2) post-operative joint replacement failure patients needing revision without an obvious cause such as infection or mechanical incompatibility; and (3) post-operative cardiac or neurological patients with localized rash, pain, swelling, or inflammation near or over the implant.

Entities:  

Keywords:  Adhesive allergy; Contact dermatitis; Joint failure; Joint replacement; Metal allergy; Methyl methacrylate; Nickel; Rash; Surgical implant

Mesh:

Substances:

Year:  2019        PMID: 30220068     DOI: 10.1007/s12016-018-8707-y

Source DB:  PubMed          Journal:  Clin Rev Allergy Immunol        ISSN: 1080-0549            Impact factor:   8.667


  12 in total

1.  Hydrothermally treated titanium surfaces for enhanced osteogenic differentiation of adipose derived stem cells.

Authors:  Vignesh K Manivasagam; Ketul C Popat
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2021-07-14

Review 2.  Metallic Implants Used in Lumbar Interbody Fusion.

Authors:  Jakub Litak; Michał Szymoniuk; Wojciech Czyżewski; Zofia Hoffman; Joanna Litak; Leon Sakwa; Piotr Kamieniak
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

3.  Histomorphometry of Ossification in Functionalised Ceramics with Tripeptide Arg-Gly-Asp (RGD): An In Vivo Study.

Authors:  Filippo Migliorini; Hanno Schenker; Nicola Maffulli; Frank Hildebrand; Jörg Eschweiler
Journal:  Life (Basel)       Date:  2022-05-20

4.  Second-generation trabecular micro-bypass stent implantation: Retrospective analysis after 12- and 24-month follow-up.

Authors:  Raphael Neuhann; Tobias Neuhann
Journal:  Eye Vis (Lond)       Date:  2020-01-10

Review 5.  Utility of Patch Testing and Lymphocyte Transformation Testing in the Evaluation of Metal Allergy in Patients with Orthopedic Implants.

Authors:  Logan J Richards; Alexandra Streifel; Jonathan M Rodrigues
Journal:  Cureus       Date:  2019-09-25

6.  Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery.

Authors:  David Manning
Journal:  Ophthalmol Ther       Date:  2019-08-17

7.  The T Cell Repertoires from Nickel Sensitized Joint Implant Failure Patients.

Authors:  Lan Chen; Yan Zhang; Karin Pacheco; Shaodong Dai
Journal:  Int J Mol Sci       Date:  2021-02-28       Impact factor: 5.923

8.  Epidural Effusion as Allergic Reaction Following Polyetheretherketone Cranioplasty: An Illustrative Case and Review of the Literature.

Authors:  Lisa B Shields; Meena Vessell; Ian S Mutchnick
Journal:  Cureus       Date:  2022-01-18

Review 9.  Contact Dermatitis: Classifications and Management.

Authors:  Yan Li; Linfeng Li
Journal:  Clin Rev Allergy Immunol       Date:  2021-07-15       Impact factor: 8.667

10.  Corrosion Resistance of Graphene oxide/Silver Coatings on Ni-Ti alloy and Expression of IL-6 and IL-8 in Human Oral Fibroblasts.

Authors:  Viritpon Srimaneepong; Dinesh Rokaya; Pasutha Thunyakitpisal; Jiaqian Qin; Kanokwan Saengkiettiyut
Journal:  Sci Rep       Date:  2020-02-24       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.