Surpass Flow Diverter in the Treatment of Ruptured Intracranial Aneurysms-A Single-Center Experience.

Anshu Mahajan1, Biplab Das1, Karanjit Singh Narang2, Ajaya Nand Jha2, Varindera Paul Singh2, Harsh Sapra3, Gaurav Goel4.   

Abstract

BACKGROUND: Use of a Surpass flow diverter (FD) device in the treatment of acutely ruptured aneurysm has not been well studied and reported in the literature.
METHODS: We retrospectively reviewed patients with subarachnoid hemorrhage who were treated by Surpass FD placement at our hospital between June 2016 and March 2018. Detailed analysis of medical records was performed to obtain patient age, gender, clinical history, Hunt and Hess grade, Fisher grade, results of radiographic and procedural details including technical success and complication, clinical outcome, and follow-up angiographic results.
RESULTS: Our search identified 16 patients with 16 aneurysms who were treated with Surpass FD, of which 13 aneurysms (81%) were in the anterior circulation and 3 (19%) were in the posterior circulation. Aneurysm size ranged from 1.1 to 16 mm, with a mean of 4 mm. The mean delay between subarachnoid hemorrhage and endovascular treatment was 5 days (range, 3-20 days). Only 1 Surpass FD was used in each patient, ranging in size from 3 × 25 mm to 4 × 50 mm. Fifteen patients (94%) achieved favorable clinical outcome (modified Rankin Scale score 0-1) at 3 months. One patient died of invasive fungal infection. Angiographic follow-up results were assessed by O'Kelly-Marotta grading scale in 15 surviving patients and showed a grade D result (no filling) in 13/15 aneurysms (87%) at 3 and 6 months.
CONCLUSIONS: A Surpass FD device is a feasible option for the treatment of ruptured intracranial aneurysms that are difficult to treat by conventional clipping and coiling; however, larger and comparative studies with long-term follow-up are needed to confirm its safety and efficacy.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Angiography internal carotid artery; Basilar artery; Coiling; Flow diverter; Ruptured aneurysm; Vertebral artery

Mesh:

Year:  2018        PMID: 30213677     DOI: 10.1016/j.wneu.2018.09.011

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  2 in total

1.  Ruptured Basilar Artery Dissection Diagnosed Using Magnetic Resonance Vessel Wall Imaging and Treated with Coil Embolization with Overlapping LVIS Stents: A Case Report.

Authors:  Shinya Sonobe; Masahiro Yoshida; Kuniyasu Niizuma; Teiji Tominaga
Journal:  NMC Case Rep J       Date:  2020-03-24

Review 2.  Outcomes after Flow Diverter Treatment in Subarachnoid Hemorrhage: A Meta-Analysis and Development of a Clinical Prediction Model (OUTFLOW).

Authors:  Michelle F M Ten Brinck; Viktoria E Shimanskaya; René Aquarius; Ronald H M A Bartels; Frederick J A Meijer; Petra C Koopmans; Guido de Jong; Ajay K Wakhloo; Joost de Vries; Hieronymus D Boogaarts
Journal:  Brain Sci       Date:  2022-03-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.