Literature DB >> 30213673

Posterior C2 Fixation Using Trans-C2 Inferior Articular Process Screws: A Case Series and Technical Note.

Rui Zong1, Teng Li1, Lenian Lu2, Guangyu Qiao1, Xinguang Yu3.   

Abstract

OBJECTIVE: Upper cervical fixation with C2 pedicle screw insertion may predispose patients to vertebral artery injury, in particular, patients with craniovertebral junction anomalies. The aim of this study was to describe an alternative technique with trans-C2 inferior articular process screw (C2IAPS) insertion for rigid C2 fixation, which can be used to anchor the C2 vertebra for upper cervical fixation.
METHODS: Records of 19 patients who underwent posterior atlantoaxial fixation using C2IAPS combined with C1 lateral mass screw were retrospectively reviewed. Efficacy was assessed by postoperative imaging and Japanese Orthopaedic Association scores.
RESULTS: There were 22 C2IAPSs successfully implanted (3 on both sides and 16 on 1 side). With the exception of 2 screws that had intruded into the outlet of the intervertebral foramen, all screws were safely implanted. Average Japanese Orthopaedic Association scores improved from 11.8 ± 1.9 preoperatively to 15.3 ± 1.3 postoperatively. Bony fusion rate was 100%.
CONCLUSIONS: For patients who are not eligible for C2 pedicle screw fixation, C2IAPS fixation can be considered as an alternative technique for upper cervical fixation of C2.
Copyright © 2018. Published by Elsevier Inc.

Entities:  

Keywords:  Atlantoaxial dislocation; Atlantoaxial instability; C1 lateral mass screw; C2 pedicle screw; Congenital craniovertebral anomalies; Trans-C2 inferior articular process screw; Vertebral artery injury

Mesh:

Year:  2018        PMID: 30213673     DOI: 10.1016/j.wneu.2018.09.014

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  3 in total

1.  A novel surgical protocol for safe and accurate placement of C1 lateral mass screws in patients with atlas assimilation, basilar invagination and atlantoaxial instability: technical details, accuracy assessment and perioperative complications.

Authors:  Yue-Qi Du; Yi-Heng Yin; Teng Li; Guang-Yu Qiao; Xin-Guang Yu
Journal:  Eur Spine J       Date:  2021-03-11       Impact factor: 3.134

2.  Can C1 lateral mass and C3 pedicle screw fixation be used as an option for atlantoaxial reduction and stabilization in Klippel-Feil patients? A study of its morphological feasibility, technical nuances, and clinical efficiency.

Authors:  Yue-Qi Du; Yi-Heng Yin; Teng Li; Guang-Yu Qiao; Xin-Guang Yu
Journal:  Neurosurg Rev       Date:  2022-01-13       Impact factor: 3.042

3.  Treatment of Reducible Atlantoaxial Dislocation and Basilar Invagination Using the Head Frame Reduction Technique and Atlantoaxial Arthrodesis.

Authors:  Teng Li; Yue-Qi Du; Yi-Heng Yin; Shao-Ling Xing; Guang-Yu Qiao
Journal:  Global Spine J       Date:  2020-11-03