Literature DB >> 30213364

Is there a difference in clinical outcomes and repair integrity between arthroscopic single-row versus transosseous (anchorless) fixation? A retrospective comparative study.

Raffaele Garofalo1, Roberto Calbi2, Alessandro Castagna3, Eugenio Cesari4, Aydin Budeyri5, Sumant G Krishnan6.   

Abstract

BACKGROUND: Few studies have investigated clinical and structural outcomes after transosseous (TO) repair. The purpose of this study was to compare structural and clinical outcomes of rotator cuff tear, repaired arthroscopically, with a single row (SR) or transossoeus (TO) anchorless technique.
METHODS: 96 patients who underwent an arthroscopic repair for superior or posterosuperior rotator cuff tear using TO (n:54) or a SR (n:42) were retrospectively enrolled in this study after evaluation of clinical and surgical notes. Functional evaluation was performed with the adjusted Constant score, and American Shoulder and Elbow Surgeons (ASES) score. Postoperative cuff integrity was determined through MRI study.
RESULTS: Patients were recalled after a minimum follow-up of two years. All the patients were available for the study. In the SR group the Constant rating system showed a significant improvement from a preoperative average rating of 44.8 to an average of 85.7. In the group of TO repair the Constant rating system showed a significant improvement from a preoperative average of 46.1 to an average of 87.6 postoperatively. According to ASES index scores, the average total score improved from 42.8 to 92.0 in the anchor group and from 40.4 to 94.6 in the TO group. There was no statistical difference between the two groups about clinical outcomes. Postoperative MRI revealed no differences in term of complete re-tears between the two techniques. In the SR group at MRI we observe significant more cases of rotator cuff with a Sugaya type III healing.
CONCLUSIONS: Arthroscopic rotator cuff repair yielded successful clinical outcomes using SR and TO technique. However using the TO technique we saw less type 3 Sugaya readings on MRI suggesting a possible benefit with TO repair. LEVEL OF EVIDENCE II: Retrospective study.
Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30213364     DOI: 10.1016/j.jos.2018.05.011

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  3 in total

1.  Arthroscopic, Needle-Based, Transosseous Rotator Cuff Repair.

Authors:  Ehud Atoun; Liam T Kane; Joseph A Abboud
Journal:  Arthrosc Tech       Date:  2019-12-18

2.  Needle-Based Arthroscopic Transosseous Rotator Cuff Repair: A Short-Term Outcomes Analysis.

Authors:  Ehud Atoun; John G Horneff; Ofer Levy; Walter Stanwood; Nikhil Verma; Joseph A Abboud
Journal:  Cureus       Date:  2021-02-27

3.  Comparative efficacy of 5 suture configurations for arthroscopic rotator cuff tear repair: a network meta-analysis.

Authors:  Wei Wang; Hui Kang; Hongchuan Li; Jian Li; Yibin Meng; Peng Li
Journal:  J Orthop Surg Res       Date:  2021-12-11       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.