Literature DB >> 30212800

Utility of virtual monoenergetic images derived from a dual-layer detector-based spectral CT in the assessment of aortic anatomy and pathology: A retrospective case control study.

Hamid Chalian1, Kevin Kalisz2, Negin Rassouli3, Amar Dhanantwari4, Prabhakar Rajiah5.   

Abstract

OBJECTIVES: To evaluate the ability of the retrospectively generated virtual monoenergetic images (VMIs) from a dual-layer detector-based spectral computed tomography (SDCT) to augment aortic enhancement for the evaluation of aortic anatomy and pathology.
METHODS: 98 patients with suboptimal aortic enhancement (≤200 HU) were retrospectively identified from SDCT scans. VMI from 40 to 80 keV were generated. Attenuation, noise, SNR, and CNR were measured at seven levels in the aorta. Image quality was graded on a 5-point scale, 5 being the best. From the VMI, an ideal set was chosen with mean vascular attenuation above 200 HU while maintaining diagnostic quality. Image parameters and quality of this ideal-set were compared to the standard 120-kVp images.
RESULTS: The mean attenuation of all seven measured anatomical regions was 156.6 ± 61.7 HU in the 120-kVp images. Attenuation of the VMI from 40 to 70 keV were higher than the 120-kVp image, measuring 439.2 ± 215.3 HU, 298.5 ± 140.6 HU, 213.4 ± 94.3 HU, and 164.7 ± 90.2 HU, for 40 keV, 50 keV, 60 keV, and 70 keV, respectively (p value <0.01 for 40, 50, 60 keV; 0.07 for 70 keV). SNR and CNR showed similar trends. The 50 keV VMI had the best image quality (4.48 ± 0.84 vs. 2.24 ± 0.92 on 120-kVp images, p < 0.001). Attenuation, CNR, and SNR increased by 90.6%, 85.0%, and 108.1% at 50 keV compared to 120-kVp.
CONCLUSIONS: A contrast-enhanced CT study can be optimized for the assessment of the aorta by using low-energy VMI obtained using SDCT. At the optimal monoenergetic level, attenuation, SNR, CNR and image quality were significantly higher than that of conventional polyenergetic images.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aorta; CTA; Dual layered; Enhancement; Monoenergetic

Mesh:

Year:  2018        PMID: 30212800     DOI: 10.1016/j.clinimag.2018.08.007

Source DB:  PubMed          Journal:  Clin Imaging        ISSN: 0899-7071            Impact factor:   1.605


  2 in total

1.  Dual-layer spectral computerized tomography for metal artifact reduction: small versus large orthopedic devices.

Authors:  Christos Kosmas; Mojgan Hojjati; Peter C Young; Aidin Abedi; Ali Gholamrezanezhad; Prabhakar Rajiah
Journal:  Skeletal Radiol       Date:  2019-06-01       Impact factor: 2.199

2.  Myocardial Late Iodine Enhancement and Extracellular Volume Quantification with Dual-Layer Spectral Detector Dual-Energy Cardiac CT.

Authors:  Seitaro Oda; Takafumi Emoto; Takeshi Nakaura; Masafumi Kidoh; Daisuke Utsunomiya; Yoshinori Funama; Yasunori Nagayama; Seiji Takashio; Mitsuharu Ueda; Taro Yamashita; Kenichi Tsujita; Yukio Ando; Yasuyuki Yamashita
Journal:  Radiol Cardiothorac Imaging       Date:  2019-04-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.