Literature DB >> 30212667

Sensitive detection of telomerase activity in cancer cells using portable pH meter as readout.

Lixu Wang1, Chaoqun Chen1, Huawei Huang1, Da Huang2, Fang Luo3, Bin Qiu1, Longhua Guo4, Zhenyu Lin1, Huanghao Yang1.   

Abstract

This study developed a portable and sensitive biosensor for the detection of telomerase activity extracted from HeLa cells by monitoring urease regulated pH change. In the presence of telomerase, the telomerase substrate (TS) primer was elongated by adding telomeric repeats (TTAGGG)n firstly. The TS primer was then immobilized onto streptavidin magnesphere paramagnetic particles (PMPs). The elongated repeat unit can hybridize with biotinylated complementary DNA (cDNA) to specifically capture biotinylated urease onto PMPs. After magnetic separation, the PMPs complex was mixed with urea solution. As urease can catalyze the hydrolysis of urea into ammonia and induce pH increasing of the solution, the activity of telomerase can be detected by pH-sensitive dyes or by a portable pH meter easily. The changed pH has a linear relationship with the logarithm of the number of HeLa cells from 50 to 10,000 and with a detection limit of ~20 HeLa cells, which indicated the proposed method have potential application in telomerase-related cancer diagnosis.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bromocresol purple; HeLa cell; Telomerase; Urease; pH meter

Mesh:

Substances:

Year:  2018        PMID: 30212667     DOI: 10.1016/j.bios.2018.08.069

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Metal-ion-induced DNAzyme on magnetic beads for detection of lead(II) by using rolling circle amplification, glucose oxidase, and readout of pH changes.

Authors:  Dianping Tang; Biyun Xia; Ying Tang; Jin Zhang; Qian Zhou
Journal:  Mikrochim Acta       Date:  2019-05-02       Impact factor: 5.833

2.  A turn-on graphene quantum dot and graphene oxide based fluorometric aptasensor for the determination of telomerase activity.

Authors:  Elahe Kazemi; Habib Bagheri; Dariush Norouzian
Journal:  Mikrochim Acta       Date:  2019-11-15       Impact factor: 5.833

3.  Immunoassay for pathogenic bacteria using platinum nanoparticles and a hand-held hydrogen detector as transducer. Application to the detection of Escherichia coli O157:H7.

Authors:  Sheng-Jun Bu; Kui-Yu Wang; Hua-Song Bai; Yan Leng; Chuan-Jing Ju; Cheng-Yu Wang; Wen-Sen Liu; Jia-Yu Wan
Journal:  Mikrochim Acta       Date:  2019-04-23       Impact factor: 5.833

4.  Translating in vitro diagnostics from centralized laboratories to point-of-care locations using commercially-available handheld meters.

Authors:  JingJing Zhang; Tian Lan; Yi Lu
Journal:  Trends Analyt Chem       Date:  2019-12-23       Impact factor: 12.296

  4 in total