| Literature DB >> 30211797 |
D Anitha, Karupppasamy Subburaj, Felix K Kopp1, Kai Mei1, Peter Foehr2, Rainer Burgkart2, Nico Sollmann3, Christian Maegerlein3, Jan S Kirschke3, Peter B Noel1, Thomas Baum3.
Abstract
Statistical iterative reconstruction (SIR) using multidetector computed tomography (MDCT) is a promising alternative to standard filtered back projection (FBP), because of lower noise generation while maintaining image quality. Hence, we investigated the feasibility of SIR in predicting MDCT-based bone mineral density (BMD) and vertebral bone strength from finite element (FE) analysis. The BMD and FE-predicted bone strength derived from MDCT images reconstructed using standard FBP (FFBP) and SIR with (FSIR) and without regularization (FSIRB0) were validated against experimental failure loads (Fexp). Statistical iterative reconstruction produced the best quality images with regard to noise, signal-to-noise ratio, and contrast-to-noise ratio. Fexp significantly correlated with FFBP, FSIR, and FSIRB0. FFBP had a significant correlation with FSIRB0 and FSIR. The BMD derived from FBP, SIRB0, and SIR were significantly correlated. Effects of regularization should be further investigated with FE and BMD analysis to allow for an optimal iterative reconstruction algorithm to be implemented in an in vivo scenario.Entities:
Mesh:
Year: 2019 PMID: 30211797 DOI: 10.1097/RCT.0000000000000788
Source DB: PubMed Journal: J Comput Assist Tomogr ISSN: 0363-8715 Impact factor: 1.826