Literature DB >> 30205683

Sensitive Screening Method for Determination of Pyrethroids in Chicken Eggs and Various Meat Samples by Gas Chromatography and Electron Capture Detection.

Valeria Nardelli1, Francesco Casamassima1, Giuseppe Gesualdo1, Donghao Li2, Wadir M V Marchesiello3, Donatella Nardiello3, Maurizio Quinto2,3.   

Abstract

A sensitive and reproducible screening analytical method is described for the determination of six pyrethroids (phenothrin, permethrin, cyfluthrin, cypermethrin, deltamethrin, fenvalerate) in egg and meat samples by gas chromatography and electron capture detection (GC-ECD). A fast cleanup procedure, based on solid-phase extraction has been used, ensuring reduced solvent consumption and time and allowing the simultaneous preparation of multiple sample extracts. Under the optimal chromatographic conditions, an efficient separation was obtained with a total analysis time of less than 60 min, including the extraction-purification steps. Good responses for the six pyrethroids were obtained in a range of 50-500 μg L-1, with linear coefficients higher than 0.9992. Instrumental limits of detection were between 0.22 and 0.63 μg L-1, corresponding to 0.04 and 0.13 μg kg-1 in the matrix. Detection limits in chicken eggs and various meat samples, calculated on spiked samples, were in the range 0.05-0.25 μg kg-1 and 0.07-0.23 μg kg-1, respectively. The validation results confirmed that the proposed GC-ECD method can be used as a reliable screening tool for the determination of pyrethroids in official check analyses. The method was extensively validated following the European directives, demonstrating its conformity in terms of selectivity, sensitivity, recovery, precision, and measurement uncertainty.

Entities:  

Keywords:  chicken eggs; gas chromatography/electron capture detection; meat; pyrethroids; validation

Mesh:

Substances:

Year:  2018        PMID: 30205683     DOI: 10.1021/acs.jafc.8b04851

Source DB:  PubMed          Journal:  J Agric Food Chem        ISSN: 0021-8561            Impact factor:   5.279


  2 in total

1.  A Microfluidic Paper-Based Analytical Device for Type-II Pyrethroid Targets in an Environmental Water Sample.

Authors:  Sumate Pengpumkiat; Jintana Nammoonnoy; Watcharaporn Wongsakoonkan; Pajaree Konthonbut; Pornpimol Kongtip
Journal:  Sensors (Basel)       Date:  2020-07-23       Impact factor: 3.576

2.  Magnetic solid-phase extraction of pyrethroid insecticides from tea infusions using ionic liquid-modified magnetic zeolitic imidazolate framework-8 as an adsorbent.

Authors:  Xiaodong Huang; Yanan Liu; Huifang Liu; Guangyang Liu; Xiaomin Xu; Lingyun Li; Jun Lv; Haixiang Gao; Donghui Xu
Journal:  RSC Adv       Date:  2019-11-29       Impact factor: 4.036

  2 in total