Literature DB >> 30205338

Modeling emerging contaminants breakthrough in packed bed adsorption columns by UV absorbance and fluorescing components of dissolved organic matter.

Massimiliano Sgroi1, Tarun Anumol2, Paolo Roccaro1, Federico G A Vagliasindi1, Shane A Snyder3.   

Abstract

This study investigated, using rapid small-scale column testing, the breakthrough of dissolved organic matter (DOM) and eleven emerging organic contaminants (EOCs) during granular activated carbon (GAC) filtration of different water qualities, including wastewater, surface water and synthetic water (riverine organic matter dissolved in deionized water). Fluorescing organic matter was better adsorbed than UV absorbance at 254 nm (UV254) and dissolved organic carbon (DOC) in all tested water. Furthermore, highest adsorption of DOM (in terms of DOC, UV254 and fluorescence) was observed during wastewater filtration. UV absorbing DOM had fast and similar breakthrough in surface water and synthetic water, whereas fluorescence breakthrough was very rapid only in synthetic water. PARAFAC modeling showed that different fluorescing components were differently adsorbed during GAC process. Particularly, fluorescing components with maxima intensity at higher excitation wavelengths, which are corresponding to humic-like fluorescence substances, were better removed than other components in all waters. As opposed to DOM, EOCs were better adsorbed during synthetic water filtration, whereas the fastest EOCs breakthrough was observed during filtration of wastewater, which was the water that determined the highest carbon fouling. Exception was represented by long-chained perfluoroalkylated substances (i.e., PFOA, PFDA and PFOS). Indeed, adsorption of these compounds resulted independent of water quality. In this study was also investigated the applicability of UV254 and fluorescing PARAFAC components to act as surrogates in predicting EOCs removal by GAC in different water matrices. Empirical linear correlation for the investigated EOCs were determined with UV254 and fluorescing components in all water qualities. However, fluorescence measurements resulted more sensitive than UV254 to predict EOC breakthrough during GAC adsorption. When the data from all water qualities was combined, good correlations between the microbial humic-like PARAFAC component and EOC removals were still observed and they resulted independent of water quality if considering only real water matrices (wastewater and surface water). On the contrary, correlations between EOC removals and UV254 removals were independent of water quality when combining data of surface waters and synthetic water, but a different correlation model was needed to predict EOCs breakthrough in wastewater.
Copyright © 2018. Published by Elsevier Ltd.

Entities:  

Keywords:  Fluorescence EEM; Granular activated carbon; PARAFAC; PFAS; Pharmaceutical and personal care products; Real-time monitoring

Mesh:

Substances:

Year:  2018        PMID: 30205338     DOI: 10.1016/j.watres.2018.09.018

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Impact of algal organic matter on the performance, cyanotoxin removal, and biofilms of biologically-active filtration systems.

Authors:  Youchul Jeon; Lei Li; Jose Calvillo; Hodon Ryu; Jorge W Santo Domingo; Onekyun Choi; Jess Brown; Youngwoo Seo
Journal:  Water Res       Date:  2020-07-01       Impact factor: 11.236

2.  Biochar Water Treatment for Control of Organic Micropollutants with UVA Surrogate Monitoring.

Authors:  Joshua Kearns; Eric Dickenson; Myat Thandar Aung; Sarangi Madhavi Joseph; Scott R Summers; Detlef Knappe
Journal:  Environ Eng Sci       Date:  2021-05-24       Impact factor: 1.907

3.  Data on the effects of filters, storage conditions, and chlorination in fluorescence and absorbance wastewater measurements.

Authors:  Massimiliano Sgroi; Erica Gagliano; Federico G A Vagliasindi; Paolo Roccaro
Journal:  Data Brief       Date:  2020-01-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.