Literature DB >> 30198806

Validation of the Fitbit Zip and Fitbit Flex with pregnant women in free-living conditions.

A St-Laurent1, M M Mony1, M È Mathieu2,3, S M Ruchat1.   

Abstract

Physical activity (PA) is a part of a healthy pregnancy. To date, no consumer-based activity monitors have been validated with this population. The aim of this study was to validate the Fitbit Zip and Fitbit Flex monitors in free-living conditions with pregnant women using the ActiGraph GT3X as the ?gold standard?. We compared the accuracy of the Fitbit Zip and Fitbit Flex devices in measuring steps, sedentary time and time spent in different activity intensities. Sixteen women in their third trimester of pregnancy wore the ActiGraph GT3X (hip) plus one Fibit Zip (hip) and one Fitbit Flex (wrist) during seven consecutive days. The validity of Fitbit Zip and Fitbit Flex is good, depending on measured parameters. Fitbit Zip is accurate to measure steps whereas Fitbit Flex is precise for MVPA. When choosing between Fitbit Zip and Fitbit Flex monitors, pregnant women should take into account their preferred PA and the parameters they want to measure..

Entities:  

Keywords:  ActiGraph; Fitbit; Validation; physical activity; pregnancy

Mesh:

Year:  2018        PMID: 30198806     DOI: 10.1080/03091902.2018.1472822

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  6 in total

1.  Healthy for My Baby Research Protocol- a Randomized Controlled Trial Assessing a Preconception Intervention to Improve the Lifestyle of Overweight Women and Their Partners.

Authors:  Isabelle Hardy; Amanda Lloyd; Anne-Sophie Morisset; Felix Camirand Lemyre; Jean-Patrice Baillargeon; William D Fraser
Journal:  Front Public Health       Date:  2021-08-03

2.  I-ACT: Integrated study on effect of Activity on ComplicaTions in pregnancy: study protocol of a multiethnic prospective cohort study.

Authors:  Meijin Cai; Kok Hian Tan; Seng Bin Ang
Journal:  BMJ Open       Date:  2019-04-03       Impact factor: 2.692

Review 3.  Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review.

Authors:  Marco Giurgiu; Irina Timm; Marlissa Becker; Steffen Schmidt; Kathrin Wunsch; Rebecca Nissen; Denis Davidovski; Johannes B J Bussmann; Claudio R Nigg; Markus Reichert; Ulrich W Ebner-Priemer; Alexander Woll; Birte von Haaren-Mack
Journal:  JMIR Mhealth Uhealth       Date:  2022-06-09       Impact factor: 4.947

4.  Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review.

Authors:  Daniel Fuller; Emily Colwell; Jonathan Low; Kassia Orychock; Melissa Ann Tobin; Bo Simango; Richard Buote; Desiree Van Heerden; Hui Luan; Kimberley Cullen; Logan Slade; Nathan G A Taylor
Journal:  JMIR Mhealth Uhealth       Date:  2020-09-08       Impact factor: 4.773

5.  Inter-Device Agreement between Fitbit Flex 1 and 2 for Assessing Sedentary Behavior and Physical Activity.

Authors:  Sunku Kwon; Ryan D Burns; Youngwon Kim; Yang Bai; Wonwoo Byun
Journal:  Int J Environ Res Public Health       Date:  2021-03-08       Impact factor: 3.390

Review 6.  Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature.

Authors:  Federico Germini; Noella Noronha; Victoria Borg Debono; Binu Abraham Philip; Drashti Pete; Tamara Navarro; Arun Keepanasseril; Sameer Parpia; Kerstin de Wit; Alfonso Iorio
Journal:  J Med Internet Res       Date:  2022-01-21       Impact factor: 5.428

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.