Literature DB >> 30198329

Stability and visual outcomes yielded by three intraocular trifocal lenses with same optical zone design but differing material or toricity.

Francisco Poyales1, Nuria Garzón1, Daniel Pizarro2, Santiago Cobreces2, Adolfo Hernández1,2.   

Abstract

PURPOSE: To compare rotational stability, centration and visual outcomes provided by three trifocal lens models that have the same optical zone design but different material, composition, and/or toricity.
METHODS: The study included 78 patients with symmetric bilateral intraocular lens implantation. The lenses under evaluation were trifocal intraocular lenses made of hydrophilic acrylic material: a spherical lens 26% hydrophilic acrylic (POD FineVision), a similar lens but having a toric design (POD Toric FineVision), and a trifocal lens 25% hydrophilic acrylic material (FineVision/MicroF). Moreover, the lenses share the same optical zone design. The lenses' rotational stability and centration were measured by means of the PIOLET software, which relies on recording and image processing techniques to determine lens rotation and centration based on slit-lamp images. We also assessed patients' visual quality by means of 25, 40, and 80 cm VA tests.
RESULTS: The best centration results were achieved with the POD Toric FineVision model, although the differences were not statistically significant. As for lens rotation, it was below 5° in all cases under study. Regarding VA, all subjects attained at least 0.3 logMAR for far distance uncorrected VA, at 80 cm VA was about 0.2 logMAR, at 40 cm it was above 0.15 logMAR, and at 25 cm it was about 0.3 logMAR for both lens types.
CONCLUSION: All three intraocular lens models yield excellent visual results at far, near as well as intermediate distances. The POD FineVision and POD Toric FineVision models, with double C-loop design, yielded the best results centration-wise and rotation-wise. Differences had no clinical relevance.

Entities:  

Keywords:  Trifocal; astigmatism; cataract; intraocular lens; rotation

Mesh:

Year:  2018        PMID: 30198329     DOI: 10.1177/1120672118795065

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  3 in total

1.  Comparison of Visual Performance and Patient Satisfaction Outcomes with Two Trifocal IOLs with Similar Optical Design but Different Materials.

Authors:  Francisco Poyales; Ricardo Pérez; Israel López-Brea; Ying Zhou; Laura Rico; Nuria Garzón
Journal:  Clin Ophthalmol       Date:  2020-10-13

2.  First Results after Implantation of Hydrophilic and Hydrophobic Trifocal Intraocular Lenses: Visual and Optical Performance.

Authors:  Francisco Poyales; Ricardo Pérez; Israel López-Brea; Ying Zhou; Nuria Garzón
Journal:  J Ophthalmol       Date:  2021-12-18       Impact factor: 1.909

3.  Deviation from the planned axis of three toric intraocular lenses.

Authors:  Shira Sheen-Ophir; Olga Reitblat; Adi Levy; Ehud I Assia; Guy Kleinmann
Journal:  Sci Rep       Date:  2022-08-12       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.