Mirjam Kummer1, Nela Šestáková1, Regula Theurillat1, Uyen Huynh-Do2, Andrea Endimiani3, Parham Sendi3,4,5, Wolfgang Thormann1.
Abstract
Cefepime monitoring in urine by micellar electrokinetic capillary chromatography with UV detection and liquid chromatography coupled to mass spectrometry via electrospray ionization is described. For micellar electrokinetic capillary chromatography, sample preparation comprised urine dilution and dodecyl-sulfate protein precipitation at pH 4.5, whereas diluted urines were analyzed in the other assay. Both approaches provided suitable conditions for cefepime analysis in urines of healthy volunteers that were spiked with cefepime. Cefepime monitoring by micellar electrokinetic capillary chromatography in samples from patients taking multiple drugs were prone to interferences, whereas liquid chromatography coupled to mass spectrometry provided clean chromatograms and thus selective detection of cefepime in all samples. The latter assay was used to measure urinary cefepime in a prospective pilot study and to assess cefepime stability in urines at 25, 4, -20 and -70°C. The data suggest that urinary cefepime is stable for at least 72 h at all tested temperatures.Entities:
Keywords: capillary electrophoresis; cefepime; micellar electrokinetic capillary chromatography; therapeutic drug monitoring
Year: 2018 PMID: 30198147 DOI: 10.1002/jssc.201800763