Literature DB >> 30196479

Dose prescription point in forward intensity-modulated radiotherapy of breast and head/neck cancers.

Farzaneh Allaveisi1,2, Nasrin Amini3, Sohrab Sakineh Pour3.   

Abstract

In the forward intensity-modulated radiotherapy (FIMRT) technique of treatment planning, the isocenter cannot fulfill the requirements of the International Commission on Radiation Units and Measurements (ICRU) reference point. This study aimed to propose dose prescription points to be used in breast and head/neck cancer patients treated using the FIMRT technique. Two-hundred patients with head/neck (n = 100) and breast (n = 100) cancers were selected. Treatment plans involved using the FIMRT technique. The suggested reference points (SRPs) for dose prescription were placed at selected locations in the lateral neck site and the tangential site in breast and head/neck cancer patients, respectively. Next, doses at the SRPs (DSRPs) were compared to the planning treatment volume (PTV)-equivalent uniform dose (EUD) and mean dose in the PTV (Dmean) extracted from dose-volume histograms. The differences between DSRPs and Dmean for the PTVs were less than 2% in 78 cases and less than 1% in 28 cases. The DSRPs were comparable with the EUD in both types of PTVs; moreover, paired t test analyses indicated that the SRP doses and PTV EUD were statistically similar (p > 0.05). In 116 cases, the discrepancy between DSRP and EUD was less than 2% and less than 1% in 74 cases. The SRPs satisfy the ICRU requirement that the reference point dose should be clinically relevant and representative of the dose throughout the PTV. A consensus on the definition of the reference point is expected to lead to accurate inter-comparison between results from different treatment centers, facilitating the optimization of treatment procedures.

Entities:  

Keywords:  D mean; Dose–volume histogram; Equivalent uniform dose; Forward intensity-modulated radiotherapy; ICRU reference point; Multi leaf collimator; Prescription dose

Mesh:

Year:  2018        PMID: 30196479     DOI: 10.1007/s12194-018-0475-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  22 in total

1.  Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation.

Authors:  Cem Onal; Aydan Sonmez; Gungor Arslan; Ezgi Oymak; Ayse Kotek; Esma Efe; Serhat Sonmez; Yemliha Dolek
Journal:  Jpn J Radiol       Date:  2011-12-21       Impact factor: 2.374

2.  Re: Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems.

Authors:  James M Galvin; Ying Xiao; Walter J Curran
Journal:  J Natl Cancer Inst       Date:  2008-08-26       Impact factor: 13.506

3.  Comparison between the four-field box and field-in-field techniques for conformal radiotherapy of the esophagus using dose-volume histograms and normal tissue complication probabilities.

Authors:  Farzaneh Allaveisi; Amir Nami Moghadam
Journal:  Jpn J Radiol       Date:  2017-04-18       Impact factor: 2.374

4.  Precision in reporting the dose given in a course of radiotherapy.

Authors:  S Dische; M I Saunders; C Williams; A Hopkins; E Aird
Journal:  Radiother Oncol       Date:  1993-12       Impact factor: 6.280

5.  Forward-planned, multiple-segment, tangential fields with concomitant boost in the treatment of breast cancer.

Authors:  Charles Mayo; Y C Lo; Thomas J Fitzgerald; Marcia Urie
Journal:  Med Dosim       Date:  2004       Impact factor: 1.482

6.  Intensity modulation to improve dose uniformity with tangential breast radiotherapy: initial clinical experience.

Authors:  L L Kestin; M B Sharpe; R C Frazier; F A Vicini; D Yan; R C Matter; A A Martinez; J W Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-12-01       Impact factor: 7.038

7.  Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.

Authors:  Panayiotis Mavroidis; Brigida Costa Ferreira; Chengyu Shi; Bengt K Lind; Nikos Papanikolaou
Journal:  Phys Med Biol       Date:  2007-05-31       Impact factor: 3.609

8.  Optimization of tumour control probability for heterogeneous tumours in fractionated radiotherapy treatment protocols.

Authors:  D Levin-Plotnik; R J Hamilton
Journal:  Phys Med Biol       Date:  2004-02-07       Impact factor: 3.609

9.  Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems.

Authors:  Indra J Das; Chee-Wai Cheng; Kashmiri L Chopra; Raj K Mitra; Shiv P Srivastava; Eli Glatstein
Journal:  J Natl Cancer Inst       Date:  2008-02-26       Impact factor: 13.506

10.  Evaluation of the field-in-field technique with lung blocks for breast tangential radiotherapy.

Authors:  Hidekazu Tanaka; Shinya Hayashi; Yuichi Kajiura; Masashi Kitahara; Katsuya Matsuyama; Masayuki Kanematsu; Hiroaki Hoshi
Journal:  Nagoya J Med Sci       Date:  2015-08       Impact factor: 1.131

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.