Literature DB >> 30195119

Development of novel portable and reusable fiber optical chemiluminescent biosensor and its application for sensitive detection of microcystin-LR.

Rong Yang1, Dan Song1, Shunyan Fang1, Yanping Liu1, Xiaohong Zhou2, Feng Long3, Anna Zhu4.   

Abstract

A novel portable fiber optical chemiluminescent biosensor (FOCB) system was successfully constructed using fiber optic bio-probe as biorecognition element as well as transducer and a Si-based photodiode detector (PD-3000). The compact design of FOCB with free magnetic beads and photomultiplier allows it to be portable and suitable for on-site and automatic detection of targets, as well as to be cost-effective and small sample volume (only 40.0 µL). The sensitivity of 5 fW could be obtained for the FOCB due to the high performance of PD-3000 and no background light signal. Next, the FOCB was applied for the CL-based detection of microcystin-LR (MC-LR) in water using hapten-carrier protein conjugates modified fiber optic bio-probe as biorecognition element. Based on indirect competitive sandwich-like CL immunoassay principle, the highly sensitive detection of MC-LR was achieved using FOCB system. Under optimal conditions, the limit of detection for MC-LR is 0.03 µg/L, which is comparable with that of most reported MC-LR immunoassay methods. The robustness of the hapten-carrier protein-modified biosensor surface allowed multiple MC-LR immunoassays without any significant loss of performance, which ensured accurate and cost-effective detection results. The proposed strategy demonstrated good recovery, precision, and accuracy through the evaluation of the spiked water samples. The FOCB system can be readily extended toward the on-site real-time sensitive detection of other targets in the field of environment, food, and medical diagnosis.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chemiluminescence biosensor; Fiber optical bio-probe; Immunoassay; Microcystin-LR; Photodiode detector

Mesh:

Substances:

Year:  2018        PMID: 30195119     DOI: 10.1016/j.bios.2018.08.062

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Reusable chemiluminescent fiber optic aptasensor for the determination of 17β-estradiol in water samples.

Authors:  Rong Yang; Jiayao Liu; Dan Song; Anna Zhu; Wenjuan Xu; Hongliang Wang; Feng Long
Journal:  Mikrochim Acta       Date:  2019-10-27       Impact factor: 5.833

Review 2.  Cyanotoxins and Food Contamination in Developing Countries: Review of Their Types, Toxicity, Analysis, Occurrence and Mitigation Strategies.

Authors:  Mohamed F Abdallah; Wannes H R Van Hassel; Mirjana Andjelkovic; Annick Wilmotte; Andreja Rajkovic
Journal:  Toxins (Basel)       Date:  2021-11-06       Impact factor: 4.546

3.  Synthesis of magnetic core-shell Fe3O4@PDA@Cu-MOFs composites for enrichment of microcystin-LR by MALDI-TOF MS analysis.

Authors:  Zhijian Li; Congcong Gong; Panpan Huo; Chunhui Deng; Shouzhi Pu
Journal:  RSC Adv       Date:  2020-08-05       Impact factor: 4.036

Review 4.  A Mini-Review on Detection Methods of Microcystins.

Authors:  Isaac Yaw Massey; Pian Wu; Jia Wei; Jiayou Luo; Ping Ding; Haiyan Wei; Fei Yang
Journal:  Toxins (Basel)       Date:  2020-10-04       Impact factor: 4.546

Review 5.  Immunosensing Based on Optical Fiber Technology: Recent Advances.

Authors:  Maria Simone Soares; Miguel Vidal; Nuno F Santos; Florinda M Costa; Carlos Marques; Sónia O Pereira; Cátia Leitão
Journal:  Biosensors (Basel)       Date:  2021-08-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.