Literature DB >> 30195116

Comparative study of the wear of the pair human teeth/Vita Enamic® vs commonly used dental ceramics through chewing simulation.

F Santos1, A Branco2, M Polido3, A P Serro4, C G Figueiredo-Pina5.   

Abstract

Ceramic based prosthetic materials have been used in dental restorations due to their excellent aesthetic and biocompatibility. However, due to concerns related to their mechanical properties and abrasive action against natural teeth, a proper selection of these materials is crucial to preserve the occlusal interactions and prevent abnormal dental wear. The aim of this work is to compare the wear performance of Vita Enamic®, a polymer infiltrated ceramic (PIC), with that of other three commercial ceramic based dental materials - Zirconia, Leucite and Zirconia Veneered - when tested against natural teeth. The crystalline structure, wettability, topography and hardness of the prosthetic materials were characterized before wear testing. Chewing simulator experiments (360,000 cycles, load 49 N) against dental human cusps were carried out using artificial saliva as lubricant. The wear of both teeth and prosthetic materials was quantified and the involved wear mechanisms were analyzed by scanning electron microscopy. The results showed that Zirconia presented the most suitable tribological behavior, since it led to the lowest wear on both occlusal surfaces. The prosthetic material presenting the highest wear was Vita Enamic®. Regarding the cusps' wear, the highest values were found for both Leucite and Zirconia Veneered. Polishing wear was the main wear mechanism in Zirconia system (prosthetic material and opposing enamel), while in the remaining ones was fragile fracture associated with abrasive wear. No direct relation could be established between wettability, initial roughness and hardness of the prosthetic materials and the wear of the tribological systems. Contrarily, microstructure and toughness revealed to be critical parameters.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Chewing simulation; Leucite; Vita Enamic®; Wear; Zirconia; Zirconia veneered

Mesh:

Substances:

Year:  2018        PMID: 30195116     DOI: 10.1016/j.jmbbm.2018.08.029

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  2 in total

1.  Wear of ceramic-based dental materials.

Authors:  Oscar Borrero-Lopez; Fernando Guiberteau; Yu Zhang; Brian R Lawn
Journal:  J Mech Behav Biomed Mater       Date:  2019-01-12

2.  Evaluating the effect of repeated use of milling burs on surface roughness and adaptation of digitally fabricated ceramic veneers.

Authors:  Leila Payaminia; Naeime Moslemian; Shima Younespour; Soudabeh Koulivand; Marzieh Alikhasi
Journal:  Heliyon       Date:  2021-04-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.