Novel Surgical Approach to Segmental Bone Transport Using a Magnetic Intramedullary Limb Lengthening System.

Gonzalo Barinaga1, Austin M Beason, Matthew P Gardner.   

Abstract

Posttraumatic bone defects (BDs) remain a difficult complication for orthopaedic surgeons. Surgical goals in these reconstructive cases are to create stable limb fixation, maintain limb length, and provide adequate soft-tissue coverage. Historically, surgical approaches in these cases have required the use of an external fixator, which is associated with several postoperative complications. A plate-assisted bone segment transport (PABST) technique using a magnetic limb lengthening system eliminates the need for an external fixator and is effective for these reconstructive cases. A 51-year-old male patient presented as a category I trauma after a motorcycle collision. Osseous injury was defined as Gustilo-Anderson type IIIB distal tibia and fibula fracture (AO 42-C2). After fixation failure, the PABST technique was performed using a magnetic intramedullary limb lengthening system. Radiographic union was achieved 18 months postoperatively. This innovative surgical technique is effective in treating posttraumatic BDs without the need for limb shortening or the use of an external fixator. PABST has the potential to decrease postoperative complications in BD reconstructive cases using all-internal technology designed for limb lengthening. PABST, in this instance, uses a magnetic intramedullary nail that is controlled with a hand-held external remote to allow for precise, adjustable, and bidirectional bone segment transport.

Entities:  

Mesh:

Year:  2018        PMID: 30192254      PMCID: PMC6221376          DOI: 10.5435/JAAOS-D-17-00487

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


Long bone defects (BDs) usually follow high-energy trauma and are often associated with notable soft-tissue injury. Historically, the reconstruction of posttraumatic BD has relied on a number of surgical techniques including conventional and vascularized bone grafting, induced-membrane techniques, and several variations of bone transport.[123] These variations of bone transport were developed on the principles of distraction osteogenesis pioneered by Ilizarov and refined by Cattaneo et al and Catagni et al.[456] Since its inception, the Ilizarov method of bone transport has become common practice in reconstructive surgery for limb lengthening and management of BD. However, despite the physiologic nature of this method of bone transport, it involves the use of an external fixation device, which is associated with pin tract infections and decreased range of motion secondary to joint contractures.[1,789] Recent advances in technology have allowed for less invasive approaches. To eliminate the need for external fixation devices, several intramedullary (IM) nail lengthening systems have been developed. However, issues have been encountered with these devices related to weakness or mechanical instability of the IM nail, difficulty controlling rate of lengthening, pain with distraction, or deep bone infections.[89101112] Other described techniques for managing long BDs include lengthening over a nail, lengthening over a plate, definitive external fixation, conventional and vascularized bone grafting, and the Masquelet technique.[123,1011121314] Recently, the PRECICE 2 IM Limb Lengthening System (NuVasive), which relies on a noninvasive magnetic interaction between the IM nail and an external, portable, hand-held remote controller, was designed to allow for accurate lengthening of the tibia or femur.[15] The PRECICE 2 IM nail is available in four predistraction lengths: 195, 215, 230, and 245 mm. The 245 mm nail has a telescoping rod that allows for 80 mm of lengthening; the remaining nails have a telescoping rod that allows for 50 mm of lengthening. In contrast to previous approaches using motorized IM nails and skeletal kinetic distractors,[16,17] this system may prove to be a more precise distraction system and is capable of bidirectional control, which allows for distraction and also compression of the bone regenerate (ie, the accordion technique).[4,181920] However, to the knowledge of the authors, there has been no documented use of the PRECICE 2 IM Limb Lengthening System to correct a BD via segmental bone transport without shortening or concurrent use of an external fixation device. This case report is an account of a novel, plate-assisted bone segment transport (PABST) technique using the only IM limb lengthening system currently approved for use in the United States.

Case Report

The patient is a 51-year-old man with no notable medical history who was admitted as a category I trauma after a motorcycle versus car collision. The patient's injuries included a Gustilo-Anderson type IIIB distal tibia and fibula fracture (AO 42-C2) with intact neurovascular examination (Figure 1). Soft-tissue injury included a posteromedial wound at the distal third of the tibia measuring approximately 14.5 × 10 cm with exposed bone. Many surgical interventions were needed to achieve soft-tissue coverage, and a Synthes IM nail was placed during the course of management to provide skeletal stability, maintain length, and allow for unobstructed flap placement. At the patient's request for no further surgery, he was allowed to weight bear as tolerated and gradually return to activities, but he was informed that the nail would likely fail, and if this were to happen, some type of bone graft or transport would be required in the future. Ultimately, there was minimal callus formation, and failure of distal tibia fixation occurred 2 years after the original injury. The defect was estimated to be 3.0 cm after removal of hardware (Figure 2, A and B). Surgical options were discussed, and PABST was chosen.
Figure 1

AP (A) and lateral (B) radiographs at initial injury.

Figure 2

A, AP radiograph showing nail fixation failure. B, Intraoperative fluoroscopic image showing residual tibial defect after fibula fixation.

AP (A) and lateral (B) radiographs at initial injury. A, AP radiograph showing nail fixation failure. B, Intraoperative fluoroscopic image showing residual tibial defect after fibula fixation. One week after fixation failure, the patient presented for removal of his failed IM nail, débridement of his nonunion, open reduction and internal fixation of his tibia, and fibula and placement of the PRECICE 2 IM Limb Lengthening System (Figure 3).
Figure 3

AP (A) and lateral (B) radiographs of the plate-assisted bone segment transport construct with the PRECICE 2 IM nail in place.

AP (A) and lateral (B) radiographs of the plate-assisted bone segment transport construct with the PRECICE 2 IM nail in place.

Description of the Plate-assisted Bone Segment Transport Technique

The proximal portion of the nail was explanted without complications. An anterior incision was made over the tibial nonunion site medial to the flap, and dissection was continued down to the fracture site. The distal interlock bolts were removed, and the distal nail was explanted. An osteotomy of the distal tibial nonunion was then performed using an oscillating saw on low speed with continuous irrigation and frequent breaks to minimize thermal necrosis. The distal osteotomy sites (ie, the docking surfaces) should be flat and parallel with the ankle joint to improve surface area contact on docking and to help with proper alignment. Callus over the fibula was then carefully débrided with a rongeur. The fibular ends were then débrided to provide a good compressible construct. Alignment of the fibula helped establish the length, alignment, and rotation for the construct. A Synthes 10-hole limited-contact dynamic compression plate was applied in compression with two cortical and two locking screws at each end of the fracture site. After débridement and reduction of the fibula, the residual tibial defect was measured at 2.5 cm (Figure 2, B). Next, a medial Synthes distal tibia plate was placed across the fracture, sliding this proximal in a subcutaneous fashion to maintain soft-tissue integrity. The purpose of the plate was to maintain limb alignment during transport. A Synthes 16-hole variable-angle limited contact plate was the longest plate available to span the defect. The plate was secured distally with a combination of cortical and locking screws but was not yet fixed proximally to allow for the proximal corticotomy. With the fibula fixed and residual tibial defect established, nail parameters were then determined. The authors planned to place the distal interlock as close to the defect as possible to reduce the potential of transport segment drift. Therefore, a 245-mm nail with an 80-mm telescoping rod was selected to place the distal interlock as close to the defect as possible without sacrificing lengthening reserve. Nail diameter was chosen to achieve a good IM fit and reduce friction for the transport segment. With an infrapatellar approach, the tibial canal was reamed up to 10.5 mm, and an 8.5-mm-diameter nail was selected. A diaphyseal corticotomy was then performed, as described by De Bastiani et al,[18] using a 3.5-mm drill bit and finishing with an osteotome to prevent thermal injury. This procedure was performed 8 cm proximal to the defect site to allow for placement of four tibia plate proximal locking screws in the stationary piece. The nail was then placed in the canal and advanced distally past the corticotomy site, and a proximal interlock bolt was placed. The PRECICE 2 IM nail has three distal locking options: one AP and two medial-lateral (ML). The plan for the medial plate precluded the ML screws. Rotating the nail was considered; however, we chose not to place the ML screws because of the potential for contact between the screws and the medial plate during transport and the possibility of creating a proximal deformity. Therefore, a single AP distal interlocking bolt was placed to engage the transport segment. With distal locking screws already in place, the medial tibia plate was secured proximally with four bicortical locking screws that were placed anterior to the nail. To assess completion of the corticotomy, the nail was lengthened intraoperatively, and the transport segment was confirmed to move by comparing pre- and post-distraction fluoroscopic images.

Patient Progress

The patient was given instructions to be non–weight bearing on his surgical leg after surgery. His surgical wounds healed uneventfully. Lengthening began on postoperative day (POD) 7 and proceeded at a rate of 0.75 mm per day for 32 days (2.4 cm). The regenerate appeared underdeveloped, and on POD 39, the accordion technique as described by Makhdom[19] was performed by placing the magnet in the reverse direction at a rate of 0.5 mm per day for 40 days (2.0 cm). Once that was done, distraction was resumed at a rate of 0.5 mm per day for 40 days (2.0 cm). On POD 120, the docking site was then prepared by débridement with a curet and rongeur without complications. The final rate of distraction was slowed to 0.25 mm per day to maximize regenerate development and was continued until POD 128 when the distal interlocking bolt was seen to have a bend in it. The patient was permitted to return to weight-bearing activities with physical therapy on POD 156 when the regenerate appeared mature. Bone segment docking was noted radiographically on POD 128; however, 6 months later, the docking site showed resorption, indicating a nonunion. The regenerate was mature, and it was determined that compression with the PRECICE 2 nail would not work at this point. Ten months after placement, the PRECICE 2 nail was removed along with the medial plate, and a Synthes IM nail was placed along with iliac crest autograft to augment docking site consolidation. The patient showed increased callus formation at every visit following this procedure up until radiographic union. The consolidation index was 56.9 (d/cm) as assessed on plain radiographs, and radiographic union of the docking site occurred at 18 months after PRECICE 2 IM nail placement (Figure 4).
Figure 4

Radiographs showing stages of healing at 3 months (A), 8 months (B), and 18 months (C), as seen on AP radiographs.

Radiographs showing stages of healing at 3 months (A), 8 months (B), and 18 months (C), as seen on AP radiographs.

Discussion

The BD described in this report was noted initially to be 4.2 cm, which if managed according to the criteria outlined by Rigal et al[1] could have been initially shortened and then lengthened by distraction osteogenesis with a distant corticotomy site. However, in this case, the length and alignment were maintained by plate fixation, and transport was performed using the PRECICE 2 IM Limb Lengthening System. This technique has several advantages: (1) it reduces the risk of joint stiffness and muscle contracture associated with an initial shortening and secondary lengthening;[1,7,9] (2) it eliminates the need for an external fixation device, which is uncomfortable to patients and associated with several postoperative surgical complications; and (3) the magnetic device removes the need for a subcutaneous receiver antenna, therefore potentially removing a known source of failure.[21,22] The PRECICE 2 magnetic IM nail allows for precision distraction and bidirectional control, which may allow for better control of the transport segment and a more successful bone regenerate outcome. The authors recognize that the PABST technique will continue to be refined but feel that the technique offers a feasible and effective solution to a complex posttraumatic condition for surgeons confronted with challenging BDs. The PABST technique was successful in treating the segmental BD in this case. However, complications and areas for improvement have been identified. Poor growth in the regenerate was noted early in treatment, and one potential contributor was the diaphyseal location of the corticotomy. With this technique, the corticotomy site is dependent on the length of the plate. With the need to maintain the stationary and docking segments in proper alignment with the plate, the corticotomy site must be more distal than an ideal metaphyseal location. Another reason for slow regenerate development could have been that the transport rate was too fast in the beginning (0.25 mm 3 times daily), outrunning the regenerate, resulting in the need for the accordion technique. Ultimately, the regenerate did consolidate but took longer than anticipated. The second recognized complication was in achieving union at the docking site, and several issues may have contributed to this difficulty. In the initial procedure, an oscillating saw was used to osteotomize the nonunion site. Despite great care for bone biology and soft tissues, using an oscillating saw likely caused thermal necrosis at the docking site. Second, placing the nail as distal as possible may have reduced drift of the transport segment but may have also devitalized the endosteal blood supply needed for optimal health at the docking site. Third, the placement of only one screw in the transport segment may have also contributed to this issue. Although one screw was sufficient to support transport, more screws may have allowed for better compression once docked. Finally, in the procedure to prepare the docking site, iliac crest bone graft was not used. Autograft with iliac crest bone graft may have improved the chance of union at the docking site. The authors also feel that host factors may have played a notable role in the poor regenerate. Optimizing host biology by reviewing laboratory markers (vitamin D and calcium levels) and smoking cessation are important for success. Fortunately, this patient did comply with smoking cessation and dietary supplementation of vitamin D/calcium. Ultimately, PABST offers surgeons an alternative approach to managing BDs. The use of a magnetic nail with bidirectional control has the potential to reduce complications regarding nail escape and early consolidation. It also allowed for precise monitoring and control of the regenerate and eliminated the need for external fixation devices. Future cohort studies will be needed to determine the reliability, complications, and advantages of this technique.
  22 in total

1.  Functional results of lower extremity lengthening by motorized intramedullary nails.

Authors:  Hakan Dinçyürek; Mehmet Kocaoğlu; I Levent Eralp; F Erkal Bilen; Göksel Dikmen; Ilker Eren
Journal:  Acta Orthop Traumatol Turc       Date:  2012       Impact factor: 1.511

2.  Limb lengthening for post-traumatic shortening over a pre-implanted femoral locking plate.

Authors:  Dennis D Kosuge; Hannah Pugh; Anna Timms; Matthew Barry
Journal:  J Orthop Trauma       Date:  2013-03       Impact factor: 2.512

Review 3.  Clinical application of the tension-stress effect for limb lengthening.

Authors:  G A Ilizarov
Journal:  Clin Orthop Relat Res       Date:  1990-01       Impact factor: 4.176

4.  [Basic principles of transosseous compression and distraction osteosynthesis].

Authors:  G A Ilizarov
Journal:  Ortop Travmatol Protez       Date:  1971-11

5.  Bone transport techniques in posttraumatic bone defects.

Authors:  S Rigal; P Merloz; D Le Nen; H Mathevon; A-C Masquelet
Journal:  Orthop Traumatol Surg Res       Date:  2012-01-17       Impact factor: 2.256

6.  Complications of limb lengthening. A learning curve.

Authors:  M T Dahl; B Gulli; T Berg
Journal:  Clin Orthop Relat Res       Date:  1994-04       Impact factor: 4.176

7.  Ilizarov treatment of tibial nonunions with bone loss.

Authors:  D Paley; M A Catagni; F Argnani; A Villa; G B Benedetti; R Cattaneo
Journal:  Clin Orthop Relat Res       Date:  1989-04       Impact factor: 4.176

8.  Intramedullary leg lengthening with a motorized nail.

Authors:  Andreas H Krieg; Ulrich Lenze; Bernhard M Speth; Carol C Hasler
Journal:  Acta Orthop       Date:  2011-05-11       Impact factor: 3.717

9.  Comparison between lengthening over nail and conventional Ilizarov lengthening: a prospective randomized clinical study.

Authors:  Timour F El-Husseini; Nabil A M Ghaly; Mahmoud A Mahran; Mohamed Ahmed Al Kersh; Khaled M Emara
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-08-02

10.  The Accordion Maneuver: A Noninvasive Strategy for Absent or Delayed Callus Formation in Cases of Limb Lengthening.

Authors:  Asim M Makhdom; Adrian Sever Cartaleanu; Juan Sebastian Rendon; Isabelle Villemure; Reggie C Hamdy
Journal:  Adv Orthop       Date:  2015-10-19
View more
  10 in total

1.  Use of Tantalum Trabecular Metal Cones for Management of Nonunion of the Distal Femur with Segmental Bone Defects: Technique and Case Series.

Authors:  Alan W Reynolds; Patricia R Melvin; Eric J Yakish; Nicholas Sotereanos; Gregory T Altman; Jeffrey J Sewecke
Journal:  J Orthop Case Rep       Date:  2021-07

2.  All Internal Bone Transport: Use of a Lengthening Nail and Double Plating for Management of Femoral Bone Loss.

Authors:  Jonathan Wright; Peter Bates; Nima Heidari; Alexandros Vris
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 May-Aug

3.  The PRECICE magnetic IM compression nail for long bone nonunions: a preliminary report.

Authors:  Austin T Fragomen; David Wellman; S Robert Rozbruch
Journal:  Arch Orthop Trauma Surg       Date:  2019-06-19       Impact factor: 3.067

Review 4.  Bone transport with magnetic intramedullary nails in long bone defects.

Authors:  Selina Summers; Matija Krkovic
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-12-24

Review 5.  Lengthening Nails for Distraction Osteogenesis: A Review of Current Practice and Presentation of Extended Indications.

Authors:  Ahmed H Barakat; Junaid Sayani; Christopher O'Dowd-Booth; Enis Guryel
Journal:  Strategies Trauma Limb Reconstr       Date:  2020 Jan-Apr

6.  Managing bone loss in open fractures.

Authors:  Andrew Adamczyk; Bradley Meulenkamp; Geoffrey Wilken; Steven Papp
Journal:  OTA Int       Date:  2020-03-23

7.  Efficacy comparison of trifocal bone transport using unilateral external fixator for femoral and tibial bone defects caused by infection.

Authors:  Kai Liu; Yanshi Liu; Feiyu Cai; Chenchen Fan; Peng Ren; Aihemaitijiang Yusufu
Journal:  BMC Surg       Date:  2022-04-12       Impact factor: 2.102

Review 8.  Current Perspectives on the Management of Bone Fragments in Open Tibial Fractures: New Developments and Future Directions.

Authors:  Muhamed M Farhan-Alanie; Jayne Ward; Michael B Kelly; Khalid Al-Hourani
Journal:  Orthop Res Rev       Date:  2022-08-12

9.  Cambridge Protocol for Management of Segmental Bone Loss.

Authors:  Maria Tennyson; Ada Maria Krzak; Matija Krkovic; Ali Abdulkarim
Journal:  J Orthop Case Rep       Date:  2021

10.  Management of post-traumatic femoral defects with a monorail external fixator over an intramedullary nail.

Authors:  Victor Lu; James Zhang; Andrew Zhou; Matija Krkovic
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-08-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.