Literature DB >> 30190039

Editor's Choice - Mid-term Migration and Device Failure Following Endovascular Aneurysm Sealing with the Nellix Stent Graft System - a Single Centre Experience.

Seamus C Harrison1, Andrew J Winterbottom2, Patrick A Coughlin2, Paul D Hayes2, Jonathan R Boyle2.   

Abstract

OBJECTIVE: Endovascular aneurysm sealing (EVAS) with the Nellix stent graft system is a novel concept in the management of abdominal aortic aneurysm (AAA) that aims to reduce the prevalence of all endoleaks following endovascular repair. There are few data describing the longer-term durability of this approach. The aim was to report the longer-term outcomes following EVAS in a single centre.
METHODS: This is a retrospective review of all patients that underwent Nellix at Cambridge University Hospitals Foundation Trust. Factors that are described as device failure include secondary sac rupture, graft explantation, further surgical procedures for Type 1 endoleak, or major migration of the stent grafts with pressurisation of the aortic sac.
RESULTS: A total of 161 patients have been treated with Nellix. The indications included primary AAA (n = 115), ruptured AAA (n = 4), salvage of other aortic grafts (n = 18), primary iliac aneurysm (n = 6), and chimney EVAS (ChEVAS) for pararenal AAA (n = 18). In total there have been 42 graft failures in patients treated with EVAS for primary AAA. The 4 year freedom from graft failure was 42% in patients treated for primary AAA. Failures mostly occurred more than 2 years post-Nellix implant. There were eight secondary sac ruptures (incidence 2.4 per 100 person years) and there have been 14 graft explants.
CONCLUSIONS: Failure of aneurysm sealing following treatment with Nellix has been more common than anticipated and can cause aortic rupture. Post-operative surveillance of Nellix stent grafts is crucial to identify features of failure.
Copyright © 2018. Published by Elsevier B.V.

Entities:  

Keywords:  Abdominal aortic aneurysm; EVAS; Endoleak; Endovascular sealing; Graft failure; Nellix

Mesh:

Year:  2018        PMID: 30190039     DOI: 10.1016/j.ejvs.2018.06.031

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  5 in total

1.  Endovascular Aneurysm Sealing is Associated with Higher Medium-Term Survival than Traditional EVAR.

Authors:  Thomas F X O'Donnell; Jeffrey P Carpenter; John S Lane; Jose Trani; Sajjad Hussain; Christopher Healey; Mahmoud B Malas; Marc L Schermerhorn
Journal:  Ann Vasc Surg       Date:  2019-10-16       Impact factor: 1.466

2.  The use of an inner branch endograft for the treatment of failed chimney endovascular aortic repair.

Authors:  Avner Bar Dayan; Daniel Silverberg; Chen Speter; Moshe Halak
Journal:  J Vasc Surg Cases Innov Tech       Date:  2020-10-27

Review 3.  Evaluating quality in clinical care.

Authors:  Aminder A Singh; Jonathan R Boyle
Journal:  Surgery (Oxf)       Date:  2020-08-30

4.  Systematic Review on the Mid-Term Outcomes of Elective Endovascular Aneurysm Sealing in Comparison to Endovascular Aneurysm Repair.

Authors:  Aleksandra C Zoethout; Iris Hochstenbach; Maarten J van der Laan; Jean-Paul P M de Vries; Michel M P J Reijnen; Clark J Zeebregts
Journal:  J Endovasc Ther       Date:  2021-09-27       Impact factor: 3.089

5.  Late failure of a Nellix endoprosthesis treated with the t-Branch off-the-shelf multibranched stent graft.

Authors:  Antonio Lorido; Matteo Orrico; Mario Marino; Alessio Vona; Sonia Ronchey; Nicola Mangialardi
Journal:  J Vasc Surg Cases Innov Tech       Date:  2019-11-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.