Literature DB >> 30180573

Probing the Sensitivity of the Orbitrap Lumos Mass Spectrometer Using a Standard Reference Protein in a Complex Background.

Michaella J Levy1, Michael P Washburn1,2, Laurence Florens1.   

Abstract

The use of mass spectrometry as a tool to detect proteins of biological interest has become a cornerstone of proteomics. The popularity of mass spectrometry-based methods has increased along with instrument improvements in detection and speed. The Orbitrap Fusion Lumos mass spectrometer has recently been shown to have better fragmentation and detection than its predecessors. Here, we determined the sensitivity of the Lumos using the NIST monoclonal antibody reference material at various concentrations to detect its peptides in a background of S. cerevisiae whole cell lysate, which was kept at a constant concentration. The data collected by data-dependent acquisition showed that the spiked protein could be detected at 10 pg by an average of 4 peptides in 250 ng of whole cell lysate when the instrument was operated by detecting the peptide masses in the Orbitrap and the fragment masses in the ion trap (FTIT mode). In contrast, when the peptides and fragments were both detected in the Orbitrap on either the Lumos or Q-Exactive Plus (FTFT mode), the lowest concentration of NIST monoclonal antibody detected was 50 pg. The Lumos can detect a single protein at a level 2500 times lower than the whole cell background and the combination of detecting ions in the Orbitrap and ion trap can improve the identification of low abundance proteins. Furthermore, the total number of proteins identified from decreasing starting amounts of whole cell extracts was determined. The Lumos, when operated in FTIT mode, was able to identify twice as many proteins compared to the Q-Exactive+ at 5 ng of whole cell lysate. Similar numbers of proteins were identified on both platforms at higher concentrations of starting material. Therefore, the Lumos mass spectrometer is especially useful for detecting proteins of low abundance in complex backgrounds or samples that have limited starting material.

Entities:  

Keywords:  Orbitrap Lumos; Proteomics; data-dependent acquisition; limit of detection; mass spectrometry; sensitivity

Mesh:

Substances:

Year:  2018        PMID: 30180573      PMCID: PMC6836688          DOI: 10.1021/acs.jproteome.8b00269

Source DB:  PubMed          Journal:  J Proteome Res        ISSN: 1535-3893            Impact factor:   4.466


  20 in total

1.  An automated multidimensional protein identification technology for shotgun proteomics.

Authors:  D A Wolters; M P Washburn; J R Yates
Journal:  Anal Chem       Date:  2001-12-01       Impact factor: 6.986

Review 2.  Mass spectrometry-based proteomics.

Authors:  Ruedi Aebersold; Matthias Mann
Journal:  Nature       Date:  2003-03-13       Impact factor: 49.962

3.  Quantitative mass spectrometry-based multiplexing compares the abundance of 5000 S. cerevisiae proteins across 10 carbon sources.

Authors:  Joao A Paulo; Jeremy D O'Connell; Robert A Everley; Jonathon O'Brien; Micah A Gygi; Steven P Gygi
Journal:  J Proteomics       Date:  2016-07-16       Impact factor: 4.044

Review 4.  Orbitrap mass spectrometry: instrumentation, ion motion and applications.

Authors:  Richard H Perry; R Graham Cooks; Robert J Noll
Journal:  Mass Spectrom Rev       Date:  2008 Nov-Dec       Impact factor: 10.946

5.  Parallel Comparison of N-Linked Glycopeptide Enrichment Techniques Reveals Extensive Glycoproteomic Analysis of Plasma Enabled by SAX-ERLIC.

Authors:  Sarah M Totten; Christa L Feasley; Abel Bermudez; Sharon J Pitteri
Journal:  J Proteome Res       Date:  2017-02-15       Impact factor: 4.466

6.  Effect of dynamic exclusion duration on spectral count based quantitative proteomics.

Authors:  Ying Zhang; Zhihui Wen; Michael P Washburn; Laurence Florens
Journal:  Anal Chem       Date:  2009-08-01       Impact factor: 6.986

Review 7.  Evolution of Orbitrap Mass Spectrometry Instrumentation.

Authors:  Shannon Eliuk; Alexander Makarov
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2015       Impact factor: 10.745

8.  ProLuCID: An improved SEQUEST-like algorithm with enhanced sensitivity and specificity.

Authors:  T Xu; S K Park; J D Venable; J A Wohlschlegel; J K Diedrich; D Cociorva; B Lu; L Liao; J Hewel; X Han; C C L Wong; B Fonslow; C Delahunty; Y Gao; H Shah; J R Yates
Journal:  J Proteomics       Date:  2015-07-11       Impact factor: 4.044

9.  Large-scale analysis of the yeast proteome by multidimensional protein identification technology.

Authors:  M P Washburn; D Wolters; J R Yates
Journal:  Nat Biotechnol       Date:  2001-03       Impact factor: 54.908

10.  Subnanogram proteomics: impact of LC column selection, MS instrumentation and data analysis strategy on proteome coverage for trace samples.

Authors:  Ying Zhu; Rui Zhao; Paul D Piehowski; Ronald J Moore; Sujung Lim; Victoria J Orphan; Ljiljana Paša-Tolić; Wei-Jun Qian; Richard D Smith; Ryan T Kelly
Journal:  Int J Mass Spectrom       Date:  2017-09-01       Impact factor: 1.986

View more
  5 in total

1.  Evaluating Chromatographic Approaches for the Quantitative Analysis of a Human Proteome on Orbitrap-Based Mass Spectrometry Systems.

Authors:  Ying Zhang; Zhihui Wen; Michael P Washburn; Laurence Florens
Journal:  J Proteome Res       Date:  2019-03-27       Impact factor: 4.466

2.  Metabolism of PLTP, CETP, and LCAT on multiple HDL sizes using the Orbitrap Fusion Lumos.

Authors:  Sasha A Singh; Allison B Andraski; Hideyuki Higashi; Lang Ho Lee; Ashisha Ramsaroop; Frank M Sacks; Masanori Aikawa
Journal:  JCI Insight       Date:  2021-02-08

3.  mRNA display with library of even-distribution reveals cellular interactors of influenza virus NS1.

Authors:  Yushen Du; Judd F Hultquist; Quan Zhou; Anders Olson; Yenwen Tseng; Tian-Hao Zhang; Mengying Hong; Kejun Tang; Liubo Chen; Xiangzhi Meng; Michael J McGregor; Lei Dai; Danyang Gong; Laura Martin-Sancho; Sumit Chanda; Xinming Li; Steve Bensenger; Nevan J Krogan; Ren Sun
Journal:  Nat Commun       Date:  2020-05-15       Impact factor: 14.919

4.  NAP1-RELATED PROTEIN1 and 2 negatively regulate H2A.Z abundance in chromatin in Arabidopsis.

Authors:  Yafei Wang; Zhenhui Zhong; Yaxin Zhang; Linhao Xu; Suhua Feng; Shima Rayatpisheh; James A Wohlschlegel; Zonghua Wang; Steven E Jacobsen; Israel Ausin
Journal:  Nat Commun       Date:  2020-06-08       Impact factor: 14.919

5.  Affinity-Bead Assisted Mass Spectrometry (Affi-BAMS): A Multiplexed Microarray Platform for Targeted Proteomics.

Authors:  Ghaith M Hamza; Vladislav B Bergo; Sergey Mamaev; Don M Wojchowski; Paul Toran; Camilla R Worsfold; M Paola Castaldi; Jeffrey C Silva
Journal:  Int J Mol Sci       Date:  2020-03-16       Impact factor: 5.923

  5 in total