Literature DB >> 30178639

An anti-passivation ink for the preparation of electrodes for use in electrochemical immunoassays.

Qi-Qi Zheng1,2, Yuan-Chao Lu1,2, Zun-Zhong Ye1,2, Jian-Feng Ping1,2, Jian Wu1,2, Yi-Bin Ying1,2,3.   

Abstract

p-Nitrophenylphosphate (PNPP) is usually employed as the substrate for enzyme-linked immunosorbent assays. p-Nitrophenol (PNP), the product of PNPP, with the catalyst alkaline phosphatase (ALP), will passivate an electrode, which limits applications in electrochemical analysis. A novel anti-passivation ink used in the preparation of a graphene/ionic liquid/chitosan composited (rGO/IL/Chi) electrode is proposed to solve the problem. The anti-passivation electrode was fabricated by directly writing the graphene-ionic liquid-chitosan composite on a single-side conductive gold strip. A glassy carbon electrode, a screen-printed electrode, and a graphene-chitosan composite-modified screen-printed electrode were investigated for comparison. Scanning electron microscopy was used to characterize the surface structure of the four different electrodes and cyclic voltammetry was carried out to compare their performance. The results showed that the rGO/IL/Chi electrode had the best performance according to its low peak potential and large peak current. Amperometric responses of the different electrodes to PNP proved that only the rGO/IL/Chi electrode was capable of anti-passivation. The detection of cardiac troponin I was used as a test example for electrochemical immunoassay. Differential pulse voltammetry was performed to detect cardiac troponin I and obtain a calibration curve. The limit of detection was 0.05 ng/ml.

Entities:  

Keywords:  Electrochemical immunoassay; Electrode ink; Anti-passivation; Ionic liquid; p-Nitrophenol

Mesh:

Substances:

Year:  2018        PMID: 30178639      PMCID: PMC6137421          DOI: 10.1631/jzus.B1700510

Source DB:  PubMed          Journal:  J Zhejiang Univ Sci B        ISSN: 1673-1581            Impact factor:   3.066


  15 in total

1.  Application of electrochemically reduced graphene oxide on screen-printed ion-selective electrode.

Authors:  Jianfeng Ping; Yixian Wang; Yibin Ying; Jian Wu
Journal:  Anal Chem       Date:  2012-03-12       Impact factor: 6.986

2.  A paper-based nanomodified electrochemical biosensor for ethanol detection in beers.

Authors:  Stefano Cinti; Mattia Basso; Danila Moscone; Fabiana Arduini
Journal:  Anal Chim Acta       Date:  2017-01-23       Impact factor: 6.558

3.  A three-dimensional interpenetrating electrode of reduced graphene oxide for selective detection of dopamine.

Authors:  Xiaowen Yu; Kaixuan Sheng; Gaoquan Shi
Journal:  Analyst       Date:  2014-09-21       Impact factor: 4.616

4.  Simultaneous determination of ascorbic acid, dopamine and uric acid using high-performance screen-printed graphene electrode.

Authors:  Jianfeng Ping; Jian Wu; Yixian Wang; Yibin Ying
Journal:  Biosens Bioelectron       Date:  2012-01-23       Impact factor: 10.618

5.  An ultra-specific and sensitive sandwich ELISA for imatinib using two anti-imatinib antibodies.

Authors:  Tetsuya Saita; Yuta Yamamoto; Kazuhisa Hosoya; Yutaro Yamamoto; Sakiko Kimura; Yutaka Narisawa; Masashi Shin
Journal:  Anal Chim Acta       Date:  2017-03-27       Impact factor: 6.558

6.  Investigation of the enzyme hydrolysis products of the substrates of alkaline phosphatase in electrochemical immunosensing.

Authors:  Anchana Preechaworapun; Zong Dai; Yun Xiang; Orawon Chailapakul; Joseph Wang
Journal:  Talanta       Date:  2008-03-25       Impact factor: 6.057

7.  Low-Cost Paper Electrode Fabricated by Direct Writing with Silver Nanoparticle-Based Ink for Detection of Hydrogen Peroxide in Wastewater.

Authors:  Archana Ghosale; Kamlesh Shrivas; Ravi Shankar; Vellaichamy Ganesan
Journal:  Anal Chem       Date:  2016-12-14       Impact factor: 6.986

8.  Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157:H7.

Authors:  Yixian Wang; Jianfeng Ping; Zunzhong Ye; Jian Wu; Yibin Ying
Journal:  Biosens Bioelectron       Date:  2013-06-11       Impact factor: 10.618

9.  Electrochemical acetylcholinesterase biosensor based on ZnO nanocuboids modified platinum electrode for the detection of carbosulfan in rice.

Authors:  Noel Nesakumar; Swaminathan Sethuraman; Uma Maheswari Krishnan; John Bosco Balaguru Rayappan
Journal:  Biosens Bioelectron       Date:  2015-11-09       Impact factor: 10.618

10.  Establishment of a reference interval for high-sensitivity cardiac troponin I in healthy adults from the Sichuan area.

Authors:  Shunjun Li; Yue Zuo; Wenfang Huang
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.