Nico Reinsch1, Ute Ruprecht2, Jochen Buchholz3, Rolf R Diehl4, Hagen Kälsch5, Kars Neven6. 1. Department of Electrophysiology, Alfried Krupp Krankenhaus, Essen, Germany; Witten/Herdecke University, Witten, Germany. Electronic address: nico.reinsch@krupp-krankenhaus.de. 2. Department of Electrophysiology, Alfried Krupp Krankenhaus, Essen, Germany; Department of Cardiology, Evangelisches Krankenhaus Werden, Essen, Germany; Witten/Herdecke University, Witten, Germany. 3. Department of Electrophysiology, Alfried Krupp Krankenhaus, Essen, Germany. 4. Department of Neurology, Alfried Krupp Krankenhaus, Essen, Germany. 5. Witten/Herdecke University, Witten, Germany; Department of Cardiology, Alfried Krupp Krankenhaus, Essen, Germany. 6. Department of Electrophysiology, Alfried Krupp Krankenhaus, Essen, Germany; Witten/Herdecke University, Witten, Germany.
Abstract
INTRODUCTION: Implantable loop recorders (ILR) are leadless subcutaneous devices that allow cardiac monitoring for up to 3 years and are a valuable tool in the diagnosis of arrhythmias, cryptogenic stroke and unexplained syncope. The Biotronik BioMonitor 2 is a novel, insertable ILR allowing long-term continuous monitoring with wireless telemetry options. METHODS: A single-center, prospective, observational study investigating the reliability of sensing quality and detection performance in the BioMonitor 2 ILR, as well as post-implantation patient satisfaction. R-wave amplitude was recorded immediately post implantation and 1 day post implantation, followed by extensive patient instruction. Follow-up was scheduled after 3 months, or after an event. Data from the ILR were retrieved, with documentation of all episodes, R-wave amplitude and noise burden. The anatomical position of the ILR was determined 1 day post implantation and after 3 months. A patient questionnaire was conducted after 3 months. RESULTS: 30 consecutive patients (mean age 71 ± 12 years, 56% male) were analyzed. Indications for ILR implantation were: unexplained syncope (n = 24, 80%), suspected atrial fibrillation (n = 4, 13%), cryptogenic stroke (n = 1, 3%) and palpitations (n = 1, 3%). Median time from skin cut to suture was 8 min. No complications occurred. Mean R-wave amplitude at implantation was 0.84 ± 0.32 mV, at day 1 post implantation 0.96 ± 0.31 mV, and after a mean follow-up of 85 ± 24 days 1.02 ± 0.47 mV (p = 0.01). The mean noise burden was 1.4 ± 2%. CONCLUSION: Implantation of the novel BioMonitor 2 ILR is fast and uncomplicated. Initial sensing values are good and improve over time.
INTRODUCTION: Implantable loop recorders (ILR) are leadless subcutaneous devices that allow cardiac monitoring for up to 3 years and are a valuable tool in the diagnosis of arrhythmias, cryptogenic stroke and unexplained syncope. The Biotronik BioMonitor 2 is a novel, insertable ILR allowing long-term continuous monitoring with wireless telemetry options. METHODS: A single-center, prospective, observational study investigating the reliability of sensing quality and detection performance in the BioMonitor 2 ILR, as well as post-implantation patient satisfaction. R-wave amplitude was recorded immediately post implantation and 1 day post implantation, followed by extensive patient instruction. Follow-up was scheduled after 3 months, or after an event. Data from the ILR were retrieved, with documentation of all episodes, R-wave amplitude and noise burden. The anatomical position of the ILR was determined 1 day post implantation and after 3 months. A patient questionnaire was conducted after 3 months. RESULTS: 30 consecutive patients (mean age 71 ± 12 years, 56% male) were analyzed. Indications for ILR implantation were: unexplained syncope (n = 24, 80%), suspected atrial fibrillation (n = 4, 13%), cryptogenic stroke (n = 1, 3%) and palpitations (n = 1, 3%). Median time from skin cut to suture was 8 min. No complications occurred. Mean R-wave amplitude at implantation was 0.84 ± 0.32 mV, at day 1 post implantation 0.96 ± 0.31 mV, and after a mean follow-up of 85 ± 24 days 1.02 ± 0.47 mV (p = 0.01). The mean noise burden was 1.4 ± 2%. CONCLUSION: Implantation of the novel BioMonitor 2 ILR is fast and uncomplicated. Initial sensing values are good and improve over time.