Literature DB >> 30175925

Optimising use of rate-of-change trend arrows for insulin dosing decisions using the FreeStyle Libre flash glucose monitoring system.

Ramzi A Ajjan1, Michael H Cummings2, Peter Jennings3, Lalantha Leelarathna4,5, Gerry Rayman6, Emma G Wilmot3.   

Abstract

Continuous glucose monitoring and flash glucose monitoring systems are increasingly used by people with diabetes on multiple daily injections of insulin and continuous subcutaneous insulin infusion. Along with real-time updates on current glucose levels, these technologies also use trend arrows to provide information on the direction and rate of change of glucose. Two systems, the Dexcom G5 and the FreeStyle Libre, have recently been approved for use without the need for adjunct capillary blood glucose, and there is a need for practical guidance for insulin dosing which incorporates rate of change in the insulin dosing algorithm. Here, we review the integration of rate of change trend arrow information into daily glucose management, including rapid-acting insulin dosing decisions. Based on the FreeStyle Libre flash glucose monitoring system, we also review a practical decision-support tool for actions to take when using trend arrows in conjunction with current glucose readings.

Entities:  

Keywords:  Continuous glucose monitoring; flash glucose monitoring; insulin dosing; interstitial fluid; rate of change; trend arrow

Mesh:

Substances:

Year:  2018        PMID: 30175925     DOI: 10.1177/1479164118795252

Source DB:  PubMed          Journal:  Diab Vasc Dis Res        ISSN: 1479-1641            Impact factor:   3.291


  5 in total

1.  Clinical Approach to Flash Glucose Monitoring: An Expert Recommendation.

Authors:  Ana Chico; Eva Aguilera; Francisco Javier Ampudia-Blasco; Virgina Bellido; Roque Cardona-Hernández; Francisco Javier Escalada; Diego Fernández; Fernando Gómez-Peralta; Noemí González Pérez de Villar; Juan José Gorgojo; Pedro Mezquita-Raya; Cristóbal Morales; Pedro de Pablos Velasco; Rafael Palomares; Juan Parra; María Teresa Rivero; Cintia González-Blanco
Journal:  J Diabetes Sci Technol       Date:  2019-05-12

2.  Study protocol: Safety and efficacy of smart watch integrated do-it-yourself continuous glucose monitoring in adults with Type 1 diabetes, a randomised controlled trial.

Authors:  Shekhar Sehgal; Martin De Bock; Jonathan Williman; Barry Taylor; Mona Elbalshy; Barbara Galland; Rosemary Hall; Ryan Paul; Alisa Boucsein; Shirley Jones; Carla Frewen; Benjamin J Wheeler
Journal:  J Diabetes Metab Disord       Date:  2021-10-31

3.  Use of flash glucose-sensing technology in patients with type 2 diabetes treated with liraglutide combined with CSII: a pilot study.

Authors:  Ming-Yan Yao; Li-Qin Li; Jian-Xia Ma; Peng Xue; Yu-Kun Li
Journal:  Braz J Med Biol Res       Date:  2019-12-20       Impact factor: 2.590

Review 4.  Use of continuous glucose monitoring trend arrows in the younger population with type 1 diabetes.

Authors:  Nancy Elbarbary; Othmar Moser; Saif Al Yaarubi; Hussain Alsaffar; Adnan Al Shaikh; Ramzi A Ajjan; Asma Deeb
Journal:  Diab Vasc Dis Res       Date:  2021 Nov-Dec       Impact factor: 3.291

Review 5.  Utilizing the New Glucometrics: A Practical Guide to Ambulatory Glucose Profile Interpretation.

Authors:  John Doupis; Edward S Horton
Journal:  touchREV Endocrinol       Date:  2022-06-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.