Precision of digital implant models compared to conventional implant models for posterior single implant crowns: A within-subject comparison.

Sven Mühlemann1, Elena A Greter1, Ji-Man Park2, Christoph H F Hämmerle1, Daniel S Thoma1.   

Abstract

OBJECTIVE: To calculate the precision of the implant analog position in digital models generated from different computer-assisted design and computer-assisted manufacturing (CAD-CAM) systems compared to gypsum models acquired from conventional implant impressions.
MATERIALS AND METHODS: In five patients in need of a single implant crown, a within-subject comparison was performed applying four different manufacturing processes for the implant model. Each implant was scanned with three different intraoral scanners: iTero Cadent (ITE), Lava True Definition (LTD), and Trios 3Shape (TRI). All digital implant models were fabricated using the corresponding certified CAD-CAM workflow. In addition, a conventional impression was taken (CON) and a gypsum model fabricated. Three consecutive impressions were acquired with each impression system. Following fabrication, all implant models were scanned. The datasets were aligned by a repeated best-fit algorithm and the precision for the implant analog and the adjacent teeth was measured. The precision served as a measure for reproducibility.
RESULTS: Mean precision values of the implant analog in the digital models were 57.2 ± 32.6 µm (ITE), 88.6 ± 46.0 µm (TRI), and 176.7 ± 120.4 µm (LTD). Group CON (32.7 ± 11.6 µm) demonstrated a statistically significantly lower mean precision value for the implant position in the implant model as compared to all other groups representing a high reproducibility. The mean precision values for the reference ranged between 31.4 ± 3.5 µm (TRI) and 39.5 ± 16.5 µm (ITE). No statistical significant difference was calculated between the four treatment groups.
CONCLUSIONS: The conventional implant model represented the greatest reproducibility of the implant position. Digital implant models demonstrated less precision compared to the conventional workflow.
© 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2018        PMID: 30168207     DOI: 10.1111/clr.13349

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

Review 2.  Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: A systematic review.

Authors:  Sven Mühlemann; Jenni Hjerppe; Christoph H F Hämmerle; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

3.  A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients.

Authors:  Francesco Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

Review 4.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 5.  Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies.

Authors:  María Isabel Albanchez-González; Jorge Cortés-Bretón Brinkmann; Jesús Peláez-Rico; Carlos López-Suárez; Verónica Rodríguez-Alonso; María Jesús Suárez-García
Journal:  Int J Environ Res Public Health       Date:  2022-02-11       Impact factor: 3.390

6.  Effect of Scanned Area and Operator on the Accuracy of Dentate Arch Scans with a Single Implant.

Authors:  Vinicius Rizzo Marques; Gülce Çakmak; Hakan Yilmaz; Samir Abou-Ayash; Mustafa Borga Donmez; Burak Yilmaz
Journal:  J Clin Med       Date:  2022-07-15       Impact factor: 4.964

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.