Literature DB >> 30160183

Contrast dose reduction with shortened injection durations in coronary CT angiography on 16-cm Wide-detector CT scanner.

Ting-Ting Qu1, Jian-Ying Li2, Xi-Jun Jiao1, Xiang-Li Zhang1, Zhe-Fan Song1, Yin-Xia Guo1, Jian-Xin Guo1.   

Abstract

OBJECTIVES: : To investigate the use of shortened contrast injection with late triggering in coronary CT angiography (CCTA) for decreasing contrast dose and maintaining image quality.
METHODS: : 106 patients for CCTA on a 16-cm wide-detector CT were prospectively enrolled into groups A (n = 50) and B (n = 56) randomly. Patient weight-dependent contrast medium (Iopamiro, 370 mgI ml-1) at dose rate of 25 mgI/kg/s was used with 8 s and the standard 10 s injection time in groups A and B, respectively. CT values of the aortic sinus (AS), right coronary artery, left anterior descending and left circumflex at the proximal, middle and distal segments were measured and compared. Subjective image quality was evaluated and analyzed with Fisher exact test. Contrast dose, injection rate and enhancement duration (between the start of enhancement in AS and scan finish) were also compared.
RESULTS: : There was no difference in the injection rate and enhancement duration between the two groups (p > 0.05), while the total contrast dose in group A (36.2 ± 5.7 ml) was significantly lower than in group B (46.4 ± 6.3 ml) (p < 0.001). There was no difference for CT values in all major coronary vessels between the two groups and no difference in subjective image quality scores (all p > 0.05).
CONCLUSION: : It is feasible to shorten contrast injection to 8 s in CCTA on wide-detector CT systems to significantly reduce contrast dosage, maintain adequate enhancement and reduce contrast-related artifacts. ADVANCES IN KNOWLEDGE:: (1) Coronary CT angiography (CCTA) scans with shortened contrast medium injection duration and late triggering are feasible with a 16-cm wide-detector CT system (2) Compared with the conventional CCTA with 10 s contrast injection duration, the new contrast injection protocol of using shortened injection duration (to 8 s) and late triggering reduces contrast dose to 36.2 ml, while maintaining adequate enhancement in vessels and reducing contrast-related artifacts.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30160183      PMCID: PMC6319827          DOI: 10.1259/bjr.20180580

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  23 in total

1.  Comparison between three supportive treatments for prevention of contrast-induced nephropathy in high-risk patients undergoing coronary angiography.

Authors:  Mohammad Reza Yeganehkhah; Leili Iranirad; Farshad Dorri; Soheila Pazoki; Hossein Akbari; Masoumeh Miryounesi; Mostafa Vahedian; Azam Nazeri; Fatemeh Hosseinzadeh; Jamshid Vafaeimanesh
Journal:  Saudi J Kidney Dis Transpl       Date:  2014-11

Review 2.  Present and future trends in multiple detector-row CT applications: CT angiography.

Authors:  Dominik Fleischmann
Journal:  Eur Radiol       Date:  2002-07       Impact factor: 5.315

3.  SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography.

Authors:  Gilbert L Raff; Aiden Abidov; Stephan Achenbach; Daniel S Berman; Lawrence M Boxt; Matthew J Budoff; Victor Cheng; Tony DeFrance; Jeffrey C Hellinger; Ronald P Karlsberg
Journal:  J Cardiovasc Comput Tomogr       Date:  2009-01-29

4.  Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight.

Authors:  Daniele Andreini; Saima Mushtaq; Edoardo Conte; Chiara Segurini; Marco Guglielmo; Maria Petullà; Valentina Volpato; Andrea Annoni; Andrea Baggiano; Alberto Formenti; Antonio L Bartorelli; Cesare Fiorentini; Mauro Pepi
Journal:  J Cardiovasc Comput Tomogr       Date:  2016-06-15

5.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

6.  Influence of hemodynamic parameters on coronary artery attenuation with 320-detector coronary CT angiography.

Authors:  Nobuo Tomizawa; Shuhei Komatsu; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Eur J Radiol       Date:  2011-01-14       Impact factor: 3.528

7.  Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT.

Authors:  Florence Orlandini; Stéphanie Boini; Sandrine Iochum-Duchamps; Toufik Batch; Xavier Zhu; Alain Blum
Journal:  AJR Am J Roentgenol       Date:  2006-08       Impact factor: 3.959

8.  Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT.

Authors:  Patrick A Hein; Juliane May; Patrik Rogalla; Craig Butler; Bernd Hamm; Alexander Lembcke
Journal:  Eur Radiol       Date:  2009-12-17       Impact factor: 5.315

9.  An initial randomised study assessing free-breathing CCTA using 320-detector CT.

Authors:  Eun-Ju Kang; Jongmin Lee; Ki-Nam Lee; Heejin Kown; Dong-Ho Ha; Rock Bum Kim
Journal:  Eur Radiol       Date:  2012-11-09       Impact factor: 5.315

10.  Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography.

Authors:  Yan Xing; Gulina Azati; Cun-xue Pan; Jun Dang; Sailendra Jha; Wen-ya Liu
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

View more
  3 in total

Review 1.  Network Medicine: A Clinical Approach for Precision Medicine and Personalized Therapy in Coronary Heart Disease.

Authors:  Teresa Infante; Luca Del Viscovo; Maria Luisa De Rimini; Sergio Padula; Pio Caso; Claudio Napoli
Journal:  J Atheroscler Thromb       Date:  2019-11-12       Impact factor: 4.928

2.  Low dose contrast media in step-and-shoot coronary angiography with third-generation dual-source computed tomography: feasibility of using 30 mL of contrast media in patients with body surface area <1.7 m2.

Authors:  Liang Jin; Bing Jie; Yiyi Gao; An'qi Jiang; Tingwen Weng; Ming Li
Journal:  Quant Imaging Med Surg       Date:  2021-06

3.  Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners.

Authors:  Liang Jin; Yiyi Gao; Yingli Sun; Cheng Li; Pan Gao; Wei Zhao; Ming Li
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.