| Literature DB >> 30154574 |
Camila R Koch1,2, Newton Kara-Junior3, Alicia Serra4, Marta Morales4.
Abstract
PURPOSE: To report the long-term outcome of early secondary intraocular lens (IOL) implantation following congenital cataract extraction in a large number of eyes.Entities:
Mesh:
Year: 2018 PMID: 30154574 PMCID: PMC6292907 DOI: 10.1038/s41433-018-0191-3
Source DB: PubMed Journal: Eye (Lond) ISSN: 0950-222X Impact factor: 3.775
Fig. 1The box plot shows the spherical equivalent according to the follow-up time in months. SE spherical equivalent, D dioptre
Results according to laterality
| Parameter | Bilateral ( | Unilateral ( | |||
|---|---|---|---|---|---|
| Mean ± SD | Range | Mean ± SD | Range | ||
| Age at cataract extraction (days) | 96.42 ± 42.93 | 27, 186 | 89.76 ± 49.34 | 20, 204 | 0.603 |
| Age at secondary IOL implantation (months) | 21.58 ± 5.92 | 11, 30 | 19.04 ± 5.9 | 11, 30 | 0.124 |
| AL at cataract surgery (mm) | 18.15 ± 1.34 | 16.25, 22.24 | 17.58 ± 1.18 | 15.73, 20.00 | 0.110 |
| AL at secondary IOL implantation (mm) | 20.24 ± 1.43 | 17.71, 24.07 | 20.34 ± 1.57 | 17.76, 22.82 | 0.810 |
| SE one month after IOL implantation (D) | 2.07 ± 3.52 | −4.00, 8.00 | 2.36 ± 2.21 | −1.50, 6.50 | 0.723 |
| SE at final follow-up (D) | −1.74 ± 3.74 | −8.25, 7.00 | −3.17 ± 4.96 | −16.50, 4.25 | 0.242 |
| Follow-up after secondary IOL implantation (months) | 79.96 ± 51.42 | 14, 189 | 87.04 ± 44.07 | 13, 164 | 0.596 |
| Age at last visit (months) | 102.56 ± 56.69 | 35, 217 | 106.48 ± 48.04 | 29, 197 | 0.789 |
| CDVA at last follow-up (LogMAR) | 0.48 ± 0.27 | 0.0, 1.3 | 0.76 ± 0.42 | 0.1, 1.3 | 0.002 |
| IOL power (D) | 26.14 ± 3.77 | 17, 30 | 25.00 ± 3.67 | 14, 31 | 0.260 |
CDVA corrected distance visual acuity, mm millimetre, D dioptre, IOL intraocular lens, SD standard deviation, AL axial length, logMAR: logarithm of the minimum angle of resolution
Results according to glaucoma complications before and after secondary IOL implantation in 12 (16%) of 75 eyes
| Type of glaucoma | Age at cataract surgery | Age at IOL implantation | CDVA at last follow-up | Surgical | ||
|---|---|---|---|---|---|---|
| OAG | ACG | (days) | (months) | (LogMAR) | cases | |
| (n%) | (n%) | Mean ± SD (range) | Mean ± SD (range) | Mean ± SD (range) | (n %) | |
| Glaucoma (eyes) | 9(75) | 3(25) | 84.58 ± 52.21 (27, 186) | 22.58 ± 5.51 (12, 29) | 0.93 ± 0.45 (0, 1.3) | 7(58.33) |
| Before IOL implantation | 3(25) | 0(0) | 47.67 ± 14.57 (31, 58) | 22.33 ± 5.03 (17, 27) | 1.23 ± 0.11 (1.1, 1.3) | 2(16.66) |
| After IOL implantation | 6(50) | 3(25) | 96.89 ± 54.90 (27, 186) | 22.67 ± 5.93 (12, 29) | 0.82 ± 0.48 (0, 1.3) | 5(41.66) |
OAG open-angle glaucoma, ACG angle-closure glaucoma, IOL intraocular lens, SD standard deviation