Literature DB >> 30154128

Reliability of Cardiorespiratory and Metabolic Responses During Incremental Shuttle Walk Test in Adult Subjects With Asthma.

Ivana Gonçalves Labadessa1, Audrey Borghi-Silva2, Adriana Sanches Garcia de Araujo2, Fabiola Paula Galhardo Rizzatti3, Valéria Amorim P Di Lorenzo2.   

Abstract

BACKGROUND: The incremental shuttle walk test (ISWT) has been widely used to assess exercise capacity of subjects with COPD. However, to date, no studies have assessed its reliability in the asthmatic population. This study aimed to assess the test-retest reliability of ISWT for the distance walked (ISWD) and cardiorespiratory and metabolic responses in adult subjects with asthma.
METHODS: This was a cross-sectional observational study. Thirty-four subjects of both genders, 18-45 y old, with a diagnosis of controlled asthma, were recruited from March 2012 to December 2015. The subjects performed 3 ISWTs on different days, with a minimum interval of 48 h and a maximum of 1 week between the second and third ISWT. For the reliability analysis, the values of the second and third ISWTs were used, eliminating the influence of any learning effect from the first test.
RESULTS: The intraclass correlation coefficients were > 0.75 (P < .001) for ISWD (m), speed (km/h),oxygen uptake (V̇O2 ), ventilatory equivalent carbon dioxide (V̇E/V̇CO2 ), and minute ventilation (V̇E) at the ISWT peak. The Bland-Altman plot presented a mean error close to zero, and measurement distribution was within acceptable limits of variation.
CONCLUSION: The ISWT presented excellent reliability for the ISWD and metabolic responses. The cardiorespiratory responses in the ISWTs presented good reliability. We concluded that the ISWT was reliable for young adult subjects with controlled asthma.
Copyright © 2019 by Daedalus Enterprises.

Entities:  

Keywords:  asthma; exercise test; metabolic stress response; physiotherapy; test-retest reliability; walking

Mesh:

Substances:

Year:  2018        PMID: 30154128     DOI: 10.4187/respcare.06112

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  2 in total

1.  Comparison of physiological responses after incremental shuttle walking test and 6-minute walk test in patients with systemic sclerosis.

Authors:  Buse Ozcan Kahraman; Aylin Tanriverdi; Nazenin Hande Sezgin; Serap Acar; Ahmet Merih Birlik; Aydan Koken Avsar; Bahri Akdeniz; Ebru Ozpelit; Sema Savci
Journal:  Wien Klin Wochenschr       Date:  2022-09-26       Impact factor: 2.275

2.  Modified Shuttle Test Distance Correlates With Peak Oxygen Uptake in Children and Adolescents With Severe Therapy-Resistant Asthma.

Authors:  Daniele Schiwe; João Paulo Heinzmann-Filho; Cláudia Silva Schindel; Mailise Fátima Gheller; Natália Evangelista Campos; Paulo Márcio Pitrez; Márcio Vinícius Fagundes Donadio
Journal:  Front Physiol       Date:  2019-10-01       Impact factor: 4.566

  2 in total