Literature DB >> 30151685

Determination of six benzotriazole ultraviolet filters in water and cosmetic samples by graphene sponge-based solid-phase extraction followed by high-performance liquid chromatography.

Xuemei Wang1,2, Juan Wang3, Tongtong Du3, Haixia Kou3, Xinzhen Du3,4, Xiaoquan Lu3,4.   

Abstract

An approach for fabrication of graphene sponge (GS)-based solid-phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) with ultraviolet detection (HPLC-UV) is proposed, which was applied to determine the six benzotriazole UV filters in water and cosmetic samples. Several extraction conditions including type of elution solvent, the volume of elution solvent, and salt effect were optimized. Under the optimum conditions, the GS-SPE-HPLC-UV method shows a low limit of detection (LOD, S/N = 3) of 0.02-0.08 μg L-1 for standard solution, limits of quantification (LOQ, S/N = 10) of 0.07-0.26 μg L-1 for standard solution, wide linear ranges from 20.0 to 1000 μg L-1 for all compounds for standard solution, correlation coefficients (r) of more than 0.999, except for 2-(2'-hydroxy-5'-methylphenyl)benzotriazole (UV-P), and acceptable reproducibility (relative standard deviations, RSDs < 6.5% for intra-day, RSDs < 8.1% for inter-day). The satisfactory recoveries were obtained in the range 89-105% with RSDs lower than 9.8% at the three spiked levels of 20, 50, and 100 μg L-1. Every home-made GS-SPE cartridge can be reused for more than 60 cycles. The method is facile, low-cost, rapid, sensitive, and suitable for the determination of UV filters in water and cosmetics samples. Graphical abstract ᅟ.

Entities:  

Keywords:  Benzotriazole; Graphene sponge (GS); High-performance liquid chromatography (HPLC); Solid-phase extraction (SPE); UV filters

Mesh:

Substances:

Year:  2018        PMID: 30151685     DOI: 10.1007/s00216-018-1301-6

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Degradation of Benzotriazole UV Stabilizers in PAA/d-Electron Metal Ions Systems-Removal Kinetics, Products and Mechanism Evaluation.

Authors:  Dariusz Kiejza; Joanna Karpińska; Urszula Kotowska
Journal:  Molecules       Date:  2022-05-23       Impact factor: 4.927

Review 2.  Use of Nanomaterial-Based (Micro)Extraction Techniques for the Determination of Cosmetic-Related Compounds.

Authors:  José Grau; Juan L Benedé; Alberto Chisvert
Journal:  Molecules       Date:  2020-06-02       Impact factor: 4.411

Review 3.  Sponges and Sponge-Like Materials in Sample Preparation: A Journey from Past to Present and into the Future.

Authors:  Theodoros G Chatzimitakos; Constantine D Stalikas
Journal:  Molecules       Date:  2020-08-12       Impact factor: 4.411

  3 in total