| Literature DB >> 30150601 |
Patrick C Setford1, David W Jeffery2,3, Paul R Grbin4,5, Richard A Muhlack6,7.
Abstract
Extraction of grape components is a key consideration for red winemaking. The impact of changing process variables on mass transfer properties of anthocyanins from fresh pre-fermentative red grape solids under forced convective conditions was explored using the dominant red grape anthocyanin, malvidin-3-glucoside (M3G) as a model solute. A two level full factorial design was implemented to investigate effects of temperature, sugar and ethanol on mass transfer properties. Factor levels were chosen to simulate conditions found at various points during the maceration and fermentation steps of the red winemaking process. A rigorous mathematical model was developed and applied to experimental extraction curves, allowing the separation of mass transport properties in liquid and solid phases in a wine-like system, for the first time. In all cases, the coefficient of determination exceeded 0.92, indicating good agreement between experimental and mathematically-solved M3G concentrations. For the conditions studied, internal mass transfer was found to limit M3G extraction and changes to the liquid phase composition and temperature influence the distribution constant. Surface response models of mass transfer parameters were developed to allow future simulations of fermentation scenarios aimed at maximising the extraction potential of M3G.Entities:
Keywords: anthocyanin; diffusion; mass transfer; phenolic extraction; process modelling; wine colour
Mesh:
Substances:
Year: 2018 PMID: 30150601 PMCID: PMC6225164 DOI: 10.3390/molecules23092159
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1Experimental and fitted models for malvidin-3-glucoside solid phase depletion (left) and liquid phase accumulation (right) at low temperature (upper) and high temperature (lower) conditions. ●, water; ■, 266 g/L glucose; ◆, 14% v/v ethanol; ▲, 266 g/L glucose and 14% v/v ethanol.
Figure 2Experimental and fitted model for malvidin-3-glucoside solid phase depletion (left) and liquid phase accumulation (right) at the factorial centre point conditions (12.2 °C, 133 g/L glucose and 7% ethanol). Error bars represent standard deviation.
Summary of mass transfer properties (, , , and ), Biot numbers () and statistical parameters ( and ) for malvidin-3-glucoside solved using the method outlined in Section 3.2 and Section 3.3.
| Trial Conditions | Diffusion and Mass Transfer Properties | Model Fit | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Temp. | Glucose | Ethanol |
|
|
|
| ||||
| Low | Low | Low | 4.68 × 10−12 | 1.89 × 10−4 | 6.04 × 10−14 | 7.09 × 10−11 | 4.01 × 10−2 | 2.18 × 104 | 0.955 | 0.978 |
| Low | Low | High | 2.76 × 10−12 | 1.20 × 10−4 | 1.29 × 10−13 | 1.51 × 10−10 | 9.95 × 10−2 | 1.62 × 104 | 1.073 | 0.990 |
| Low | High | Low | 2.14 × 10−12 | 9.79 × 10−4 | 5.67 × 10−14 | 6.65 × 10−11 | 4.01 × 10−2 | 1.20 × 104 | 0.765 | 0.984 |
| Low | High | High | 1.17 × 10−12 | 5.84 × 10−4 | 8.22 × 10−14 | 9.64 × 10−11 | 9.17 × 10−2 | 1.13 × 104 | 0.748 | 0.995 |
| Mid | Mid | Mid | 3.58 × 10−12 | 1.48 × 10−4 | 1.26 × 10−13 | 1.47 × 10−10 | 8.84 × 10−2 | 1.81 × 104 | 1.346 | 0.982 |
| High | Low | Low | 8.29 × 10−12 | 3.00 × 10−4 | 3.51 × 10−13 | 4.12 × 10−10 | 8.25 × 10−2 | 1.23 × 104 | 2.685 | 0.925 |
| High | Low | High | 5.71 × 10−12 | 2.18 × 10−4 | 7.55 × 10−13 | 8.85 × 10−10 | 1.41 × 10−1 | 7.05 × 103 | 1.062 | 0.993 |
| High | High | Low | 4.26 × 10−12 | 1.71 × 10−4 | 2.71 × 10−13 | 3.18 × 10−10 | 9.24 × 10−2 | 1.01 × 104 | 1.592 | 0.978 |
| High | High | High | 2.77 × 10−12 | 1.18 × 10−4 | 6.43 × 10−13 | 7.54 × 10−10 | 2.22 × 10−1 | 7.09 × 103 | 1.674 | 0.988 |
Full factorial analysis of variance (ANOVA) was conducted for experimentally determined parameters of solid-phase (internal) diffusivity (), solid phase (internal) mass transfer coefficient (), and distribution constant (), with factor effects and associated statistical significance shown in Table 2.
Factor effects and statistical significance of experimentally determined model parameters: solid-phase (internal) diffusivity (), solid phase (internal) mass transfer coefficient () and distribution constant ()
|
|
|
| ||||
|---|---|---|---|---|---|---|
| Coefficient | Factor Effect | Factor Effect | Factor Effect | |||
| Temp. (A) | 4.29 × 10−13 | 1.81 × 10−5 *** | 5.03 × 10−10 | 1.81 × 10−5 *** | 6.70 × 10−2 | 3.56 × 10−6 *** |
| Glucose (B) | −6.58 × 10−14 | 2.03 × 10−1 | −7.71 × 10−11 | 2.03 × 10−1 | 2.06 × 10−2 | 8.64 × 10−3 ** |
| Ethanol (C) | 2.17 × 10−13 | 1.84 × 10−3 ** | 2.54 × 10−10 | 1.84 × 10−3 ** | 7.49 × 10−2 | 1.53 × 10−6 *** |
| AB | −4.09 × 10−14 | 4.14 × 10−1 | −4.80 × 10−11 | 4.14 × 10−1 | 2.45 × 10−2 | 3.39 × 10−3 ** |
| AC | 1.70 × 10−13 | 7.28 × 10−3 ** | 1.99 × 10−10 | 7.28 × 10−3 ** | 1.93 × 10−2 | 1.19 × 10−2 * |
| BC | −1.77 × 10−14 | 7.18 × 10−1 | −2.08 × 10−11 | 7.18 × 10−1 | 1.58 × 10−2 | 2.91 × 10−2 * |
| ABC | 3.35 × 10−15 | 9.45 × 10−1 | 3.94 × 10−12 | 9.45 × 10−1 | 1.98 × 10−2 | 1.07 × 10−2 * |
*, ** and *** represent factors that are statistically significant at the 5%, 1% and 0.1% levels, respectively.
Figure 3Surface response of malvidin-3-glucoside internal diffusion coefficient, (upper) and distribution constant, (lower) at changing solvent conditions for low temperature (left) and high temperature (right) in the factorial design.
Summary of shape variables and physical properties of the system.
| Property or Shape Variable | Value | Source |
|---|---|---|
| 5747 | Mathematically derived | |
|
| 0.9173 | Experimentally determined |
| 6.987 × 10–1 | Experimentally determined | |
| 1.74 × 10–4 | Jin et al. [ | |
| 0.5259 | Geankoplis [ | |
| Varied | Experimentally determined | |
| Varied | HYSYS (Hysys, Operations Guide., 2005) | |
| Varied | Equation (19) | |
|
| Varied | Equation (20) |