Literature DB >> 30150047

Effect of integrating digital breast tomosynthesis (3D-mammography) with acquired or synthetic 2D-mammography on radiologists' true-positive and false-positive detection in a population screening trial: A descriptive study.

Daniela Bernardi1, Tong Li2, Marco Pellegrini3, Petra Macaskill4, Marvi Valentini5, Carmine Fantò6, Livio Ostillio7, Nehmat Houssami8.   

Abstract

BACKGROUND: We previously reported the Screening with tomosynthesis or standard mammography-2 (STORM-2) trial, showing that tomosynthesis (3D-mammography) screening detected more cancers than 2D-mammography in double-reading practice. In this study, we report reader-specific detection measures for radiologists who performed the screen-reading in this trial.
METHODS: This is a sub-study of the STORM-2 trial which prospectively integrated 3D-mammography with acquired or synthetized 2D-mammograms in parallel double-reading arms. Asymptomatic women ≥49 years who attended population-based screening (Trento, 2013-2015) were recruited. Screening participants were recalled at any positive sequential screen-read in either reading arm of the trial. Radiologist-specific detection measures were calculated for each of seven radiologists who performed screen-reads: number of detected cancers, proportion of true-positive (TP) detection, and number and rate of false-positive (FP) recalls (FPR). We estimated incremental cancer detection rate (CDR) from integrating 3D-mammography in screen-reading.
RESULTS: Across all radiologists, TP detection (relative sensitivity) ranged between: 46% and 100% (median 59.5%) for 2D-mammography; 75% and 100% (median 76%) for integrated 2D/3D-mammography screening; 56% and 76% (median 64%) for 2Dsynthetic; 67% and 88% (median 78%) for 2Dsynthetic/3D-mammography. Integrating 3D-mammography led to incremental CDRs between 0/1000 and 3.5/1000 screens. FPR ranged between: 1.2% and 2.7% (median 2.25%) for 2D-mammography; 1.5% and 3.4% (median 2.75%) for 2D/3D-mammography; 1.6% and 4.6% (median 2.4%) for 2Dsynthetic; and 1.8% and 6.7% (median 3.0%) for 2Dsynthetic/3D-mammography.
CONCLUSIONS: There was variability in the magnitude of effect from integrating 3D-mammography (relative to screen-reading with acquired or synthesised 2D-mammography alone) on individual radiologist's TP and FP detection, although there was an overall pattern of increasing cancer detection and also increasing FP recall for most readers.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Breast cancer screening; Digital breast tomosynthesis; Mammography; Population screening; Screen-reading

Mesh:

Year:  2018        PMID: 30150047     DOI: 10.1016/j.ejrad.2018.07.008

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  4 in total

1.  A collection input based support tensor machine for lesion malignancy classification in digital breast tomosynthesis.

Authors:  Benjuan Yang; Yingjiang Wu; Zhiguo Zhou; Shulong Li; Genggeng Qin; Liyuan Chen; Jing Wang
Journal:  Phys Med Biol       Date:  2019-12-05       Impact factor: 3.609

2.  Breast Cancer Screening Among Medically Underserved Women in New Mexico: Potential for Lower Recall Rates with Digital Breast Tomosynthesis.

Authors:  Martha T Manda-Mapalo; Stephanie G Fine; Sarah Safadi; Ji-Hyun Lee; Ruofei Du; Andrew L Sussman; Shiraz Mishra; Reed G Selwyn; Jennifer L Saline; Wendy L Hine; Ursa A Brown-Glaberman
Journal:  J Womens Health (Larchmt)       Date:  2020-09-29       Impact factor: 2.681

3.  Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis.

Authors:  Mostafa Alabousi; Akshay Wadera; Mohammed Kashif Al-Ghita; Rayeh Kashef Al-Ghetaa; Jean-Paul Salameh; Alex Pozdnyakov; Nanxi Zha; Lucy Samoilov; Anahita Dehmoobad Sharifabadi; Behnam Sadeghirad; Vivianne Freitas; Matthew Df McInnes; Abdullah Alabousi
Journal:  J Natl Cancer Inst       Date:  2021-06-01       Impact factor: 13.506

Review 4.  The role of digital breast tomosynthesis in breast cancer screening: a manufacturer- and metrics-specific analysis.

Authors:  A Hadjipanteli; M Kontos; A Constantinidou
Journal:  Cancer Manag Res       Date:  2019-10-31       Impact factor: 3.989

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.