Literature DB >> 30147740

B-Flow imaging of the placenta: A feasibility study.

Manjiri K Dighe1, Mariam Moshiri1, Jennifer Jolley2, Jeff Thiel1, Dan Hippe1.   

Abstract

B-Flow imaging directly displays the flowing intravascular echoes during real-time gray-scale ultrasound without using Doppler techniques. The objective of our study was to evaluate the feasibility of B-Flow imaging in the placenta and to evaluate the artifacts seen on B-Flow imaging. After IRB approval, 36 women (17 normal and 19 high risk women) were enrolled in our study. B-Flow images were acquired on GE LOGIC E9 machine. Retrospective analysis of the B-Flow and cine capture images was performed for artifacts and for vessels visualized. Pregnant women enrolled in the study ranged from 19 to 43 years of age with an average age of 31.7 years. Gestational age varied from 17 weeks and five days to 36 weeks and three days with an average of 26 weeks and three days. From a total of 161 B-Flow images reviewed by one researcher, 15 images were acceptable with no evidence of artifact. The remainder of the images had some artifact in them. For the 36 women with color Doppler and B-Flow images reviewed by the two independent blinded reviewers, a total of 144 reads were obtained. More small horizontal (p = 0.046) and small vertical running vessels (p < 0.001) were identified with B-Flow than color Doppler images. B-Flow is capable of showing perfusion in a human placenta; however, recognizing artifacts and modifying the image acquisition to reduce artifacts is necessary with this new technique to acquire the best images for interpretation.

Entities:  

Keywords:  B-Flow; Doppler; placenta; pregnancy

Year:  2018        PMID: 30147740      PMCID: PMC6099763          DOI: 10.1177/1742271X18768841

Source DB:  PubMed          Journal:  Ultrasound        ISSN: 1742-271X


  24 in total

Review 1.  Endovascular trophoblast invasion: implications for the pathogenesis of intrauterine growth retardation and preeclampsia.

Authors:  Peter Kaufmann; Simon Black; Berthold Huppertz
Journal:  Biol Reprod       Date:  2003-03-05       Impact factor: 4.285

2.  Venous Doppler in the prediction of acid-base status of growth-restricted fetuses with elevated placental blood flow resistance.

Authors:  Ahmet A Baschat; Serkan Güclü; Michelle L Kush; Ulrich Gembruch; Carl P Weiner; Chris R Harman
Journal:  Am J Obstet Gynecol       Date:  2004-07       Impact factor: 8.661

3.  Transvaginal color Doppler assessment of the uteroplacental circulation in early pregnancy.

Authors:  D Jurkovic; E Jauniaux; A Kurjak; J Hustin; S Campbell; K H Nicolaides
Journal:  Obstet Gynecol       Date:  1991-03       Impact factor: 7.661

4.  Ultrasound B-flow imaging in the evaluation of thermal ablation of thyroid nodules.

Authors:  Massimiliano Andrioli; Roberto Valcavi
Journal:  Endocrine       Date:  2014-06-01       Impact factor: 3.633

5.  B-flow imaging estimation of carotid and femoral atherosclerotic plaques: vessel walls rheological damage or strong predictor of cardiovascular mortality in chronic dialysis patients.

Authors:  Petar Avramovski; Maja Avramovska; Aleksandar Sikole
Journal:  Int Urol Nephrol       Date:  2016-08-11       Impact factor: 2.370

6.  ASPRE trial: performance of screening for preterm pre-eclampsia.

Authors:  D L Rolnik; D Wright; L C Y Poon; A Syngelaki; N O'Gorman; C de Paco Matallana; R Akolekar; S Cicero; D Janga; M Singh; F S Molina; N Persico; J C Jani; W Plasencia; G Papaioannou; K Tenenbaum-Gavish; K H Nicolaides
Journal:  Ultrasound Obstet Gynecol       Date:  2017-08-24       Impact factor: 7.299

7.  Combined use of color duplex ultrasonography and B-flow imaging for evaluation of patients with carotid artery stenosis.

Authors:  Muharrem Tola; Mehmet Yurdakul; Turhan Cumhur
Journal:  AJNR Am J Neuroradiol       Date:  2004 Nov-Dec       Impact factor: 3.825

8.  Doppler velocimetry of intraplacental fetal vessels in the second trimester: improving the prediction of pregnancy complications in high-risk patients.

Authors:  R Jaffe; J R Woods
Journal:  Ultrasound Obstet Gynecol       Date:  1996-10       Impact factor: 7.299

Review 9.  Doppler application in the delivery timing of the preterm growth-restricted fetus: another step in the right direction.

Authors:  A A Baschat
Journal:  Ultrasound Obstet Gynecol       Date:  2004-02       Impact factor: 7.299

Review 10.  The global impact of pre-eclampsia and eclampsia.

Authors:  Lelia Duley
Journal:  Semin Perinatol       Date:  2009-06       Impact factor: 3.300

View more
  2 in total

1.  Characterization of Testicular Tumor Lesions in Dogs by Different Ultrasound Techniques.

Authors:  Riccardo Orlandi; Emanuela Vallesi; Cristiano Boiti; Angela Polisca; Paolo Bargellini; Alessandro Troisi
Journal:  Animals (Basel)       Date:  2022-01-17       Impact factor: 2.752

2.  B-flow/spatiotemporal image correlation M-mode: novel ultrasound method that detects decrease in spiral artery luminal diameter in first trimester in primate model of impaired spiral artery remodeling.

Authors:  O M Turan; J S Babischkin; G W Aberdeen; S Turan; C R Harman; G J Pepe; E D Albrecht
Journal:  Ultrasound Obstet Gynecol       Date:  2022-03       Impact factor: 8.678

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.