Wendel Wohlleben1, Christopher Kingston2, Janet Carter3, E Sahle-Demessie4, Socorro Vázquez-Campos5, Brad Acrey6,7, Chia-Ying Chen6,8, Ernest Walton9, Heiko Egenolf1, Philipp Müller1, Richard Zepp6.
Abstract
A major use of multi-walled carbon nanotubes (Entities:
Year: 2017 PMID: 30147114 PMCID: PMC6104645 DOI: 10.1016/j.carbon.2016.11.011
Source DB: PubMed Journal: Carbon N Y ISSN: 0008-6223 Impact factor: 9.594
Fig. 1.ILC organization with 4 labs to perform the aging, and 2 labs to perform the wet immersion sampling and TEM/UVeVis/ICP-MS/AUC/AF4 analysis on specimen from all 4 aging labs, 2 labs to perform dry sampling and SEM/EDX analysis. (A colour version of this figure can be viewed online.)
Fig. 2.Characterization of the positive control samples of pure MWCNT dispersed in the immersion fluid via sonication. A) TEM of 10 ppm MWCNT; B) UVeVis and C) AUC each of immersion fluid with 0 ppm (grey line), 1 ppm (black solid line), 10 ppm (black dashed line) and 100 ppm (black dotted line) MWCNT. For C), the size is represented as cumulative distributions (thick lines, right axis), highlighting the match of nominal and measured concentration.
Fig. 3.Protocol summary. The exact instrumentation and procedures in EPA-Ath and BASF labs are described in the text. Photographs were taken at the BASF sampling labs. As indicated in the figure, 4 mL aliquots each were taken from the pH 4.93 immersion fluid following mild agitation in the shaker, and then from the sonicated extract. Aliquots were then analyzed. The samples analyzed by UV–vis and AUC/AF4 were pretreated by adding 1% (v.v.) sodium dodecyl sulfonate (SDS) followed by an additional 1 h bath sonication to reduce sample agglomeration. (A colour version of this figure can be viewed online.)
Fig. 7.TEM comparison of aging labs on the samples with lowest release (P4 shaker) and highest release (E4 sonication). A) schematic; B) sampled and analyzed at EPA; C) sampled and analyzed at BASF. The analysis is based on duplicate wafers that were each aged, sampled and analyzed. The units of the y-axis are “%”. (A colour version of this figure can be viewed online.)
Fig. 4.Representative SEM images of samples collected from the weathered surfaces of the 4%-wt MWCNT-polyamide (PA4) specimens (A–D) and the 0.25%-wt MWCNT-epoxy (E4) specimens (E–H). Images A) and E) are of samples of specimens aged by BASF, B) and F) aged by LEITAT, C) and G) aged by EPA-Ath, and D) and H) aged by EPA-Cin.
Fig. 5.ICP-MS comparison of aging labs on the samples with lowest release (P4 shaker) and of highest release (E4 sonication). A) sampled and analyzed at EPA-Ath (black); B) sampled and analyzed at BASF (red). (A colour version of this figure can be viewed online.)
Fig. 8.UVeVis comparison of aging labs on the samples with lowest release (P4 shaker) and highest release (E4 sonication). A) absorption at 260 nm, measured at EPA on diluted samples; B) shift of the wavelength at which absorption drops below 1, vs pure fluid control, measured at BASF on undiluted samples. The error bars reflect duplicate wafers that were each aged, sampled and analyzed. A more conventional evaluation of the same spectra (absorption at 450 nm, undiluted) is correlated against the absorption at 260 nm (diluted) in the discussion. For original spectra see Fig. SI_11. (A colour version of this figure can be viewed online.)
Fig. 6.Exemplary BF-TEM images of sonicated P4 and E4 samples aged at different labs (rows) and imaged at BASF or EPA-Ath (columns).
Fig. 9.AUC results from analysis at BASF. A) size distributions of positive control (1 ppm MWCNT, black line), negative control (pure fluid, grey line), E4 (red line), E0 (red dots), P4 (blue line), P0 (blue dots), all with sonication sampling, showing weak differentiation of samples from baseline, except E4; B) cumulative content in the size range 5 nm–100 nm, comparing aging labs on the samples with lowest release (P4 shaker) and highest release (E4 sonication). The error bars reflect duplicate wafers that were each aged, sampled and analyzed. (A colour version of this figure can be viewed online.)
Fig. 10.Comparison of materials (epoxy vs. PA), including effect of added MWCNT (EO vs E4, P0 vs P4), and mechanical stress on release (shaker vs sonication). A) TEM at EPA-Ath; B) TEM at BASF, with color coding of the form of release as defined in Fig. 7A. C) UVeVis analysis; EPA absorbance at 260 nm diluted (black), BASF absorbance at 450 nm undiluted (green), BASF shift of the wavelength at which absorbance equals 1 (red, right-hand axis). D) ICP-MS analysis; EPA (black), BASF (red). Lower values of P4 analyzed at EPA are rationalized by the omission of acid digestion here, in contrast to the analysis of E4 that used acid digestion in both analysis labs. Further, P4 suffers from Co contaminations (Table SI_1), making it less suitable for ICP-MS comparison. Data obtained from N = 8 specimens (duplicates from each of the four aging labs) have been averaged separately for each analysis lab. All data are represented, with no outliers removed. Error bars indicate one standard deviation. (A colour version of this figure can be viewed online.)