Alessia Giaquinta1, Vincenzo Ardita1, Ciro Ferrer2, Clive B Beggs3, Massimiliano Veroux1, Matteo Barbante4, Matteo Orrico5, Piergiorgio Cao6, Piefrancesco Veroux1. 1. 1 Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Italy. 2. 2 Department of Surgery "Pietro Valdoni," "Sapienza" University, Rome, Italy. 3. 3 Research Institute for Sport, Physical Activity and Leisure, Carnegie Faculty, Leeds Beckett University, Leeds, UK. 4. 4 Vascular Surgery Unit, Department of Biomedicine and Prevention, University of Rome "Tor Vergata," Rome, Italy. 5. 5 Department of Vascular Surgery, San Filippo Neri Hospital, Rome, Italy. 6. 6 Division of Vascular Surgery, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
Abstract
PURPOSE: To assess early and midterm outcomes of iliac branch device (IBD) implantation without an aortic stent-graft for the treatment of isolated common iliac artery aneurysm (CIAA). METHODS: From December 2006 to June 2016, 49 isolated CIAAs in 46 patients were treated solely with an IBD at 7 vascular centers. Five patients were lost to follow-up, leaving 41 male patients (mean age 72.5±7.8 years) for analysis. Mean CIAA diameter was 39.1±10.5 mm (range 25-65). Thirty-two patients (2 with bilateral CIAAs) were treated with a Cook Zenith iliac branch device; 9 patients (1 bilateral) received a Gore Excluder iliac branch endoprosthesis. Primary endpoints were technical success, survival, aneurysm exclusion, device patency, and freedom from reintervention at 1 and 5 years. Freedom from major adverse events and aneurysm shrinkage at 1 year were also assessed. RESULTS: Thirty-day mortality and the IBD occlusion rate were 2.4% and 2.3%, respectively. At a mean follow-up of 40.2±33.9 months, no patient presented buttock claudication, erectile dysfunction, or bowel or spinal cord ischemia. Three patients died within 6 months after the procedure. Estimates of cumulative survival, device patency, and freedom from reintervention were 90.2%, 95.2%, and 95.7%, respectively, at 1 and 5 years. At 1 year, CIAA shrinkage ≥5 mm was recorded in 21 of 38 survivors. No evidence of endoleak, device migration, or disconnection was found on imaging follow-up. CONCLUSION: The use of IBDs without an aortic stent-graft for isolated CIAAs resulted in excellent patency, with low morbidity and mortality. This, in conjunction with no endoleak or migration and a low reintervention rate, supports the use of isolated IBDs as a stable and durable means of endovascular reconstruction in cases with suitable anatomy. Longer follow-up and a larger cohort are needed to validate these results.
PURPOSE: To assess early and midterm outcomes of iliac branch device (IBD) implantation without an aortic stent-graft for the treatment of isolated common iliac artery aneurysm (CIAA). METHODS: From December 2006 to June 2016, 49 isolated CIAAs in 46 patients were treated solely with an IBD at 7 vascular centers. Five patients were lost to follow-up, leaving 41 male patients (mean age 72.5±7.8 years) for analysis. Mean CIAA diameter was 39.1±10.5 mm (range 25-65). Thirty-two patients (2 with bilateral CIAAs) were treated with a Cook Zenith iliac branch device; 9 patients (1 bilateral) received a Gore Excluder iliac branch endoprosthesis. Primary endpoints were technical success, survival, aneurysm exclusion, device patency, and freedom from reintervention at 1 and 5 years. Freedom from major adverse events and aneurysm shrinkage at 1 year were also assessed. RESULTS: Thirty-day mortality and the IBD occlusion rate were 2.4% and 2.3%, respectively. At a mean follow-up of 40.2±33.9 months, no patient presented buttock claudication, erectile dysfunction, or bowel or spinal cord ischemia. Three patients died within 6 months after the procedure. Estimates of cumulative survival, device patency, and freedom from reintervention were 90.2%, 95.2%, and 95.7%, respectively, at 1 and 5 years. At 1 year, CIAA shrinkage ≥5 mm was recorded in 21 of 38 survivors. No evidence of endoleak, device migration, or disconnection was found on imaging follow-up. CONCLUSION: The use of IBDs without an aortic stent-graft for isolated CIAAs resulted in excellent patency, with low morbidity and mortality. This, in conjunction with no endoleak or migration and a low reintervention rate, supports the use of isolated IBDs as a stable and durable means of endovascular reconstruction in cases with suitable anatomy. Longer follow-up and a larger cohort are needed to validate these results.