Literature DB >> 30139603

In-vivo EPID dosimetry for IMRT and VMAT based on through-air predicted portal dose algorithm.

M A Najem1, M Tedder2, D King3, D Bernstein3, R Trouncer3, C Meehan3, A M Bidmead3.   

Abstract

We have adapted the methodology of Berry et al. (2012) for Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) treatments at a fixed source to imager distance (SID) based on the manufacturer's through-air portal dose image prediction algorithm. In order to fix the SID a correction factor was introduced to account for the change in air gap between patient and imager. Commissioning data, collected with multiple field sizes, solid water thicknesses and air gaps, were acquired at 150 cm SID on the Varian aS1200 EPID. The method was verified using six IMRT and seven VMAT plans on up to three different phantoms. The method's sensitivity and accuracy were investigated by introducing errors. A global 3%/3 mm gamma was used to assess the differences between the predicted and measured portal dose images. The effect of a varying air gap on EPID signal was found to be significant - varying by up to 30% with field size, phantom thickness, and air gap. All IMRT plans passed the 3%/3 mm gamma criteria by more than 95% on the three phantoms. 23 of 24 arcs from the VMAT plans passed the 3%/3 mm gamma criteria by more than 95%. This method was found to be sensitive to a range of potential errors. The presented approach provides fast and accurate in-vivo EPID dosimetry for IMRT and VMAT treatments and can potentially replace many pre-treatment verifications.
Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30139603     DOI: 10.1016/j.ejmp.2018.07.010

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

1.  A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device.

Authors:  Jun Zhang; Xiuqing Li; Miaomiao Lu; Qilin Zhang; Xile Zhang; Ruijie Yang; Maria F Chan; Junhai Wen
Journal:  Radiat Oncol       Date:  2021-12-04       Impact factor: 3.481

2.  A feasibility study for in vivo treatment verification of IMRT using Monte Carlo dose calculation and deep learning-based modelling of EPID detector response.

Authors:  Jun Zhang; Zhibiao Cheng; Ziting Fan; Qilin Zhang; Xile Zhang; Ruijie Yang; Junhai Wen
Journal:  Radiat Oncol       Date:  2022-02-10       Impact factor: 3.481

3.  A transit portal dosimetry method for respiratory gating quality assurance with a dynamic 3D printed tumor phantom.

Authors:  Hong Qi Tan; Calvin Wei Yang Koh; Lloyd Kuan Rui Tan; Kah Seng Lew; Clifford Ghee Ann Chua; Khong Wei Ang; James Cheow Lei Lee; Sung Yong Park
Journal:  J Appl Clin Med Phys       Date:  2022-02-11       Impact factor: 2.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.