Literature DB >> 30139539

High intensity focused ultrasound cyclodestruction versus cyclodiode treatment of refractory glaucoma: A retrospective comparative study.

M Graber1, P-R Rothschild2, Z Khoueir3, E Bluwol3, N Benhatchi3, Y Lachkar3.   

Abstract

PURPOSE: To compare the efficacy of two cyclodestructive treatments for refractory glaucoma: High Intensity Focused Ultrasound (HIFU) cyclocoagulation and transscleral diode laser cyclophotocoagulation (cyclodiode).
METHODS: A retrospective comparative single centre study including all patients who underwent cyclodestruction for refractory glaucoma by either HIFU cyclocoagulation or cyclodiode. "Refractory glaucoma" was defined as an uncontrolled high IOP despite medical treatment and at least one filtering surgery. Uncontrolled high IOP was defined as an IOP≥16mm Hg. The diagnosis of glaucoma was confirmed by automated visual field (VF) testing and peripapillary RNFL scans using a time-domain ocular coherence tomography device. Treatment success was defined as: postoperative IOP between 5mm Hg and 21mm Hg and IOP reduction greater than or equal to 20% as compared to preoperative values.
RESULTS: Among the 99 eyes of 86 patients included in this study, 29 eyes were treated by cyclodiode and 70 eyes by HIFU. Median follow-up was 3 months (IQR 3-6) for the cyclodiode group and 6 months (IQR 3-8) for the HIFU group. Average preoperative intraocular pressure (IOP) was 34.3±11.1mm Hg (cyclodiode group) and 23±6.8mm Hg (HIFU group). The treatment success rate at last follow-up was 52% [34-70] for the cyclodiode group and 25% [15-35] for the HIFU group (P value=0.01). Kaplan-Meier survival analysis showed that the mean estimated time to failure was 5.9 months (4.4-7.5) for the cyclodiode group and 3.7 months (2.8-4.7) for the HIFU group (log-Rank test, P=0.02). A 2-line visual acuity loss was observed for 31% of the patients treated by cyclodiode and 17% for those treated by HIFU. In the cyclodiode group 4 cases of hypotony were reported vs. none in the HIFU group.
CONCLUSIONS: The success rate was significantly higher for cyclodiode treatment as compared to HIFU cyclodestruction when treating refractory glaucoma. However, significantly fewer complications were observed with HIFU cyclocoagulation as compared to cyclodiode.
Copyright © 2018 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Cyclodestruction; Cyclodiode; Cyclophotocoagulation; Glaucome réfractaire; HIFU; High intensity focused ultrasound; Refractory glaucoma; Ultrasons focalisés de haute intensité

Mesh:

Year:  2018        PMID: 30139539     DOI: 10.1016/j.jfo.2018.02.005

Source DB:  PubMed          Journal:  J Fr Ophtalmol        ISSN: 0181-5512            Impact factor:   0.818


  4 in total

1.  Efficacy and safety of high-dose ultrasound cyclo-plasty procedure in refractory glaucoma.

Authors:  He-Ting Liu; Qing Zhang; Zheng-Xuan Jiang; Yu-Xin Xu; Qian-Qian Wan; Li-Ming Tao
Journal:  Int J Ophthalmol       Date:  2020-09-18       Impact factor: 1.779

2.  Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma.

Authors:  Di Chen; Xiu-Juan Guo; Shu-Ke Luo; Yan Lu; Xiu-Rong Tang
Journal:  BMC Ophthalmol       Date:  2022-10-07       Impact factor: 2.086

3.  A Comparative Study between Ultrasound Cycloplasty and Cyclocryotherapy for the Treatment of Neovascular Glaucoma.

Authors:  Wang Ruixue; Wang Tao; Li Ning
Journal:  J Ophthalmol       Date:  2020-01-22       Impact factor: 1.909

4.  Comparison of ultrasound cycloplasty and transscleral cyclophotocoagulation for refractory glaucoma in Chinese population.

Authors:  Qiuli Yu; Ya Liang; Fangfang Ji; Zhilan Yuan
Journal:  BMC Ophthalmol       Date:  2020-09-29       Impact factor: 2.209

  4 in total