Literature DB >> 30139483

Esophageal Deviation During Atrial Fibrillation Ablation: Clinical Experience With a Dedicated Esophageal Balloon Retractor.

Rahul Bhardwaj1, Aditi Naniwadekar2, William Whang2, Alexander J Mittnacht2, Chandrasekar Palaniswamy3, Jacob S Koruth2, Kamal Joshi2, Aamir Sofi2, Marc Miller2, Subbarao Choudry2, Srinivas R Dukkipati2, Vivek Y Reddy4.   

Abstract

OBJECTIVES: The goal of this study was to determine the safety and feasibility of a novel esophageal balloon retractor (DV8) for MED during PVI.
BACKGROUND: The authors previously showed that mechanical esophageal deviation (MED) is feasible using an off-the-shelf metal stylet to allow uninterrupted ablation along the posterior left atrium during pulmonary vein isolation (PVI). Although it is an attractive strategy to avoid esophageal thermal injury, this technique was hampered by both the propensity for oropharyngeal trauma from the stiff stylet and the limited lateral esophageal displacement.
METHODS: In 200 consecutive patients undergoing atrial fibrillation ablation, the DV8 balloon retractor was used for MED; contrast was instilled into the esophagus to accurately delineate the trailing esophageal edge. Deviation was performed to maximize the distance from the trailing esophageal edge to the closest point of the ablation line (MEDEffective) and correlated to occurrences of luminal esophageal temperature elevation.
RESULTS: In patients undergoing MED during a first-ever PVI of 304 vein pairs, the MEDEffective during right and left PVI were 21.2 ± 8.7 mm and 15.5 ± 6.8 mm, respectively. Deviation of at least 5 mm of MEDEffective was achievable in 97.7%. Luminal esophageal temperature increases universally occurred (100%) at MEDEffective <5 mm, less often (28%) at MEDEffective 5 to 20 mm, and rarely (1.9%) at MEDEffective >20 mm. There were no esophageal complications, but 2 patients experienced oropharyngeal bleeding due to trauma related to device placement.
CONCLUSIONS: MED with the balloon retractor safely moved the esophagus away from the site of energy delivery during atrial fibrillation ablation.
Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  atrial fibrillation ablation; esophageal deviation; esophagus

Mesh:

Year:  2018        PMID: 30139483     DOI: 10.1016/j.jacep.2018.04.001

Source DB:  PubMed          Journal:  JACC Clin Electrophysiol        ISSN: 2405-500X


  7 in total

1.  Preventing esophageal complications from atrial fibrillation ablation: A review.

Authors:  Lisa W M Leung; Zaki Akhtar; Mary N Sheppard; John Louis-Auguste; Jamal Hayat; Mark M Gallagher
Journal:  Heart Rhythm O2       Date:  2021-09-22

2.  Radiofrequency ablation data associated with atrioesophageal fistula.

Authors:  David R Tomlinson; John Mandrola
Journal:  HeartRhythm Case Rep       Date:  2021-12-15

Review 3.  Prevention and Treatment of Atrioesophageal Fistula Related to Catheter Ablation for Atrial Fibrillation.

Authors:  George M Bodziock; Caleb A Norton; Jay A Montgomery
Journal:  J Innov Card Rhythm Manag       Date:  2019-05-15

4.  Esophageal temperature during atrial fibrillation ablation poorly predicts esophageal injury: An observational study.

Authors:  Tarek Ayoub; Abdel Hadi El Hajjar; Gursukhman Deep Singh Sidhu; Arezu Bhatnagar; Yichi Zhang; Mario Mekhael; Charbel Noujaim; Lilas Dagher; Christopher Pottle; Nassir Marrouche
Journal:  Heart Rhythm O2       Date:  2021-11-05

Review 5.  Protecting Against Collateral Damage to Non-cardiac Structures During Endocardial Ablation for Persistent Atrial Fibrillation.

Authors:  Lisa Wm Leung; Zaki Akhtar; Jamal Hayat; Mark M Gallagher
Journal:  Arrhythm Electrophysiol Rev       Date:  2022-04

6.  Survival of a Patient with an Esophagopericardial Fistula After Catheter Ablation for Atrial Fibrillation: A Case Report and Literature Review.

Authors:  Granit Veseli; Sei Iwai; Jason T Jacobson
Journal:  J Innov Card Rhythm Manag       Date:  2020-05-15

7.  Randomized comparison of oesophageal protection with a temperature control device: results of the IMPACT study.

Authors:  Lisa W M Leung; Abhay Bajpai; Zia Zuberi; Anthony Li; Mark Norman; Riyaz A Kaba; Zaki Akhtar; Banu Evranos; Hanney Gonna; Idris Harding; Manav Sohal; Nawaf Al-Subaie; John Louis-Auguste; Jamal Hayat; Mark M Gallagher
Journal:  Europace       Date:  2021-02-05       Impact factor: 5.214

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.