[A retrospective study on the application of cemented polyethylene liner technique in hip revision].

Zhichen Li1, Weijie Lu2, Jie Zhao3, Yi Chen1, Dongfeng Chen1, Chong Zheng1.   

Abstract

Objective: To evaluate the effectiveness of cemented polyethylene liner technique in hip revision.
Methods: Based on inclusion criteria, the clinical data of 26 patients who were undergone hip revision between January 2011 and December 2013, were retrospectively reviewed. Among them, 14 cases were treated with isolated liner exchange (group A) and 12 cases were treated with cemented polyethylene liner technique (group B). There was no significant difference in gender, age, the time from primary total hip arthroplasty to revision, and the preoperative Harris score between 2 groups ( P>0.05). The post-operative Harris score and complications were compared between 2 groups, and X-ray findings of the hip joint were recorded to review the position of hip components.
Results: All patients were followed up 4.4-6.4 years (mean, 5.4 years). Except for two femoral fractures during the revision (1 in each group), there was no other complication in 2 groups. The hip pain relieved and the lame gait corrected in 2 groups. The hip's function of 2 groups improved gradually after operation, with a better Harris score at 3 months and the best at the last follow-up, compared with preoperative scores ( P<0.05). There was no significant difference in Harris score at difference time points after operation between 2 group ( P>0.05). X-ray films showed no dislocation, aseptic loosening, and other interface related complication.
Conclusion: For the cases without the chance to do change liner, cemented polyethylene liner technique has a good effectiveness. But restrict patient selection should be considered before hip revision.

Entities:  

Keywords:  Total hip arthroplasty; cemented polyethylene liner technique; hip revision

Mesh:

Substances:

Year:  2018        PMID: 30129331     DOI: 10.7507/1002-1892.201803071

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  1 in total

1.  Study on the Application Value of CT Thin-Layer Scan Data Assisted 3D Printing Technology in Hip and Knee Replacement.

Authors:  Shihua Sun; Yongbin Xi; Xingchen Shi; Li Zhao; Fuming Ma; Jifang Qian
Journal:  J Healthc Eng       Date:  2021-09-27       Impact factor: 2.682

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.