Concentration and type of bioaerosols before and after conventional disinfection and sterilization procedures inside hospital operating rooms.

Mansooreh Dehghani1, Armin Sorooshian2, Shahrokh Nazmara3, Abbas Norouzian Baghani4, Mahdieh Delikhoon5.   

Abstract

Operating rooms (ORs) in hospitals are sensitive wards because patients can get infections. This work aimed to characterize the type and concentration of bioaerosols in nine ORs of an educational hospital before and after sterilization and disinfection. During 2017, fungal samples were incubated at 25-28 °C for 3-7 days and bacterial samples at 37 °C for 24-48 h. The study results showed that the concentrations of fungi before cleaning procedures (for both of disinfection and sterilization) were limited from 4.83 to 18.40 CFU/m3 and after cleaning procedures ranged from 1.90 to 8.90 CFU/m3. In addition, the concentrations of bacteria before cleaning procedures were limited 14.65-167.40 CFU/m3 and after cleaning procedures ranged from 9.50 to 38.40 CFU/m3. The difference between the mean concentrations of airborne bioaerosols before and after sterilization was significantly different than the suggested value of 30 CFU/m3 (p ≤ 0.05). The bacterial concentration was higher than the recommended value (30 CFU/m3) in 41% of the ORs. The main fungal species identified in the indoor air of ORs (before vs. after sterilization) were A. fumigatus (25.6 vs. 18.3%), A. Niger (11.6 vs. 5.8%), Penicillium spp. (5.5 vs. 3.3%), Alternaria spp. (2.8 vs. 0.7%), Fusarium spp. (9.7 vs. 3.7%), Mucor spp. (15 vs. 12.7%), Cephalotrichum spp. (1.7 vs. 0.8%), A. Flavus (24.6 vs. 18.5%), Cladosporium spp. (2.6 vs. 0.8%), and Trichoderma spp. (0 vs. 0.9%). The growth of biological species even after sterilization and disinfection likely resulted from factors including poor ventilation, sweeping of OR floors, inadequate HVAC filtration, high humidity, and also lack of optimum management of infectious waste after surgery. Designing well-constructed ventilation and air-conditioning systems, replacing HEPA filters, implementing more stringent, frequent, and comprehensive disinfection procedures, and controlling temperature and humidity can help decrease bioaerosols in ORs.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bioaerosol; Indoor air; Operating room; Shiraz; Sterilization

Mesh:

Substances:

Year:  2018        PMID: 30121503      PMCID: PMC6151147          DOI: 10.1016/j.ecoenv.2018.08.034

Source DB:  PubMed          Journal:  Ecotoxicol Environ Saf        ISSN: 0147-6513            Impact factor:   6.291


  22 in total

1.  Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: an experimental study.

Authors:  B Friberg; S Friberg; L G Burman
Journal:  J Hosp Infect       Date:  1999-05       Impact factor: 3.926

2.  Monitoring air sampling in operating theatres: can particle counting replace microbiological sampling?

Authors:  A Landrin; A Bissery; G Kac
Journal:  J Hosp Infect       Date:  2005-09       Impact factor: 3.926

3.  Bioaerosol characteristics in hospital clean rooms.

Authors:  Chih-Shan Li; Po-An Hou
Journal:  Sci Total Environ       Date:  2003-04-15       Impact factor: 7.963

4.  [Bacterial contamination of the air in different operating rooms].

Authors:  A Audurier; A Fenneteau; R Rivière; A Raoult
Journal:  Rev Epidemiol Sante Publique       Date:  1985       Impact factor: 1.019

5.  Long-term surveillance of air quality in medical center operating rooms.

Authors:  Gwo-Hwa Wan; Feng-Fang Chung; Chin-Sheng Tang
Journal:  Am J Infect Control       Date:  2011-01-22       Impact factor: 2.918

6.  Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC).

Authors:  Lynne Sehulster; Raymond Y W Chinn
Journal:  MMWR Recomm Rep       Date:  2003-06-06

7.  Fungal pollution of indoor environments and its management.

Authors:  A A Haleem Khan; S Mohan Karuppayil
Journal:  Saudi J Biol Sci       Date:  2012-06-15       Impact factor: 4.219

Review 8.  Environmental controls in operating theatres.

Authors:  S Dharan; D Pittet
Journal:  J Hosp Infect       Date:  2002-06       Impact factor: 3.926

9.  Assessment of the levels of airborne bacteria, Gram-negative bacteria, and fungi in hospital lobbies.

Authors:  Dong-Uk Park; Jeong-Kwan Yeom; Won Jae Lee; Kyeong-Min Lee
Journal:  Int J Environ Res Public Health       Date:  2013-01-31       Impact factor: 3.390

10.  Fungal air quality in hospital rooms: a case study in Tehran, Iran.

Authors:  Faramarz Azimi; Kazem Naddafi; Ramin Nabizadeh; Mohammad Sadegh Hassanvand; Mahmood Alimohammadi; Shirin Afhami; Seyed Nejat Musavi
Journal:  J Environ Health Sci Eng       Date:  2013-12-19
View more
  8 in total

1.  Microbiological analysis of bacterial and fungal bioaerosols from burn hospital of Yazd (Iran) in 2019.

Authors:  Akram Montazeri; Hengamah Zandi; Fahimeh Teymouri; Zahra Soltanianzadeh; Sara Jambarsang; Mehdi Mokhtari
Journal:  J Environ Health Sci Eng       Date:  2020-09-17

2.  Impact of a New Portable Air Purification Technology Device in the Pediatric Hospital Setting - A Pre-post Assessment Study.

Authors:  Nikhil G Rao; Ambuj Kumar; Chelsea Colon; D Y Goswami
Journal:  Cureus       Date:  2020-03-27

3.  Simultaneous monitoring of SARS-CoV-2, bacteria, and fungi in indoor air of hospital: a study on Hajar Hospital in Shahrekord, Iran.

Authors:  Sara Hemati; Gholam Reza Mobini; Mohsen Heidari; Fereidoun Rahmani; Akbar Soleymani Babadi; Marzieh Farhadkhani; Heshmatollah Nourmoradi; Ahmad Raeisi; Ali Ahmadi; Abbas Khodabakhshi; Mehraban Sadeghi; Milad Bagheri; Majid Validi; Simin Taghipour; Fazel Mohammadi-Moghadam
Journal:  Environ Sci Pollut Res Int       Date:  2021-04-10       Impact factor: 4.223

4.  Effect of Ozone Gas on Removal of Airborne Particles.

Authors:  Priscilla Alvarenga Agra; Patricia Alvarenga Agra; Marilia Fagury Videira Marceliano-Alves; Greice Maria Silva da Conceição; Sérgio Luiz de Lima Assumpção; Celso de Farias Crespo; Letícia Maria Borsarini Philippi; Renata Ximenes Lins
Journal:  Eur J Dent       Date:  2022-04-18

5.  Airborne fungal and bacterial microbiome in classrooms of elementary schools during the COVID-19 pandemic period: Effects of school disinfection and other environmental factors.

Authors:  Jun I L Yang; Bong Gu Lee; Ju-Hyeong Park; Min-Kyeong Yeo
Journal:  Indoor Air       Date:  2022-09       Impact factor: 6.554

Review 6.  Alternative Methods of Sterilization in Dental Practices Against COVID-19.

Authors:  Enzo Cumbo; Giuseppe Gallina; Pietro Messina; Giuseppe Alessandro Scardina
Journal:  Int J Environ Res Public Health       Date:  2020-08-08       Impact factor: 3.390

7.  A systematic review and meta-analysis of indoor bioaerosols in hospitals: The influence of heating, ventilation, and air conditioning.

Authors:  Rongchen Dai; Shan Liu; Qiushuang Li; Hanting Wu; Li Wu; Conghua Ji
Journal:  PLoS One       Date:  2021-12-23       Impact factor: 3.240

8.  Environmental sanitation and hygiene of elderly workers in Nakhon Si Thammarat Province, Thailand.

Authors:  Jira Kongpran; Chamnong Thanapop; Udomratana Vattanasit
Journal:  J Prev Med Hyg       Date:  2021-04-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.