Literature DB >> 30121323

Diagnostic value of FDG-PET versus magnetic resonance imaging for detecting spondylitis: a systematic review and meta-analysis.

Yanlin Yin1, Xinwei Liu2, Xinming Yang3, Jie Guo2, Qiang Wang2, Lixing Chen4.   

Abstract

BACKGROUND CONTEXT: Spondylitis is a rare infection in bone requiring multiple diagnostic strategies for verification.
PURPOSE: This study aimed to compare the diagnostic values of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) and magnetic resonance imaging (MRI) in detecting spondylitis.
METHODS: Online PubMed, Embase, and Cochrane Library databases were systematically searched through September 2017 for studies comparing the diagnostic values of 18F-FDG-PET and MRI. The summary sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curve were calculated using Stata software. The ratio of these indexes between 18F-FDG-PET and MRI was also determined.
RESULTS: The summary results for 18F-FDG-PET were as follows: sensitivity=0.96 [95% confidence intervals (CI), 0.84-0.99]; specificity=0.90 (95% CI, 0.79-0.96); PLR=9.83 (95% CI, 4.39-22.03); NLR=0.05 (95% CI, 0.01-0.19); DOR=124.08 (95% CI, 39.04-394.34); and area under the SROC=0.97 (95% CI, 0.95-0.98). The summary sensitivity, specificity, PLR, NLR, DOR, and area under the SROC for MRI were 0.76 (95% CI, 0.65-0.84), 0.62 (95% CI, 0.45-0.77), 2.01 (95% CI, 1.36-2.98), 0.39 (95% CI, 0.27-0.56), 5.08 (95% CI, 2.66-9.69), and 0.77 (95% CI, 0.73-0.80), respectively. The summary results of sensitivity (p=.034), specificity (p=.006), PLR (p<.001), DOR (p<.001), and area under the SROC (p<.001) were higher in 18F-FDG-PET than in MRI. However, NLR (p=.003) was lower in 18F-FDG-PET than in MRI.
CONCLUSIONS: 18F-FDG-PET had a higher diagnostic value compared with MRI in detecting spondylitis.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  (18)F-fluorodeoxyglucose positron emission tomography; Diagnostic value; FDG-PET; MRI; Magnetic resonance imaging; Spondylitis

Mesh:

Substances:

Year:  2018        PMID: 30121323     DOI: 10.1016/j.spinee.2018.07.027

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  3 in total

Review 1.  Diagnostic performance of 18F-FDG PET/CT in patients with spinal infection: a systematic review and a bivariate meta-analysis.

Authors:  Giorgio Treglia; Mariarosa Pascale; Elena Lazzeri; Wouter van der Bruggen; Roberto C Delgado Bolton; Andor W J M Glaudemans
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-11-15       Impact factor: 9.236

Review 2.  Diagnostic Performance of 18F-FDG PET/CT in Infectious and Inflammatory Diseases according to Published Meta-Analyses.

Authors:  Giorgio Treglia
Journal:  Contrast Media Mol Imaging       Date:  2019-07-25       Impact factor: 3.161

Review 3.  Bone and Joint Infections: The Role of Imaging in Tailoring Diagnosis to Improve Patients' Care.

Authors:  Andrea Sambri; Paolo Spinnato; Sara Tedeschi; Eleonora Zamparini; Michele Fiore; Riccardo Zucchini; Claudio Giannini; Emilia Caldari; Amandine Crombé; Pierluigi Viale; Massimiliano De Paolis
Journal:  J Pers Med       Date:  2021-12-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.