Literature DB >> 30121280

Commissural Alignment of Bioprosthetic Aortic Valve and Native Aortic Valve Following Surgical and Transcatheter Aortic Valve Replacement and its Impact on Valvular Function and Coronary Filling.

Andreas Fuchs1, Klaus F Kofoed1, Sung-Han Yoon2, Yannick Schaffner3, Gintautas Bieliauskas4, Hans Gustav Thyregod4, Raj Makkar2, Lars Søndergaard4, Ole De Backer4, Vinayak Bapat5.   

Abstract

OBJECTIVES: The aim of this study was to assess the commissural alignment between bioprosthetic and native aortic valve leaflets following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) and to investigate its impact on valvular function and coronary filling.
BACKGROUND: Expansion and geometry have been shown to affect leaflets of implanted transcatheter aortic bioprosthesis, but commissural alignment has not been studied.
METHODS: Pre- and post-procedural multidetector computed tomography (MDCT) of 28 SAVR patients and 212 TAVR patients were analyzed. Commissural alignment between the bioprosthetic (post) and native (pre) aortic valves was categorized as aligned (0° to 15° angle deviation) or as mild (15° to 30°), moderate (30° to 45°), or severe (45° to 60°) commissural misalignment (CMA).
RESULTS: With SAVR, 27 of 28 cases (96%) were aligned and 1 had mild CMA. For all types of transcatheter heart valves (THVs), there was random valve implantation with regard to commissural alignment: 22% of THVs were aligned, 25% had mild CMA, 22% had moderate CMA, and 31% had severe CMA. The degree of commissural alignment was not associated with a difference in transvalvular gradient, paravalvular aortic regurgitation, or simulated coronary filling. However, there was a significantly higher rate of mild central aortic regurgitation in those THVs with moderate or greater CMA compared with those THV with mild or less CMA (7.8% vs. 1.1%; p = 0.03).
CONCLUSIONS: Commissural alignment is excellent in case of SAVR but random in case of TAVR. There is no association between CMA and transvalvular gradient or coronary filling; however, there is a significantly higher rate of mild central aortic regurgitation in case of moderate or greater CMA.
Copyright © 2018. Published by Elsevier Inc.

Entities:  

Keywords:  aortic stenosis; aortic valve replacement; computed tomography; surgical; transcatheter

Mesh:

Year:  2018        PMID: 30121280     DOI: 10.1016/j.jcin.2018.05.043

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  8 in total

1.  Patient-Specific Immersed Finite Element-Difference Model of Transcatheter Aortic Valve Replacement.

Authors:  Jordan A Brown; Jae H Lee; Margaret Anne Smith; David R Wells; Aaron Barrett; Charles Puelz; John P Vavalle; Boyce E Griffith
Journal:  Ann Biomed Eng       Date:  2022-10-20       Impact factor: 4.219

2.  Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid-structure interaction analysis.

Authors:  Ram P Ghosh; Gil Marom; Matteo Bianchi; Karl D'souza; Wojtek Zietak; Danny Bluestein
Journal:  Biomech Model Mechanobiol       Date:  2020-02-24

3.  A patient-specific algorithm to achieve commissural alignment with Acurate Neo: The sextant technique.

Authors:  Federico De Marco; Matteo Casenghi; Pietro Spagnolo; Antonio Popolo Rubbio; Nedy Brambilla; Luca Testa; Francesco Bedogni
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-07       Impact factor: 2.585

Review 4.  Percutaneous access to coronary arteries in patients after transcatheter aortic valve implantation procedures - is it a real problem?

Authors:  Piotr Chodór; Krzysztof Wilczek; Roman Przybylski; Jerzy Nożyński; Łukasz Włoch; Zbigniew Kalarus
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-09-18       Impact factor: 1.426

Review 5.  Transcatheter Bioprosthetic Aortic Valve Dysfunction: What We Know So Far.

Authors:  Fadi Sawaya; Troels H Jørgensen; Lars Søndergaard; Ole De Backer
Journal:  Front Cardiovasc Med       Date:  2019-10-04

6.  Current challenges in TAVI: neo-commissural alignment to mimic more physiologic valve implantation.

Authors:  Aditya Sengupta; Sophia L Alexis; Jason C Kovacic; Gilbert H L Tang
Journal:  Vessel Plus       Date:  2020-12-10

Review 7.  Commissural alignment in transcatheter aortic valve replacement: A literature review.

Authors:  Abdul Muiz Khalid; Crochan J O'Sullivan
Journal:  Front Cardiovasc Med       Date:  2022-08-09

8.  Complexity assessment and technical aspect of coronary angiogram and percutaneous coronary intervention following transcatheter aortic valve implantation.

Authors:  Nils Perrin; Amir Fassa; Antoine Baroz; Caroline Frangos; Stephane Mock; Angela Frei; Murat Cimci; Sophie Degrauwe; Marco Roffi; Juan Fernando Iglesias; Stephane Noble
Journal:  Cardiol J       Date:  2020-05-21       Impact factor: 2.737

  8 in total