Literature DB >> 30120749

The influence of anthropometric and basic circulatory variables on count rate in cadmium-zinc-telluride SPECT gated radionuclide angiography.

Julie Rydberg1, Jannick Andersen2, Christian Haarmark2, Bo Zerahn2.   

Abstract

AIM: To determine the influence of weight, height, gender, age, heart rate, and blood pressure on count rate in cadmium-zinc-telluride single-photon emission computed tomography (CZT SPECT) gated radionuclide angiography.
METHOD: A total of 1,065 eligible patients referred for routine assessment of left ventricular ejection fraction were registered from August 2015 to November 2016. Data were recorded on heart rate, systolic and diastolic blood pressure, age, gender, height, weight, and count rate. All radionuclide angiographies were performed on a dedicated cardiac CZT SPECT camera, GE Discovery 530c. A dose of 550 MBq 99mTc-labeled human serum albumin was administered intravenously to each patient.
RESULTS: Count rate varied from 1.2 to 8.9 counts per second. All test variables were significantly associated with count rate. From the preliminary analysis, weight appeared as the main contributing factor for explaining the variations in count rate with and R2 of 0.68. A model consisting of weight, height, gender, and age explains 75% of the variance in count rate.
CONCLUSION: Patient height, weight, gender, and age have significant impact on count rate when performing CZT radionuclide angiography and may subsequently be used for individualized planning of tracer dosage.

Entities:  

Keywords:  Gated SPECT; RNA; count rate

Mesh:

Substances:

Year:  2018        PMID: 30120749     DOI: 10.1007/s12350-018-1402-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  1 in total

1.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

  1 in total
  3 in total

1.  Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data.

Authors:  Hubert Tissot; Véronique Roch; Olivier Morel; Nicolas Veran; Mathieu Perrin; Marine Claudin; Antoine Verger; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-27       Impact factor: 5.952

2.  Cardiac CZT-SPECT: More than left ventricular imaging.

Authors:  Bo Zerahn; Christian Haarmark
Journal:  J Nucl Cardiol       Date:  2021-06-24       Impact factor: 3.872

3.  An Algorithm for Individual Dosage in Cadmium-Zinc-Telluride SPECT-Gated Radionuclide Angiography.

Authors:  Maria Normand Hansen; Christian Haarmark; Bent Kristensen; Bo Zerahn
Journal:  Diagnostics (Basel)       Date:  2021-12-04
  3 in total