Literature DB >> 30119065

Comparison of Navigator Triggering Reduced Field of View and Large Field of View Diffusion-Weighted Imaging of the Pancreas.

Lorenzo Mannelli, Serena Monti1, Giuseppe Corrias, Maggie M Fung2, Charles Nyman, Jennifer S Golia Pernicka, Richard K G Do.   

Abstract

RATIONALE AND
OBJECTIVES: The purpose of this study is to compare image quality, presence and grade of artifacts, signal-to-noise ratio, and apparent diffusion coefficient (ADC) values in pancreatic tissue between high-resolution navigator-triggered (NT) restricted field of view (rFOV) FOCUS single-shot (SS) echo-planar imaging (EPI) diffusion-weighted imaging (DWI) and NT large FOV SS-EPI DWI.
MATERIALS AND METHODS: Magnetic resonance imaging examinations were performed with GE 3-T systems using a 32-channel body array coil. Seventeen consecutive patients were imaged. A 5-point scale semiquantitative grading system was used to evaluate image quality and general artifacts. Signal-to-noise ratio and ADC were measured in the head, body, and tail of the pancreas. Statistical analysis was performed using Student t test and Wilcoxon signed rank test, with differences considered significant for P value less than 0.05.
RESULTS: More artifacts were present on large FOV compared with rFOV FOCUS SS-EPI DW images (P < 0.01). Restricted field of view image quality was subjectively better (P < 0.01). No difference in the signal-to-noise ratio was demonstrated between the 2 image datasets. Apparent diffusion coefficient values were significantly lower (P < 0.01) when calculated from rFOV images than large FOV images.
CONCLUSIONS: Our results demonstrate better image quality and reduced artifacts in rFOV images compared with large FOV DWI. Measurements from ADC maps derived from rFOV DWI show significantly lower ADC values when compared with ADC maps derived from large FOV DWI.

Entities:  

Mesh:

Year:  2019        PMID: 30119065      PMCID: PMC6331255          DOI: 10.1097/RCT.0000000000000778

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

1.  Reproducibility and feasibility of optic nerve diffusion MRI techniques: single-shot echo-planar imaging (EPI), readout-segmented EPI, and reduced field-of-view diffusion-weighted imaging.

Authors:  Fanglu Zhou; Qing Li; Xiaohui Zhang; Hongli Ma; Ge Zhang; Silin Du; Lijun Zhang; Thomas Benkert; Zhiwei Zhang
Journal:  BMC Med Imaging       Date:  2022-05-24       Impact factor: 2.795

2.  The value of whole-lesion histogram analysis based on field‑of‑view optimized and constrained undistorted single shot (FOCUS) DWI for predicting axillary lymph node status in early-stage breast cancer.

Authors:  Shu Fang; Jun Zhu; Yafeng Wang; Jie Zhou; Guiqian Wang; Weiwei Xu; Wei Zhang
Journal:  BMC Med Imaging       Date:  2022-09-10       Impact factor: 2.795

3.  Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T.

Authors:  Wenguang Liu; Hui Liu; Simin Xie; Ismail Bilal Masokano; Yu Bai; Xiao Wang; Linhui Zhong; Yi Wu; Jilin Nie; Gaofeng Zhou; Yigang Pei; Wenzheng Li
Journal:  Sci Rep       Date:  2022-07-20       Impact factor: 4.996

4.  Evaluating the Histopathology of Pancreatic Ductal Adenocarcinoma by Intravoxel Incoherent Motion-Diffusion Weighted Imaging Comparing With Diffusion-Weighted Imaging.

Authors:  Qi Liu; Jinggang Zhang; Man Jiang; Yue Zhang; Tongbing Chen; Jilei Zhang; Bei Li; Jie Chen; Wei Xing
Journal:  Front Oncol       Date:  2021-06-23       Impact factor: 6.244

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.