Literature DB >> 30115570

Use of Intra-aortic Balloon Pump as a Bridge to Heart Transplant in Spain: Results From the ASIS-TC Study.

Eduardo Barge-Caballero1, Francisco González-Vílchez2, Juan F Delgado3, Sonia Mirabet-Pérez4, José González-Costello5, Félix Pérez-Villa6, Manuel Martínez-Sellés7, Javier Segovia-Cubero8, Daniela Hervás-Sotomayor9, Teresa Blasco-Peiró10, Luis De la Fuente-Galán11, José Luis Lambert-Rodríguez12, Diego Rangel-Sousa13, Luis Almenar-Bonet14, Iris P Garrido-Bravo15, Gregorio Rábago-Juan-Aracil16, Javier Muñiz17, María G Crespo-Leiro18.   

Abstract

INTRODUCTION AND
OBJECTIVES: In Spain, intra-aortic balloon pump (IABP) has been used frequently as a bridge to urgent heart transplant (HT). We sought to analyze the clinical outcomes of this strategy.
METHODS: We conducted a case-by-case, retrospective review of clinical records of 281 adult patients listed for urgent HT under IABP support in 16 Spanish institutions from 2010 to 2015. Pre- and post-transplant survival and adverse clinical events were analyzed.
RESULTS: A total of 194 (69%, 95%CI, 63.3-74.4) patients were transplanted and 20 (7.1%, 95%CI, 4.4-10.8) died during a mean period of IABP support of 10.9±9.7 days. IABP support was withdrawn before an organ became available in 32 (11.4%) patients. Thirty-five (12.5%, 95%CI, 8.8-16.9) patients transitioned from IABP to full-support mechanical devices. Mean urgent waiting list time increased from 5.9±6.3 days in 2010 to 15±11.7 days in 2015 (P=.001). Post-transplant survival rates at 30-days, 1-year, and 5-years were 88.1% (95%CI, 85.7-90.5), 76% (95%CI, 72.9-79.1), and 67.8% (95%CI, 63.7-71.9), respectively. The incidence rate of major adverse clinical outcomes-device dysfunction, stroke, bleeding or infection-during IABP support was 26 (95%CI, 20.6-32.4) episodes per 1000 patient-days. The incidence rate of IABP explantation due to complications was 7.2 (95%CI, 4.5-10.8) cases per 1000 patient-days.
CONCLUSIONS: In a setting of short waiting list times, IABP can be used to bridge candidates to urgent HT with acceptable postoperative results, but there were significant rates of adverse clinical events during support.
Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Asistencia circulatoria mecánica; Balón de contrapulsación intraaórtico; Heart transplant; Intra-aortic balloon pump; Mechanical circulatory support; Trasplante cardiaco

Year:  2018        PMID: 30115570     DOI: 10.1016/j.rec.2018.07.003

Source DB:  PubMed          Journal:  Rev Esp Cardiol (Engl Ed)        ISSN: 1885-5857


  1 in total

1.  The Man with 2 Hearts: 25 Years from Heterotopic to Orthotopic Heart Transplantation.

Authors:  Elizabeth L Godfrey; Michael L Kueht; Abbas Rana; O H Frazier
Journal:  Tex Heart Inst J       Date:  2019-06-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.