Literature DB >> 30114702

Reproducibility and Clinical Correlates of Supine Diaphragmatic Motion Measured by M-Mode Ultrasonography in Healthy Volunteers.

Simone Scarlata, Damiana Mancini, Alice Laudisio, Augusto Benigni, Raffaele Antonelli Incalzi.   

Abstract

BACKGROUND: Assessing diaphragm mobility is important to detect malfunctions or impending exhaustion and to evaluate the effects of many chest and abdominal conditions on respiratory mechanics. Amongst several imaging methods, ultrasonography represents the only noninvasive, nonionizing imaging technique widely available for the direct assessment of diaphragm excursion.
OBJECTIVES: the aim of this study is to prospectively assess the supine diaphragmatic motion amplitude, intra- and inter-observer agreement, and anthropometric correlates of diaphragm motion variability, measured through M-mode ultrasonography, in a sample of healthy volunteers.
METHODS: One-hundred healthy volunteers were considered eligible for the study. Instead of B-mode imaging, the M-mode technique was used to achieve a more accurate measurement of diaphragm motion. To assess intra-observer variability, 3 consecutive measurements (M-mode and B-mode) of the right dome motion were obtained at every session. To test for inter-rater reliability, the subjects were asked to provide 2 more diaphragm motion measurements every week, each performed by 2 experienced operators, and 42 subjects accepted.
RESULTS: Diaphragmatic motion was positively correlated with height and weight both at quiet (Spearman's coefficient = 0.514, p < 0.001 and 0.314, p = 0.038) and deep breathing (Spearman's coefficient = 0.342, p = 0.001 and 0.225, p = 0.024, respectively) and negatively correlated with age, but only during deep breathing (Spearman's coefficient = -0.272, p = 0.006). Intra-observer agreement degree on all 3 measurements was excellent during both quiet and deep breathing, with a Cronbach's alpha of 0.793 and 0.901, respectively, and an intra-class coefficient of 0.797 and 0.900, respectively. Similarly, the degree of inter-observer agreement achieved a Cronbach's alpha of 0.638 and 0.776, and an inter-class coefficient of 0.632 and 0.778, respectively. Deep breathing was associated with sex only in linear multivariable models (B = -10.14; 95% confidence interval [CI] -17.86, -2.41; p = 0.011), while quiet breathing resulted to be affected by height only (B = 30.05; 95% CI 0.79-59.31; p = 0.044).
CONCLUSIONS: Diaphragm excursion measurements using the M-mode technique were accurate and could be reproduced also when obtained in recumbent patients. After adjustments, the main predictors of diaphragmatic motion were sex and height, which should be considered to design a specifically tailored study and to develop normality reference equations.
© 2018 S. Karger AG, Basel.

Entities:  

Keywords:  Deep breathing; Diaphragmatic motion M-mode ultrasonography; Inter-observer agreement; Intra-observer agreement; Quiet breathing

Mesh:

Year:  2018        PMID: 30114702     DOI: 10.1159/000489229

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  11 in total

1.  Intrarater Reliability of Diaphragm Excursion and Resting Thickness Using Ultrasound Imaging in Subjects With Nonspecific Chronic Low Back Pain.

Authors:  Maryam Ziaeifar; Shohreh Noorizadeh Dehkordi; Hamid Reza Haghighatkhah; Javad Sarrafzadeh; Amir Masoud Arab; Alieh Zendehdel Jadehkenari
Journal:  J Chiropr Med       Date:  2022-04-21

2.  Diaphragmatic thickness and excursion by lung ultrasound in pediatric chronic pulmonary diseases.

Authors:  Sally R Ishak; Hossam M Sakr
Journal:  J Ultrasound       Date:  2021-02-18

Review 3.  Assessment of diaphragmatic function by ultrasonography: Current approach and perspectives.

Authors:  Alain Boussuges; Sarah Rives; Julie Finance; Fabienne Brégeon
Journal:  World J Clin Cases       Date:  2020-06-26       Impact factor: 1.337

4.  Diaphragm sniff ultrasound: Normal values, relationship with sniff nasal pressure and accuracy for predicting respiratory involvement in patients with neuromuscular disorders.

Authors:  Abdallah Fayssoil; Lee S Nguyen; Adam Ogna; Tanya Stojkovic; Paris Meng; Dominique Mompoint; Robert Carlier; Helene Prigent; Bernard Clair; Anthony Behin; Pascal Laforet; Guillaume Bassez; Pascal Crenn; David Orlikowski; Djillali Annane; Bruno Eymard; Frederic Lofaso
Journal:  PLoS One       Date:  2019-04-24       Impact factor: 3.240

5.  Assessment of peripheral muscle thickness and architecture in healthy volunteers using hand-held ultrasound devices; a comparison study with standard ultrasound.

Authors:  Peter Turton; Richard Hay; Ingeborg Welters
Journal:  BMC Med Imaging       Date:  2019-08-19       Impact factor: 1.930

Review 6.  Ultrasound and non-ultrasound imaging techniques in the assessment of diaphragmatic dysfunction.

Authors:  Franco A Laghi; Marina Saad; Hameeda Shaikh
Journal:  BMC Pulm Med       Date:  2021-03-15       Impact factor: 3.317

7.  Diaphragmatic excursion by ultrasound: reference values for the normal population; a cross-sectional study in Egypt.

Authors:  Ahmed E Kabil; Eman Sobh; Mahmoud Elsaeed; Houssam Eldin Hassanin; Ibrahim H Yousef; Heba H Eltrawy; Ahmed M Ewis; Ahmed Aboseif; AbdAllah M Albalsha; Sawsan Elsawy; Abdul Rahman H Ali
Journal:  Multidiscip Respir Med       Date:  2022-06-01

8.  Diaphragmatic Rapid Shallow Breathing Index: A Simple Tool to Give more Power to Predict Weaning?

Authors:  Riddhi Kundu; Shrikanth Srinivasan
Journal:  Indian J Crit Care Med       Date:  2022-09

Review 9.  Diaphragm Ultrasound in Cardiac Surgery: State of the Art.

Authors:  Abdallah Fayssoil; Nicolas Mansencal; Lee S Nguyen; David Orlikowski; Hélène Prigent; Jean Bergounioux; Djillali Annane; Frédéric Lofaso
Journal:  Medicines (Basel)       Date:  2022-01-11

10.  Prediction of Loss of Muscle Mass in Sarcopenia Using Ultrasonic Diaphragm Excursion.

Authors:  Bin Zeng; Shaochong He; Hao Lu; Guiyin Liang; Xiaosong Ben; Wenzhao Zhong; Mingsheng Zhang; Hao Wang
Journal:  Contrast Media Mol Imaging       Date:  2021-12-06       Impact factor: 3.161

View more