Literature DB >> 30113735

Classification and cyclic fatigue evaluation of new kinematics for endodontic instruments.

Gianluca Gambarini1, Lucila Piasecki2, Gabriele Miccoli1, Gianfranco Gaimari1, Roberto Di Giorgio1, Dario Di Nardo1, Adham A Azim2, Luca Testarelli1.   

Abstract

This study evaluated the effect of new motions of the motor TriAuto ZX2 on the cyclic fatigue of endodontic instruments. Vortex Blue 35.06 instruments were divided into four groups (n = 10) and tested for fatigue in a curved artificial canal (90° and 2 mm radius) using the following motions: continuous rotation (CR), Optimum Torque Reverse (OTR) set at 180° and the Optimum Glide Path (OGP), which was tested at 90° and 240°. The time to fracture (TTF) and the lengths of the fractured fragments were recorded. The mean TTF was significantly different among the groups (anova, P < 0.05): OGP 90° (213.39 ± 27.45), OTR 180° (121.24 ± 17.03), OGP 240° (45.24 ± 5.61) and CR (8.43 ± 1.27). Weibull analysis confirmed the shortest life expectancy for CR and the longest survival for OGP at 90°. The resistance to fatigue was affected by motions and pre-set angles. The proprietary movements that are currently available for endodontic instruments were classified according to their kinematics.
© 2018 Australian Society of Endodontology Inc.

Entities:  

Keywords:  Optimum Glide Path motion; Optimum Torque Reverse motion; continuous rotation; cyclic fatigue; endodontic file motions; reciprocation

Mesh:

Substances:

Year:  2018        PMID: 30113735     DOI: 10.1111/aej.12294

Source DB:  PubMed          Journal:  Aust Endod J        ISSN: 1329-1947            Impact factor:   1.659


  5 in total

1.  Mechanical Properties of the New Generation RACE EVO and R-Motion Nickel-Titanium Instruments.

Authors:  Fatima Betul Basturk; Taha Özyürek; Gülşah Uslu; Mustafa Gündoğar
Journal:  Materials (Basel)       Date:  2022-05-06       Impact factor: 3.748

2.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

3.  Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire.

Authors:  Gianluca Gambarini; Massimo Galli; Dario Di Nardo; Marco Seracchiani; Orlando Donfrancesco; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-07-01

4.  Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel-Titanium Instruments.

Authors:  Satoshi Omori; Arata Ebihara; Keiko Hirano; Yuka Kasuga; Hayate Unno; Taro Nakatsukasa; Shunsuke Kimura; Keiichiro Maki; Takao Hanawa; Takashi Okiji
Journal:  Materials (Basel)       Date:  2022-10-02       Impact factor: 3.748

5.  Comparison of canal transportation and centering ability of manual K-files and reciprocating files in glide path preparation: a micro-computed tomography study of constricted canals.

Authors:  Jing-Yi Liu; Zhi-Xiong Zhou; Wei-Ju Tseng; Bekir Karabucak
Journal:  BMC Oral Health       Date:  2021-02-23       Impact factor: 2.757

  5 in total