Literature DB >> 30106343

Target Size Variation in Microdosimetric Distributions and its Impact on the Linear-Quadratic Parameterization of Cell Survival.

Fernanda Villegas1, Nina Tilly1,2, Anders Ahnesjö1.   

Abstract

The linear-quadratic (LQ) parameterization of survival fraction [SF( D)] inherently assumes that all cells in a population receive the same dose ( D), albeit the distribution of specific energy z over the individual cells f( z, D) can be very wide. From these microdosimetric distributions, which are target size dependent, we estimate the size of the cellular sensitive volume by analyzing its influence on the LQ parameterization of cell survival. A Monte Carlo track structure code was used to simulate detailed tracks from a 60Co source as well as proton and carbon ions of various energies. From these tracks, f( z, D) distributions were calculated for spherical targets with diameters ranging from 10 nm to 12 μm. A cell survival function based on f( z, D) was fitted to experimental LQ α values, revealing an intrinsic limitation that target size imposes on the usage of f( z, D) to describe the linear term of the LQ parameterization. The results indicate that such threshold volume arises naturally from the relationship between the particle's probability of no-hit and the probability of cell survival. Further analysis led to the proposal of a radiobiological property [Formula: see text], defined as the mean lineal energy corresponding to the target size that allows equivalence between the mean inactivation dose (MID) and the mean specific energy [Formula: see text]. The fact that [Formula: see text] is an increasing continuous function of target size within the range of biological targets of interest in radiobiology, ensures the uniqueness of [Formula: see text] for any radiation quality, thus, its potential usefulness in modeling. In conclusion, an accurate estimation of such threshold volumes may be useful for improving modeling of cell survival curves.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30106343     DOI: 10.1667/RR15089.1

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  2 in total

1.  Systematic microdosimetric data for protons of therapeutic energies calculated with Geant4-DNA.

Authors:  Oleg N Vassiliev; Christine B Peterson; Wenhua Cao; David R Grosshans; Radhe Mohan
Journal:  Phys Med Biol       Date:  2019-11-04       Impact factor: 3.609

2.  Experimental validation of an analytical microdosimetric model based on Geant4-DNA simulations by using a silicon-based microdosimeter.

Authors:  A Bertolet; V Grilj; C Guardiola; A D Harken; M A Cortés-Giraldo; A Baratto-Roldán; A Carabe
Journal:  Radiat Phys Chem Oxf Engl 1993       Date:  2020-06-17       Impact factor: 2.858

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.