Literature DB >> 30105321

Multiplex sample-to-answer detection of bacteria using a pipette-actuated capillary array comb with integrated DNA extraction, isothermal amplification, and smartphone detection.

Junhou Hui1, Yin Gu, Yuanshou Zhu, Yanjing Chen, Shu-Juan Guo, Sheng-Ce Tao, Yan Zhang, Peng Liu.   

Abstract

A pipette-actuated capillary array comb (PAAC) system operated on a smartphone-based hand-held device has been successfully developed for the multiplex detection of bacteria in a "sample-to-answer" manner. The PAAC consists of eight open capillaries inserted into a cylindrical plastic base with a piece of chitosan-modified glass filter paper embedded in each capillary. During the sample preparation, a PAAC was mounted into a 1 mL pipette tip with an enlarged opening and was operated with a 1 mL pipette for liquid handling. The cell lysate was drawn and expelled through the capillaries three times to facilitate the DNA capture on the embedded filter discs. Following washes with water, the loop-mediated isothermal amplification (LAMP) reagents were aspirated into the capillaries, in which the primers were pre-fixed with chitosan. After that, the PAAC was loaded into the smartphone-based device for a one-hour amplification at 65 °C and end-point detection of calcein fluorescence in the capillaries. The DNA capture efficiency of a 1.1 mm-diameter filter disc was determined to be 97% of λ-DNA and the coefficient of variation among the eight capillaries in the PAAC was only 2.2%. The multiplex detection of genomic DNA extracted from Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus provided limits of detection of 200, 500, and 500 copies, respectively, without any cross-contamination and cross reactions. "Sample-to-answer" detection of E. coli samples was successfully completed in 85 minutes, demonstrating a sensitivity of 200 cfu per capillary. The multiplex "sample-to-answer" detection, the streamlined operation, and the compact device should facilitate a broad range of applications of our PAAC system in point-of-care testing.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30105321     DOI: 10.1039/c8lc00543e

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  8 in total

Review 1.  Interfacing Pathogen Detection with Smartphones for Point-of-Care Applications.

Authors:  Xiong Ding; Michael G Mauk; Kun Yin; Karteek Kadimisetty; Changchun Liu
Journal:  Anal Chem       Date:  2018-12-03       Impact factor: 6.986

2.  Modular micro-PCR system for the onsite rapid diagnosis of COVID-19.

Authors:  Phuong Quoc Mai Nguyen; Ming Wang; Nelisha Ann Maria; Adelicia Yongling Li; Hsih Yin Tan; Gordon Minru Xiong; Meng-Kwang Marcus Tan; Ali Asgar S Bhagat; Catherine W M Ong; Chwee Teck Lim
Journal:  Microsyst Nanoeng       Date:  2022-07-19       Impact factor: 8.006

3.  An ultraportable and versatile point-of-care DNA testing platform.

Authors:  Huan Xu; Anyue Xia; Dandan Wang; Yiheng Zhang; Shaoli Deng; Weiping Lu; Jie Luo; Qiu Zhong; Fengling Zhang; Lin Zhou; Wenqing Zhang; Yang Wang; Cheng Yang; Kai Chang; Weiling Fu; Jinhui Cui; Mingzhe Gan; Dan Luo; Ming Chen
Journal:  Sci Adv       Date:  2020-04-22       Impact factor: 14.136

4.  A Novel Microfluidic Device Integrated with Chitosan-Modified Capillaries for Rapid ZIKV Detection.

Authors:  Xinchao Zhu; Jun Zhao; Anzhong Hu; Jingyu Pan; Guoqing Deng; Changyi Hua; Cancan Zhu; Yong Liu; Ke Yang; Ling Zhu
Journal:  Micromachines (Basel)       Date:  2020-02-11       Impact factor: 2.891

5.  A Fully Integrated In Vitro Diagnostic Microsystem for Pathogen Detection Developed Using a "3D Extensible" Microfluidic Design Paradigm.

Authors:  Zhi Geng; Yin Gu; Shanglin Li; Baobao Lin; Peng Liu
Journal:  Micromachines (Basel)       Date:  2019-12-12       Impact factor: 2.891

Review 6.  Smartphone-Based Multiplexed Biosensing Tools for Health Monitoring.

Authors:  Tutku Beduk; Duygu Beduk; Mohd Rahil Hasan; Emine Guler Celik; Jurgen Kosel; Jagriti Narang; Khaled Nabil Salama; Suna Timur
Journal:  Biosensors (Basel)       Date:  2022-07-29

Review 7.  Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review.

Authors:  Thi Xoan Hoang; Le Minh Tu Phan; Thuy Anh Thu Vo; Sungbo Cho
Journal:  Biomedicines       Date:  2021-05-12

8.  Multiplex and visual detection of African Swine Fever Virus (ASFV) based on Hive-Chip and direct loop-mediated isothermal amplification.

Authors:  Yuan-Shou Zhu; Ning Shao; Jian-Wei Chen; Wen-Bao Qi; Yang Li; Peng Liu; Yan-Jing Chen; Su-Ying Bian; Yan Zhang; Sheng-Ce Tao
Journal:  Anal Chim Acta       Date:  2020-10-08       Impact factor: 6.558

  8 in total