Literature DB >> 30100865

Fracture and embolization of intravenous cannula placed in external jugular vein: A rare complication.

Chitta Ranjan Mohanty1, Ritesh Panda1.   

Abstract

Entities:  

Year:  2018        PMID: 30100865      PMCID: PMC6044146          DOI: 10.4103/sja.SJA_289_18

Source DB:  PubMed          Journal:  Saudi J Anaesth


× No keyword cloud information.
Sir, External jugular vein (EJV) is commonly used for venous manometer and catheterization when peripheral venous assess is difficult. Though central venous assess is the preferred method in emergency setting, sometimes, EJV is cannulated with 16G or 18G intravenous cannula and secured in place with the help of sterile dressing and a 3-way stopcock attached to prevent air migration. Catheter fracture and embolization is a rarely reported complication of central venous and peripherally inserted central venous cannula.[12] We report the first instance of intravenous cannula fracture in our institute placed in EJV and distal migration toward clavicle. Our patient is a 65-year-old female admitted in the Intensive Care Unit (ICU) and was inserted 18G cannula in the left EJV due to difficulty in obtaining peripheral venous assess and was to be removed by staff nurse at the time of patient discharge. During its removal, the catheter broke at its hub and it remained within the vein which was palpable. Due to late hours, exploration was planned the next day. There was gradual distal migration of the segment due to patient movement. Ultrasound could not detect the fractured segment. Computed tomography scan was done in which the fracture segment was visible in supraclavicular region at medial third of left clavicle [Figures 1 and 2]. The fractured segment was removed at the junction of thrombosed EJV and subclavian vein by surgical intervention (there was no interventional radiologist).[34]
Figure 1

Sagittal section showing position of foreign body (fractured canula) in relation to clavicle

Figure 2

Axial section showing foreign body in relation to clavicle

Sagittal section showing position of foreign body (fractured canula) in relation to clavicle Axial section showing foreign body in relation to clavicle Rupture and distal migration of intravenous cannula can occur when there is prolonged catheterization, poor quality of intravenous cannula, and Not careful while removing catheter. Health-care workers in ward, ICU, and emergency department should be aware of the complications of intravenous cannula fracture and migration. Proper care should be taken during removal of catheters placed in central veins to avoid potentially serious complication of catheter migration and, if occurs, immediate steps have to be taken.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  4 in total

1.  Treatment strategy in the fracture of an implanted central venous catheter.

Authors:  Lili Hayari; Sergey Yalonetsky; Avraham Lorber
Journal:  J Pediatr Hematol Oncol       Date:  2006-03       Impact factor: 1.289

2.  Percutaneous vascular foreign body retrieval: experience of an 11-year period.

Authors:  R F Dondelinger; B Lepoutre; J C Kurdziel
Journal:  Eur J Radiol       Date:  1991 Jan-Feb       Impact factor: 3.528

3.  [Intravascular rupture of a central venous catheter in a premature infant: retrieval by a nonsurgical technique].

Authors:  M F Courcoux; P Jouvet; D Bonnet; F Iserin; P Bonhoeffer
Journal:  Arch Pediatr       Date:  2000-03       Impact factor: 1.180

4.  Fracture and embolization of a peripherally inserted central venous catheter.

Authors:  D N Linz; G S Bisset; B W Warner
Journal:  JPEN J Parenter Enteral Nutr       Date:  1994 Jan-Feb       Impact factor: 4.016

  4 in total
  1 in total

1.  Point-of-care ultrasonography: a boon for early localization and retrieval of broken fragment of external jugular venous catheter.

Authors:  Chitta Ranjan Mohanty; Suma Rabab Ahmad; Anirudh Elyat; Snigdha Bellapukonda; Sourav Kumar Panigrahi
Journal:  Korean J Anesthesiol       Date:  2019-10-09
  1 in total